Product details
MDX91A-5880-503-4-T00: High-Power Modular Multi-Axis Inverter by SEW-EURODRIVE
The MDX91A-5880-503-4-T00 is a book-style multi-axis inverter from the MOVIDRIVE modular series. It delivers 588.0 A rated output at 4 kHz PWM. It connects directly to a 3-phase AC line. Frame size 9 supports 4-quadrant operation. This unit suits high-power multi-axis cabinets in the MOVI-C platform.
Core Technical Data
- Brand: SEW-EURODRIVE
- Model: MDX91A-5880-503-4-T00
- Series: MOVIDRIVE modular Multi-Axis Inverter (MDX91A)
- Frame size: 9, book-style cabinet design
- Supply voltage: 3 x AC 380 to 500 V nominal, 50 to 60 Hz
- Line frequency tolerance: 50 to 60 Hz plus or minus 5 percent
- Nominal line current: 529.0 A
- Rated output current: 588.0 A at 4 kHz PWM
- Recommended motor power: 315 kW for ASM
- Continuous output at 0 Hz: 541 A (0.9 x I_N)
- Overload capacity: 150 percent of I_N at 2.5 kHz PWM
- PWM frequency: 2.5 and 4 kHz
- Max output frequency: U/f 599 Hz, VFCplus 250 Hz, CFC 500 Hz, ELSM 500 Hz
- Nominal DC link voltage: DC 560 V
- Minimum braking resistance: 2.3 ohm
- Brake chopper: integrated; peak power 200 percent of S_N
- Auxiliary supply: integrated DC 24 V, 80 W, expandable
- Control modes: U/f, VFCplus, CFC, ELSM
Communication and Compatibility
- Built-in system bus: EtherCAT with CiA402 profile
- Fieldbus options: /CFN21A PROFINET IO, /DFE32B EtherNet/IP, /DFI11B PROFIBUS DPV1
- Expansion cards: /CES11A multi-encoder, /CID21A encoder interface, /CIO21A I/O expansion, /CS..A MOVISAFE safety card
- Coating option: /L conformal-coated PCB
- Platform fit: part of the MOVI-C and MOVIDRIVE technology family
Environment and Immunity
- Operating temperature: 0 to +40 C without derating; +40 to +60 C with derating
- Storage temperature: -25 to +70 C, class 1K2, non-condensing
- Transport temperature: -25 to +70 C, class 2K3, non-condensing
- Relative humidity: non-condensing, class 3K3
- Protection rating: IP10 standard; IP20 with plastic terminal covers
- Pollution class: 2 per IEC 60664-1; overvoltage category III
- Installation altitude: up to 1000 m without limit; derating 1 percent per 100 m up to 3800 m
- EMC: basic interference suppression integrated
- Noise immunity: designed for industrial cabinet use with shielded motor cables
Installation Guide
- Mount the unit vertically in a book-style cabinet row.
- Keep the stated clearances for airflow above and below.
- Use M10 copper busbars for line and motor terminals.
- Tighten terminals to the torque in the product manual.
- Connect a braking resistor of at least 2.3 ohm when needed.
- Add external 24 V supply if the 80 W internal budget is short.
- Fit IP20 covers when the cabinet does not shield the terminals.
- Ground the frame with a low-impedance connection.
Setup and Maintenance
- Commission with the MOVIDRIVE engineering tool over EtherCAT.
- Pick U/f for simple pumps and fans.
- Pick CFC or ELSM for fast, precise servo axes.
- Set PWM to 2.5 kHz when full overload headroom is needed.
- Check fan filters and heatsinks on a fixed service interval.
- Read fault codes from the fieldbus and the local display.
- Swap option cards without removing the power section.
Certifications and Scope of Delivery
- Standards: IEC 60664-1, EN 60721-3-1, EN 60721-3-2, EN 60721-3-3
- Overvoltage category: III
- Box contents: one MDX91A-5880-503-4-T00 inverter
- Box contents: printed quick-start guide
- Box contents: terminal covers as ordered
- Not included: braking resistor, option cards, motor cables
FAQ
Q: Can this unit run four motors at once?
A: Yes. It is a multi-axis inverter. Each axis needs its own module in the cabinet.
Q: What output current can I expect at standstill?
A: You get 541 A continuous at 0 Hz. That is 0.9 times the rated current.
Q: How much overload does it give?
A: It gives 150 percent of rated current at 2.5 kHz PWM. Use this for short starts.
Q: Is a braking resistor included?
A: No. Order a BR resistor of at least 2.3 ohm when you need braking energy.
Q: Which feedback card fits a resolver?
A: The /CES11A multi-encoder card covers common encoder types.
Q: From field experience, what causes most trips?
A: Loose busbar joints and blocked airflow cause most overtemperature trips. Check both at each service.
Q: Can I install it above 1000 m?
A: Yes. Derate rated current by 1 percent per 100 m up to 3800 m.
















There are no reviews yet.