Product details
Product Overview
- MDX91A-0032-5E3-4-T00 is a SEW-EURODRIVE multi-axis inverter.
- It belongs to the MOVIDRIVE modular Multi-Axis Inverter (MDX91A) series.
- It delivers 3.2 A rated output at 4 kHz PWM.
- It connects directly to a 3~AC line.
- The book-style cabinet unit saves space in multi-axis systems.
- It supports 4-quadrant operation for motoring and regenerating.
- A DC 24 V auxiliary supply with 80 W is built in.
- You can add an external supply for extra backup power.
- An integrated brake chopper handles braking energy.
- An optional BR.. braking resistor completes the brake path.
- The unit uses plug connectors for line and motor cables.
- This design speeds up wiring and servicing.
- The drive targets industrial automation users who need compact multi-axis control.
- It fits conveying, packaging, handling, and similar machine tasks.
- SEW-EURODRIVE keeps this model in its current product line.
Technical Specifications
- Brand: SEW-EURODRIVE
- Model: MDX91A-0032-5E3-4-T00
- Series: MOVIDRIVE modular Multi-Axis Inverter (MDX91A)
- Module type: multi-axis application inverter
- Frame size: 1
- Supply voltage: 3 x AC 380-500 V nominal
- Line frequency: 50-60 Hz, tolerance ±10%
- Nominal line current: 2.88 A
- Rated output current: 3.2 A at 4 kHz PWM
- Recommended motor power (ASM): 1.1 kW
- Apparent output power S_N: 2.9 kVA
- Overload capacity: 200% of I_N for 3 s at 4 kHz PWM
- Continuous overload: 100% x I_N at 4 kHz PWM
- Continuous output current at 0 Hz: I_N x 0.9
- PWM frequency: 4, 8, 16 kHz, adjustable
- Max output frequency: U/f 599 Hz; VFCplus 250 Hz; CFC 500 Hz; ELSM 500 Hz
- Nominal DC link voltage: DC 560 V
- Minimum braking resistance R_BRmin: 95 Ω
- Brake chopper continuous power: 2.9 kW; peak 200% x S_N
- Power section nominal loss: 20 W
- Control modes: U/f, VFCplus, CFC, ELSM
- Line/motor terminal range: 0.25-4 mm²; twin conductor 0.25-2.5 mm²
- Dimensions (H×W×D): 479×95×215 mm, height with shield plates
- Weight: 4.1 kg
- Temperature range, operating: 0 to +40 °C without derating; +40 to +60 °C with derating
- Temperature range, storage: -25 to +70 °C, EN 60721-3-1 class 1K2, non-condensing
- Temperature range, transport: -25 to +70 °C, EN 60721-3-2 class 2K3, non-condensing
- Relative humidity: non-condensing, no moisture condensation, EN 60721-3-3 class 3K3
- Protection rating: IP20 per EN 60529
- Pollution class: 2 per IEC 60664-1; overvoltage category III
- Installation altitude: up to 1000 m without restriction; 1000-3800 m with I_N derating of 1% per 100 m
- EMC variant: integrated EMC filter, limit value class C2 per EN 61800-3
- Interference resistance: the integrated EMC filter and C2 class limit conducted noise in industrial settings.
- Resolution and accuracy: the drive controls speed and torque through its current controller. Exact figures depend on the motor encoder and option card.
Communication and Compatibility
- Built-in system bus: EtherCAT / CiA402 for fieldbus control.
- This variant ships as a MOVIDRIVE technology unit.
- Fieldbus option cards: /CFN21A PROFINET IO, /DFE32B EtherNet/IP, /DFI11B PROFIBUS DPV1.
- Communication expansion cards: /CES11A multi-encoder, /CID21A encoder interface, /CIO21A I/O expansion.
- Safety card: /CS..A MOVISAFE.
- Coating option: /L conformal-coated PCB for harsh air.
- The drive fits the MOVI-C platform, under the MOVIDRIVE system and MOVIDRIVE technology families.
- It works with asynchronous motors and synchronous motors, including ELSM.
- Encoder feedback comes from the option cards above.
- Check card slots and firmware before you order options.
Installation Guide
- Mount the unit upright in a control cabinet with IP20 protection.
- Keep the stated clearances for airflow above and below the unit.
- Connect the 3~AC 380-500 V line through the plug connector.
- Use cable sizes within 0.25-4 mm².
- Wire the motor to the motor plug connector.
- Add a BR.. braking resistor if you need high braking duty.
- Keep the resistor above 95 Ω minimum.
- Feed the DC 24 V auxiliary input if you want external backup.
- Use shielded cables for the EtherCAT system bus.
- Follow local wiring rules and the official manual.
- Above 1000 m altitude, apply the 1% per 100 m current derating.
Commissioning and Maintenance
- Start with the U/f mode for simple motor tests.
- Switch to VFCplus, CFC, or ELSM for higher demand.
- Set the PWM frequency to 4, 8, or 16 kHz as needed.
- Use the EtherCAT / CiA402 bus to load parameters.
- The plug connectors speed up module swaps.
- Check fan paths and dust build-up at each service interval.
- Keep spare option cards on hand for fast repair.
- The /L coated board option suits humid or dirty air.
Certifications and Standards
- EMC: EN 61800-3, limit value class C2 with the integrated filter.
- Protection: EN 60529, rating IP20.
- Pollution degree: IEC 60664-1, class 2.
- Overvoltage category: III.
- Climate classes: EN 60721-3-1 class 1K2, EN 60721-3-2 class 2K3, EN 60721-3-3 class 3K3.
- Confirm the final CE and UL status on the official SEW-EURODRIVE manual and nameplate.
Package Contents
- 1 x MDX91A-0032-5E3-4-T00 inverter.
- 1 x plug connector set for line and motor.
- 1 x printed quick guide.
- Option cards and braking resistors ship only when ordered.
- Check the box for damage before you sign.
FAQ
- Can this unit run a 1.1 kW motor?
- Yes. SEW-EURODRIVE recommends 1.1 kW for an ASM motor at 4 kHz PWM.
- Does it include a braking resistor?
- No. The brake chopper is built in. The BR.. resistor is an option.
- Which bus does it use out of the box?
- It uses EtherCAT / CiA402 on the system bus.
- Can I add PROFINET?
- Yes. Add the /CFN21A card for PROFINET IO.
- What happens above 40 °C?
- The drive runs to +60 °C with output derating.
- Can I mount it at 2000 m altitude?
- Yes, with an I_N derating of about 10% at 2000 m.
- Is the cabinet filter enough for C2?
- Yes. The integrated EMC filter meets class C2 per EN 61800-3.
- How do I avoid nuisance trips on a shared bus?
- Use shielded bus cable and separate it from motor cables. Field experience shows this cuts noise faults.
- What is a common startup mistake?
- Many users forget the 24 V auxiliary feed. Then the control board stays dark after a line stop.
- How do I cut downtime on a multi-axis line?
- Keep one spare unit and one spare option card. The plug connectors make the swap fast.















There are no reviews yet.