Product details
Product Overview
- Model MDX91A-0125-5E3-4-T00 is a book-style multi-axis inverter from SEW-EURODRIVE.
- It belongs to the MOVIDRIVE modular Multi-Axis Inverter (MDX91A) series.
- Rated output is 12.5 A at 4 kHz PWM. It connects directly to 3~AC line supply.
- The drive supports 4-quadrant operation. It suits coordinated multi-axis machine concepts.
- Frame size is 3. The unit mounts in a control cabinet.
- An integrated DC 24 V auxiliary supply (80 W) is included. You can add an external supply if needed.
- Control modes cover U/f, VFCplus, CFC and ELSM. This gives flexibility across standard and synchronous motor tasks.
- A brake chopper is built in. An optional braking resistor BR.. is available.
- Line and motor terminals use plug connectors. Wire range is 0.25-4 mm², or 0.25-2.5 mm² for twin conductors.
- The integrated EMC filter meets limit value class C2 acc. to EN 61800-3.
- The product is part of the MOVI-C platform. The official product manual is active.
Technical Data
- Brand: SEW-EURODRIVE
- Model: MDX91A-0125-5E3-4-T00
- Series: MOVIDRIVE modular Multi-Axis Inverter (MDX91A)
- Module type: Multi-axis application inverter, book-style, frame size 3
- Supply voltage: 3 x AC 380-500 V nominal, 50-60 Hz
- Line frequency tolerance: 50-60 Hz ±10%
- Nominal line current: 11.3 A
- Rated output current: 12.5 A at f_PWM = 4 kHz
- Recommended motor power (ASM): 5.5 kW
- Apparent output power S_N: 11.6 kVA
- Overload capacity: 200% of I_N for 3 s at 4 kHz; continuous 100% x I_N at 4 kHz
- Continuous output current at 0 Hz: I_N x 0.9
- PWM frequency: 4, 8, 16 kHz, adjustable
- Max output frequency: U/f 599 Hz; VFCplus 250 Hz; CFC 500 Hz; ELSM 500 Hz
- Nominal DC link voltage: DC 560 V
- Minimum braking resistance R_BRmin: 215 Ω
- Brake chopper continuous power: 11.6 kW; peak power 200% x S_N
- Power section nominal power loss: 83 W
- Control modes: U/f, VFCplus, CFC, ELSM
- Operating temperature: 0 to +40 °C without derating; +40 to +60 °C with derating
- Storage temperature: -25 to +70 °C, class 1K2, non-condensing
- Transport temperature: -25 to +70 °C, class 2K3, non-condensing
- Relative humidity: non-condensing, class 3K3
- Protection rating: IP20 (EN 60529)
- Pollution class: 2 (IEC 60664-1); overvoltage category III
- Installation altitude: up to 1000 m without restriction; 1000-3800 m with 1% I_N derating per 100 m
- Dimensions (H×W×D): 494×105×260 mm, height with shield plates
- Weight: published in dimension drawings per size
Communication and Compatibility
- Built-in system bus: EtherCAT / CiA402 (MOVIDRIVE technology variant).
- Fieldbus control runs over the system bus. You can add fieldbus cards for other networks.
- Fieldbus options: /CFN21A PROFINET IO, /DFE32B EtherNet/IP, /DFI11B PROFIBUS DPV1.
- Expansion cards: /CES11A multi-encoder, /CID21A encoder interface, /CIO21A I/O expansion.
- Safety and coating options: /CS..A MOVISAFE safety card, /L conformal-coated PCB.
- The drive fits MOVI-C platform projects. It works with standard asynchronous and synchronous motors.
- Check card slots and firmware before you plan a mixed network. This avoids integration surprises.
Installation Guide
- Mount the book-style unit vertically in a control cabinet. Keep the frame size 3 clearance values from the manual.
- Use the plug connectors for line and motor cables. Observe the wire range: 0.25-4 mm², or 0.25-2.5 mm² for twin conductors.
- Connect the DC 24 V auxiliary supply if you need control power without line voltage.
- Install a braking resistor BR.. when braking energy must be dissipated. Respect R_BRmin = 215 Ω.
- Keep the IP20 rating in mind. The cabinet must provide the final environmental protection.
- Follow class C2 EMC wiring practice. Use shielded motor cables and solid PE bonds.
- For altitudes above 1000 m, apply the 1% I_N derating per 100 m rule.
- Above +40 °C, apply the derating curve from the manual. Do not exceed +60 °C.
Commissioning and Maintenance
- Start with the U/f mode for simple tests. Move to VFCplus, CFC or ELSM for dynamic or synchronous duties.
- Set PWM frequency to 4, 8 or 16 kHz. Higher settings reduce motor noise but raise losses.
- Use the EtherCAT / CiA402 interface for fast commissioning with a PLC.
- Check the DC link voltage and brake chopper behavior during first runs.
- Keep the heat sink clean. Dust and clogged fins raise the 83 W power loss effect.
- Store spare option cards in ESD-safe packaging. This protects the encoder and I/O interfaces.
- Log firmware versions and card slots. This speeds up service and spare-part ordering.
Environmental Resistance and Noise Immunity
- Operating range is 0 to +60 °C with derating above +40 °C.
- Storage and transport cover -25 to +70 °C under classes 1K2 and 2K3.
- Humidity must stay non-condensing under class 3K3.
- The integrated EMC filter (class C2) limits conducted emissions. It supports stable operation in industrial networks.
- Overvoltage category III and pollution class 2 match typical cabinet environments.
- Use shielded cables and proper grounding to keep noise low. This matters most near encoders and PLC signals.
Certifications and Standards
- EN 61800-3 class C2 EMC filter, integrated.
- EN 60529 protection rating IP20.
- IEC 60664-1 pollution class 2, overvoltage category III.
- EN 60721-3-1 class 1K2 for storage; EN 60721-3-2 class 2K3 for transport; EN 60721-3-3 class 3K3 for operation.
- Always confirm the current certificate set in the official SEW-EURODRIVE manual for your build.
Packing List
- 1 x MDX91A-0125-5E3-4-T00 inverter, frame size 3.
- Plug connectors for line and motor terminals.
- Shield plates for the stated height dimension.
- Printed quick-start or safety notes, as supplied by SEW-EURODRIVE.
- Option cards and braking resistors ship only when ordered. They are not part of the base unit.
FAQ
- Can I run this drive on a 400 V line?
Yes. The nominal range is 380-500 V, 50-60 Hz. Check your line tolerance before you set parameters. - What motor size fits best?
The recommended ASM power is 5.5 kW. The 12.5 A output also suits many synchronous motors in ELSM mode. - Does it include a fieldbus card?
No. EtherCAT/CiA402 is built in. PROFINET, EtherNet/IP and PROFIBUS need the matching option card. - How much overload can it take?
It delivers 200% of I_N for 3 s at 4 kHz PWM. Continuous current stays at 100% x I_N. - Can I mount it above 1000 m?
Yes, with 1% I_N derating per 100 m up to 3800 m. Plan cooling carefully at high altitude. - Is a braking resistor required?
Not always. The brake chopper is built in. Add a BR.. resistor if your load regenerates often. Respect the 215 Ω minimum. - What surprised installers most?
The plug connectors save time, but wire range limits matter. Twin conductors stop at 2.5 mm². Prepare ferrules before you start. - How do I avoid nuisance trips during ramp changes?
Match PWM frequency and ramp times to the load. Start in VFCplus, then tune CFC or ELSM after the mechanics run smoothly. - What should I check before ordering options?
Confirm the card slot count and firmware level. Also check whether the /L coated PCB is needed for your environment. - Where is the weight listed?
SEW-EURODRIVE publishes weight in the dimension drawings per size. Use the frame size 3 drawing for logistics planning.