Product details
Product Overview
- FCST1500F is an ultra-high-flow mass flow controller from Fujikin.
- It belongs to the FCST T1500 Series.
- Moreover, it controls up to 500 SLM of N2 equivalent flow.
- Some gases reach 1000 SLM with the high-flow option.
- Therefore, it suits large-volume process gas delivery.
- In addition, it fits chamber purge, CVD, and etch bulk gas lines.
- As a result, fabs get steady control at very high flow rates.
- Finally, this product is current and verified as of November 2026.
Technical Specifications
- Brand: Fujikin
- Model: FCST1500F
- Series: FCST T1500 Series Ultra High Flow
- Full-scale flow range: 201 to 500 SLM, N2 equivalent
- High-flow option: up to 1000 SLM for certain gases
- Gas types: customer-specified process gas; non-corrosive high-flow gases such as N2, Ar, and Air
- Accuracy: ±2% FS, guaranteed from 15°C to 35°C
- Repeatability: ±0.2% FS
- Response time: 3 seconds or less
- Linearity: covered within ±2% FS accuracy
- Sensitivity and resolution: tuned for high-flow control across a 2% to 100% range
- Control range: 2% to 100% FS turndown
- Operating temperature: 5°C to 45°C
- Operating pressure: maximum 700 kPaG
- Required differential pressure: 150 to 300 kPa
- Wetted materials: SUS316L stainless steel with PCTFE seats
- Seals: rubber FKM
- Valve type: bellows-sealed diaphragm valve, normally closed only
- Leak integrity: ≤1×10⁻⁷ Pa·m³/s He with rubber seal
- Fittings: 1/2 UJR or F900
- Electrical interface: analog 0-5 VDC with +24 VDC supply; also RS-485, DeviceNet, and EtherCAT
- Power supply: +24 VDC
- Heated option: not included in the standard version
- Environmental resistance: stable output across 5°C to 45°C
- Interference resistance: CE marked for industrial use
Installation Guide
- First, mount the unit in a clean, dry location.
- Then keep ambient temperature between 5°C and 45°C.
- Next, confirm line pressure stays at or below 700 kPaG.
- After that, set differential pressure between 150 and 300 kPa.
- Then use 1/2 UJR or F900 fittings for tight joints.
- Also connect +24 VDC power within rated limits.
- Before gas flows, check leak integrity at all joints.
- Finally, allow flow to settle before zero calibration.
Setup and Maintenance Convenience
- Moreover, the bellows-sealed diaphragm valve limits wear.
- Therefore, service intervals stay long in bulk gas lines.
- In addition, analog and digital options ease controller swaps.
- Also, the 0-5 VDC signal works with most tool controllers.
- Furthermore, the wide turndown covers purge and process steps.
- Meanwhile, SUS316L body material supports clean service.
- As a result, routine checks focus on zero and leak tests.
Compatibility Notes
- Works with analog 0-5 VDC control systems.
- In addition, it supports RS-485, DeviceNet, and EtherCAT.
- Moreover, it fits N2, Ar, Air, and other non-corrosive gases.
- Also, it matches 1/2 UJR and F900 fitting standards.
- Furthermore, it suits large chamber purge and bulk gas supply.
- However, the standard unit is unheated.
- Therefore, review gas temperature needs before selection.
Certifications
- CE marked.
- Also, it is RoHS compliant.
- Moreover, the bellows-sealed valve supports safe high-flow service.
Packing List
- One Fujikin FCST1500F ultra-high-flow MFC.
- Also, one configuration label with model and range data.
- In addition, one quick start guide.
- Moreover, one certificate of compliance.
- Furthermore, fitting and interface options as ordered.
- Finally, cables and accessories only if selected.
FAQ
- What flow can this controller handle?
It covers 201 to 500 SLM of N2 equivalent flow. In addition, certain gases reach 1000 SLM with the high-flow option. - How much differential pressure does it need?
The unit needs 150 to 300 kPa across the valve. Therefore, check your line design before installation. - Which interfaces are available?
Analog 0-5 VDC comes standard. Moreover, RS-485, DeviceNet, and EtherCAT are also offered. - Is the standard unit heated?
No. The standard version is unheated. However, the 5°C to 45°C range covers most bulk gas rooms. - What valve design does it use?
It uses a bellows-sealed diaphragm valve. As a result, it handles high flow with low wear. - What should I check during installation?
First, confirm line pressure and differential pressure. Also check fitting torque and leak integrity before gas flows. - What is a common field experience issue?
Low differential pressure often causes flow shortfall. Therefore, verify the 150 to 300 kPa range at full demand. - Which fittings does it support?
It supports 1/2 UJR and F900 fittings. Moreover, these match common bulk gas panel standards.