Product details
MDX91A-0160-5E3-4-T00 | SEW-EURODRIVE MOVIDRIVE Multi-Axis Inverter, 16 A
This MDX91A-0160-5E3-4-T00 is a book-style inverter from SEW-EURODRIVE. It is part of the MOVIDRIVE modular Multi-Axis Inverter (MDX91A) series. The unit gives 16.0 A rated output at 4 kHz PWM. It runs on a direct 3~AC 380-500 V line. Frame size 3 supports 4-quadrant operation. An internal DC 24 V supply (80 W) feeds the control side. A brake chopper is built in. This drive fits cabinet-based multi-axis systems with higher power needs.
Key Specs at a Glance
- Brand: SEW-EURODRIVE
- Model: MDX91A-0160-5E3-4-T00
- Series: MOVIDRIVE modular Multi-Axis Inverter (MDX91A)
- Module type: Multi-axis application inverter, frame size 3
- Supply voltage: 3 x AC 380-500 V nominal, 50-60 Hz
- Nominal line current: 14.4 A
- Rated output current: 16.0 A at 4 kHz PWM
- Recommended motor power (ASM): 7.5 kW
- Apparent output power S_N: 14.9 kVA
- Overload: 200% of I_N for 3 s at 4 kHz PWM; 100% x I_N continuous
- Output current at 0 Hz: I_N x 0.9
- PWM frequency: 4, 8, 16 kHz adjustable
- Max output frequency: U/f 599 Hz; VFCplus 250 Hz; CFC 500 Hz; ELSM 500 Hz
- DC link voltage: DC 560 V nominal
- Min braking resistance R_BRmin: 215 Ω
- Brake chopper: 14.9 kW continuous; peak 200% x S_N
- Power loss: 112 W in the power section
- Dimensions (H×W×D): 494 x 105 x 260 mm with shield plates
Function Tree and Option Suffixes
The model code follows a tree. Each level adds a function. Read it from top to bottom.
- MDX91A
- -0160
- Rated output current: 16.0 A at 4 kHz PWM
- Frame size 3 body
- -5E3
- Supply class: 3~AC 380-500 V, 50-60 Hz
- Integrated EMC filter, class C2 acc. to EN 61800-3
- -4
- Technology variant: EtherCAT / CiA402 system bus
- Fieldbus control ready
- -T00
- Standard terminal and option layout
- Plug connectors: 0.25-4 mm²; twin conductor 0.25-2.5 mm²
- -0160
Control and Interference Immunity
- Control modes: U/f, VFCplus, CFC, ELSM
- CFC: field-oriented current control for closed-loop duty
- ELSM: extended synchronous motor control
- EMC: integrated filter, class C2 per EN 61800-3
- Pollution class: 2 (IEC 60664-1); overvoltage category III
- Noise control: set PWM to 8 or 16 kHz to cut motor noise
Environment and Durability
- Operating temperature: 0 to +40 °C without derating; +40 to +60 °C with derating
- Storage temperature: -25 to +70 °C, class 1K2, non-condensing
- Transport temperature: -25 to +70 °C, class 2K3, non-condensing
- Humidity: non-condensing, class 3K3
- Protection: IP20 (EN 60529)
- Altitude: up to 1000 m free; 1000-3800 m with 1% I_N derating per 100 m
- Harsh site option: /L conformal-coated PCB
Communication and Fit
- Built-in bus: EtherCAT / CiA402 on the system bus
- Fieldbus cards: /CFN21A PROFINET IO, /DFE32B EtherNet/IP, /DFI11B PROFIBUS DPV1
- Encoder cards: /CES11A multi-encoder, /CID21A encoder interface
- I/O card: /CIO21A expansion
- Safety card: /CS..A MOVISAFE
- Platform: MOVI-C (MOVIDRIVE system / MOVIDRIVE technology)
Mounting Steps
- Place the frame size 3 unit upright in the cabinet.
- Keep the air gaps from the manual.
- Wire the 3~AC 380-500 V line to the plug connector.
- Wire the motor with 0.25-4 mm² conductors.
- Add an external DC 24 V supply if 80 W is not enough.
- Fit a BR.. resistor of at least 215 Ω for braking energy.
- Keep power and signal cables apart.
- Derate above 1000 m altitude.
Setup and Service
- Pick the control mode for your motor type.
- Use CFC or ELSM for closed-loop axes.
- Set PWM to 4, 8 or 16 kHz.
- Check the DC 560 V link before enable.
- Plug terminals make a drive swap fast.
- Read faults over EtherCAT / CiA402.
- Clean the heat sink at set intervals.
Best Fit: Equipment and Applications
- Packaging lines: multi-axis motion with 7.5 kW motors
- Palletizers and handling cells: fast stops with brake chopper support
- Material transport: conveyors and shuttles on one DC bus
- Machine tools and woodworking: CFC speed loops
- Food and beverage lines: clean cabinet build with IP20
- Automotive assembly: EtherCAT plant control
- Printing and paper: tight speed sync across axes
- Logistics hubs: long running hours, low service needs
Frequently Asked Questions
Q: How many axes can share one DC bus?
A: The design allows several MDX91A units on a common DC link. Plan the bus with the total motor load and the 14.9 kVA apparent power per unit.
Q: What is the smallest brake resistor I may use?
A: 215 Ω is the published minimum for this model. A smaller value draws too much current from the chopper.
Q: Can the drive run a permanent magnet motor?
A: Yes, ELSM mode covers extended synchronous motors. Check the motor data against the 16.0 A output.
Q: How do I know the frame size from the code?
A: The -0160 block sets the current and frame size 3. The 494 x 105 x 260 mm body matches that block.
Q: What cable size fits the power terminals?
A: Use 0.25-4 mm² wire. Twin conductors run 0.25-2.5 mm².
Q: From experience, why does a high-power axis trip at start?
A: A too-high PWM setting with a long motor cable is a common cause. Drop to 4 kHz and check the cable shield first.
Q: From experience, what helps when cabinet heat is tight?
A: Mount the book-style units side by side with the manual gap. Add fan cooling. Check the 112 W loss per unit in your heat budget.
Q: From experience, how do I avoid brake resistor faults?
A: Size the resistor for the real stop cycle. Keep the 215 Ω limit. Check the resistor wiring before first enable.
















There are no reviews yet.