Product details
Meet the MDX91A-0070-5E3-4-T00
This drive comes from SEW-EURODRIVE. It sits in the MOVIDRIVE modular Multi-Axis Inverter (MDX91A) family. The unit gives 7.0 A rated output at 4 kHz PWM. It runs on a direct 3-phase AC line. Also, it saves cabinet space with its book-style frame. As a result, it fits tight multi-axis builds.
- Best fit
- Frame size 2 with 4-quadrant operation.
- Drives async and sync motors.
- Suits 3 kW standard motors.
- Smart extras
- DC 24 V helper supply, 80 W, can grow outside.
- Brake chopper is built in.
- Add resistor BR.. when needed.
Key Data at a Glance
- Name plate
- Brand: SEW-EURODRIVE
- Model: MDX91A-0070-5E3-4-T00
- Series: MOVIDRIVE MDX91A
- Type: multi-axis application inverter, frame size 2
- Power side
- Line: 3 x AC 380-500 V, 50-60 Hz.
- Line tolerance: ±10%.
- Line current: 6.3 A.
- Output current: 7.0 A at 4 kHz PWM.
- Motor power ASM: 3 kW.
- Output power S_N: 6.5 kVA.
- DC link: DC 560 V.
- Zero Hz current: I_N x 0.9.
- Load and speed
- Overload: 200% of I_N for 3 s.
- Continuous load: 100% x I_N at 4 kHz.
- PWM steps: 4, 8, 16 kHz.
- Top frequency: U/f 599 Hz, VFCplus 250 Hz, CFC 500 Hz, ELSM 500 Hz.
- Brake side
- R_BRmin: 479 Ω.
- Chopper continuous power: 6.5 kW.
- Chopper peak power: 200% x S_N.
- Power loss: 45 W.
- Site limits
- Heat: 0 to +40 °C, full load.
- Derate range: +40 to +60 °C.
- Store and move: -25 to +70 °C, class 1K2 / 2K3.
- Air: non-condensing, class 3K3.
- Guard: IP20 acc. to EN 60529.
- Pollution class 2; overvoltage cat. III.
- Height: 1000 m free; then 1% I_N drop per 100 m up to 3800 m.
- Size
- H×W×D: 479×105×215 mm, with shield plates.
- Weight: shown in SEW size drawings.
Ports and Option Cards
- On board
- System bus: EtherCAT / CiA402.
- Fieldbus control via the MOVIDRIVE technology variant.
- Fieldbus add-ons
- /CFN21A gives PROFINET IO.
- /DFE32B gives EtherNet/IP.
- /DFI11B gives PROFIBUS DPV1.
- More cards
- /CES11A multi-encoder.
- /CID21A encoder port.
- /CIO21A I/O growth.
- /CS..A MOVISAFE safety.
- /L coated PCB for harsh air.
Control Modes
- U/f for easy jobs.
- VFCplus for voltage-frequency control.
- CFC for field-oriented current control.
- ELSM for extended synchronous motor control.
Where It Shines
- Machines
- Packaging lines with many axes.
- Palletizers and handling gantries.
- Printing and paper converting.
- Food and beverage fillers.
- Conveyor groups with shared DC bus.
- Why these fit
- Book frame packs axes side by side.
- 4-quadrant mode saves energy on stops.
- EtherCAT keeps cycle times short.
- Shared DC link cuts wiring.
Mounting and Wiring
- Fit in a control cabinet, book style.
- Keep IP20 clearance for airflow.
- Plan for 45 W loss.
- Use plug connectors for line and motor.
- Terminal range: 0.25-4 mm²; twin 0.25-2.5 mm².
- Add BR.. resistor if stops are heavy.
- Keep R_BRmin at 479 Ω or above.
Setup and Service
- Pick the control mode for your motor.
- Set PWM to 4, 8, or 16 kHz.
- Bind the drive to EtherCAT / CiA402.
- Add fieldbus cards for plant nets.
- Use plug connectors for fast swaps.
- CiA402 diagnostics show clear faults.
Approvals and EMC
- EMC filter is inside.
- Class C2 acc. to EN 61800-3.
- IP20 acc. to EN 60529.
- Pollution class 2 acc. to IEC 60664-1.
- Overvoltage cat. III.
- Climate classes 1K2, 2K3, 3K3 acc. to EN 60721.
- MOVISAFE card adds safety tasks.
In the Box
- MDX91A-0070-5E3-4-T00 inverter, 1 pc.
- Line and motor plugs.
- Shield plates.
- Short install notes.
- Resistor BR.. and cards ship apart.
FAQ
- Which motors pair well with this size?
- Plan for a 3 kW async motor. Sync motors also work with ELSM. Check nameplate current first.
- Why is R_BRmin 479 Ω here?
- Frame size 2 needs a higher value than size 1. A lower ohm resistor can trip the chopper. From field practice, match the resistor to the size, not the old unit.
- Can several units share one DC bus?
- Yes, the multi-axis layout allows a common DC link. This cuts line wiring and reuses brake energy. In practice, size the bus for the worst stop.
- How do I cut noise on encoder lines?
- Keep motor cables short and shielded. Ground the shield plates well. Also route encoder wires away from motor leads. This avoids feedback faults.
- What should I check at high altitude?
- Above 1000 m, drop I_N by 1% per 100 m. Also watch cabinet air flow. From experience, add cooling before you reach the limit, not after.
















There are no reviews yet.