Product details
Product Overview
- The HORIBA STEC SEF-Z514MGX is a digital mass flow meter.
- It belongs to the SEF-Z500X series.
- It delivers fast and stable gas measurement.
- Response time is 1 second or less across the full range.
- The meter uses a variable PID system.
- It supports multi-range and multi-gas operation.
- Typical flow spans 10 SCCM to 50 SLM.
- DeviceNet protocol enables easy system integration.
- 316L stainless steel wetted parts resist corrosion.
- This meter suits semiconductor and industrial automation lines.
Technical Data
- Brand: HORIBA STEC
- Model: SEF-Z514MGX
- Series: SEF-Z500X / SEC-Z500X
- Product type: Digital mass flow meter (SEF series)
- Full-scale flow (N2): #R01 10 SCCM, #R1.5 17.5 SCCM, #01 30 SCCM, #1.5 55 SCCM, #02 100 SCCM, #2.5 175 SCCM, #03 300 SCCM, #3.5 550 SCCM, #04 1 SLM, #4.5 1.75 SLM, #05 3 SLM, #5.5 5.5 SLM, #06 10 SLM
- Measuring range: 0 to 100% of full scale
- Control range: 2 to 100% of full scale
- Accuracy: ±1.0% S.P. above 25% F.S.; ±0.25% F.S. at or below 25% F.S.
- Linearity: ≤ ±0.5% F.S.
- Repeatability: ≤ ±0.2% F.S.
- Response time: ≤ 1 second over full range
- Frequency response: Fast digital control loop; stable at ≤ 1 s step change
- Sensitivity: Detects flow changes down to 0.25% F.S. accuracy band
- Resolution: Full digital measurement; 0.1% F.S. typical output resolution
- Operating temperature: 5 to 50°C (recommended 15 to 45°C)
- Environmental resistance: Stable across 5–50°C; He leak integrity ≤ 5 × 10⁻¹² Pa·m³/s
- Anti-interference: DeviceNet digital protocol resists industrial noise
- Operating differential pressure: 50 to 300 kPa(d); #5.5 and #06: 100 to 300 kPa(d)
- Operating differential pressure (SEF): ≤ 300 kPa(d)
- Max operating pressure: 450 kPa(g)
- Pressure resistance: 1000 kPa(g)
- Fully closed valve flow: ≤ 2% F.S.
- Wetted materials: 316L stainless steel, polished surface
- Digital interface: DeviceNet™ protocol
- Power supply: DC 24 V, 4.0 VA, ODVA compliant
- Standard fitting: 1/4 inch VCR equivalent
- Fitting options: 1.125 inch IGS, 1.5 inch IGS
- Mounting orientation: Free
Installation Guide
- Mount the meter in any orientation.
- Keep the unit within 5 to 50°C.
- Use clean, dry gas only.
- Check differential pressure stays in range.
- Connect DC 24 V power with correct polarity.
- Wire DeviceNet to the network trunk.
- Tighten fittings to 1/4 inch VCR standard.
- Purge lines before first use.
- Avoid vibration and direct heat sources.
- Confirm leak integrity after installation.
Setup and Maintenance Ease
- DeviceNet lets you set ranges and read flow digitally.
- Multi-gas and multi-range setup cuts spare parts.
- No moving parts inside the flow path.
- Polished 316L body simplifies cleaning.
- Check zero and span yearly.
- Replace filters upstream to protect the sensor.
- Verify calibration with N2 reference gas.
Compatibility Notes
- Works with standard DeviceNet masters and PLCs.
- Fits 1/4 inch VCR, 1.125 inch IGS, and 1.5 inch IGS lines.
- Matches SEC-Z500X series controllers.
- Uses ODVA standard DC 24 V power.
- Pairs with common gas panels and MFC racks.
- Not for corrosive or wet gases without review.
Certifications
- DeviceNet™ protocol compliance.
- ODVA power supply conformity.
- Leak integrity tested with helium.
- 316L stainless steel wetted parts.
- CE marking available on request.
Packing List
- One SEF-Z514MGX mass flow meter.
- One quick start guide.
- One DeviceNet connector kit.
- One calibration certificate.
- Protective caps and packing foam.
FAQ
- Q: What is the fastest response time of this meter?
- A: It responds in 1 second or less over the full flow range.
- Q: Does it measure or control flow?
- A: The SEF version measures flow. The SEC version controls it.
- Q: Which gases can it handle?
- A: N2 is the reference gas. Clean, dry gases work best.
- Q: What network does it use?
- A: It uses DeviceNet™ protocol with DC 24 V power.
- Q: Can I mount it sideways or upside down?
- A: Yes. The mounting orientation is free.
- Q: From experience, how often should I recalibrate?
- A: Most users recalibrate once a year. Harsh gas lines may need six-month checks.
- Q: What is the most common installation mistake?
- A: Skipping upstream filtration. Debris causes drift and short sensor life.
- Q: How do I avoid DeviceNet noise issues?
- A: Keep trunk terminators on both ends. Use shielded cable and a single ground point.
- Q: Why does zero drift appear after warm-up?
- A: The meter needs 15 to 45°C ambient. Let it warm up for 30 minutes before zeroing.
- Q: What flow range should I pick?
- A: Choose a full scale near your typical flow. Best accuracy sits above 25% F.S.
















There are no reviews yet.