Product details
Product Overview
MDX91A-0055-5E3-4-T00 is a book-style multi-axis inverter from SEW-EURODRIVE. It belongs to the MOVIDRIVE modular Multi-Axis Inverter (MDX91A) series. Moreover, this unit delivers 5.5 A rated output at 4 kHz PWM. It also connects directly to a 3-phase AC line. As a result, it suits compact control-cabinet builds with high power density.
- Core role
- It drives asynchronous and synchronous motors.
- In addition, it supports 4-quadrant operation with regenerative energy.
- Therefore, it fits multi-axis machine and system layouts.
- Control modes
- U/f control works well for simple tasks.
- Meanwhile, VFCplus handles voltage-frequency control.
- Furthermore, CFC field-oriented current control gives high dynamics.
- Finally, ELSM covers extended synchronous motor control.
- Built-in functions
- It includes a DC 24 V auxiliary power supply, 80 W, expandable externally.
- It also has an integrated brake chopper.
- Moreover, an optional braking resistor BR.. is available.
Technical Specifications
- Brand and model
- Brand: SEW-EURODRIVE
- Model: MDX91A-0055-5E3-4-T00
- Series: MOVIDRIVE modular Multi-Axis Inverter (MDX91A)
- Module type: multi-axis application inverter, frame size 1
- Electrical data
- Supply voltage is 3 x AC 380-500 V nominal, 50-60 Hz.
- In addition, line frequency tolerance stays at 50-60 Hz ±10%.
- Nominal line current is 4.95 A.
- However, rated output current is 5.5 A at f_PWM = 4 kHz.
- Recommended motor power ASM is 2.2 kW.
- Likewise, apparent output power S_N is 5.0 kVA.
- Nominal DC link voltage is DC 560 V.
- Moreover, continuous output current at f = 0 Hz is I_N x 0.9.
- Overload and switching
- Overload capacity is 200% of I_N for 3 s at 4 kHz PWM.
- Meanwhile, continuous load stays at 100% x I_N at 4 kHz PWM.
- PWM frequency is adjustable: 4, 8, 16 kHz.
- Also, max output frequency is U/f 599 Hz, VFCplus 250 Hz, CFC 500 Hz, ELSM 500 Hz.
- Braking and losses
- Minimum braking resistance R_BRmin is 95 Ω.
- Brake chopper continuous power is 5.0 kW.
- In addition, brake chopper peak power is 200% x S_N.
- Power section nominal power loss is 34 W.
- Measurement and control performance
- Current measurement range goes up to 5.5 A rated output.
- Moreover, frequency response reaches up to 599 Hz output, mode dependent.
- CFC and ELSM closed-loop control set sensitivity and linearity.
- Furthermore, field-oriented control provides fine current and speed resolution.
- Temperature range is 0 to +40 °C without derating.
- Then, derating range is +40 to +60 °C with derating.
- Also, environment tolerance is non-condensing humidity, pollution class 2.
- Interference immunity comes from an integrated EMC filter, class C2 acc. to EN 61800-3.
- Environmental and physical data
- Operating temperature is 0 to +40 °C without derating.
- Storage temperature is -25 to +70 °C, class 1K2, non-condensing.
- Similarly, transport temperature is -25 to +70 °C, class 2K3, non-condensing.
- Relative humidity stays non-condensing, class 3K3.
- Protection rating is IP20 acc. to EN 60529.
- Also, pollution class is 2 acc. to IEC 60664-1; overvoltage category III.
- Installation altitude is up to 1000 m without restriction.
- At high altitude, 1000-3800 m, I_N drops 1% per 100 m.
- Dimensions (H×W×D) are 479×95×215 mm, height with shield plates.
- Finally, weight is 4.1 kg.
Communication and Compatibility
- Built-in ports
- The system bus is EtherCAT / CiA402.
- Meanwhile, fieldbus control runs through the MOVIDRIVE technology variant.
- Fieldbus option cards
- /CFN21A adds PROFINET IO.
- /DFE32B adds EtherNet/IP.
- In addition, /DFI11B adds PROFIBUS DPV1.
- Expansion option cards
- /CES11A is a multi-encoder card.
- /CID21A is an encoder interface.
- Moreover, /CIO21A expands I/O.
- /CS..A is a MOVISAFE safety card.
- Finally, /L is a conformal-coated PCB.
- Compatibility notes
- It works inside the MOVI-C platform.
- It also fits MOVIDRIVE system and MOVIDRIVE technology setups.
- Furthermore, line and motor terminals use plug connectors.
- Terminal range is 0.25-4 mm²; twin conductor 0.25-2.5 mm².
Installation Guide
- Mounting
- First, use book-style mounting in a control cabinet.
- Keep the IP20 frame size 1 clearance.
- Also, respect the 479×95×215 mm footprint.
- Therefore, allow airflow for 34 W power loss.
- Wiring
- Connect the 3 x AC 380-500 V line supply.
- Then use plug connectors for line and motor.
- Keep terminal sizes within 0.25-4 mm².
- Moreover, add a braking resistor BR.. if needed.
- Also observe R_BRmin of 95 Ω.
- Environment
- Install at 0 to +40 °C for full rating.
- Then derate above +40 °C up to +60 °C.
- Keep humidity non-condensing.
- Finally, follow altitude derating above 1000 m.
Commissioning and Maintenance
- Commissioning
- First, select the control mode for the motor type.
- Then set PWM frequency: 4, 8, or 16 kHz.
- Next, configure EtherCAT / CiA402 system bus.
- Finally, add fieldbus cards for plant networks.
- Maintenance ease
- Plug connectors speed up unit swaps.
- Meanwhile, the book-style frame saves cabinet space.
- Moreover, optional /L coating adds protection in harsh air.
- Therefore, CiA402 diagnostics give clear fault paths.
Certifications and EMC
- An EMC filter is built in.
- It meets limit value class C2 acc. to EN 61800-3.
- Also, protection rating is IP20 acc. to EN 60529.
- Pollution class is 2 acc. to IEC 60664-1.
- Overvoltage category is III.
- In addition, climate classes are 1K2, 2K3, and 3K3 acc. to EN 60721.
- Moreover, the MOVISAFE safety card option adds safety functions.
Package List
- MDX91A-0055-5E3-4-T00 inverter unit, 1 pc.
- Line and motor plug connectors.
- Shield plates for the 479 mm height.
- Also, quick installation notes.
- Braking resistor BR.. and option cards ship separately.
FAQ
- What motor power does this unit support?
- It recommends a 2.2 kW asynchronous motor. In addition, the 5.5 A output covers many standard motor sizes.
- Can I run it without a braking resistor?
- Yes, the brake chopper is built in. However, add a BR.. resistor for heavy regenerative stops. Keep R_BRmin at 95 Ω or higher.
- How much overload can it take?
- It handles 200% of I_N for 3 s at 4 kHz PWM. Meanwhile, continuous load stays at 100% x I_N.
- Which fieldbus can I add?
- Choose /CFN21A for PROFINET IO, /DFE32B for EtherNet/IP, or /DFI11B for PROFIBUS DPV1.
- What happens at high altitude?
- Up to 1000 m it runs unrestricted. From 1000 to 3800 m, however, derate I_N by 1% per 100 m.
- Is it hard to replace in the cabinet?
- No. Plug connectors and the book-style frame make swaps fast. From experience, label each cable before removal. As a result, downtime drops on multi-axis lines.
- Does it need extra EMC work?
- An EMC filter is built in and meets class C2. In practice, keep motor cables short and shielded. Also ground the shield plates well. Therefore, this avoids noise on encoder lines.
- Which control mode should I pick?
- Use U/f for simple pumps and fans. Pick CFC or ELSM when you need fast torque response. Meanwhile, VFCplus suits general speed control.















There are no reviews yet.