Product details
Product Overview
- Model MDX91A-0025-5E3-4-T00 is a SEW-EURODRIVE multi-axis inverter.
- It belongs to the MOVIDRIVE modular Multi-Axis Inverter (MDX91A) series.
- This is a book-style control-cabinet inverter for compact multi-axis systems.
- It delivers 2.5 A rated output at 4 kHz PWM.
- It connects directly to 3~AC line without extra transformers.
- It supports 4-quadrant operation for motoring and regenerating.
- An integrated DC 24 V auxiliary supply (80 W) powers control electronics.
- An integrated brake chopper handles braking energy; resistor BR.. is optional.
- Frame size 1 fits narrow cabinet spaces.
- Plug connectors simplify line and motor wiring.
Technical Data
- Brand: SEW-EURODRIVE
- Model: MDX91A-0025-5E3-4-T00
- Series: MOVIDRIVE modular Multi-Axis Inverter (MDX91A)
- Module Type: Multi-axis application inverter, book-style, frame size 1
- Supply Voltage: 3 x AC 380–500 V nominal, 50–60 Hz
- Line Frequency Tolerance: 50–60 Hz ±10%
- Nominal Line Current: 2.25 A
- Rated Output Current: 2.5 A at f_PWM = 4 kHz
- Recommended Motor Power (ASM): 0.75 kW
- Apparent Output Power S_N: 2.3 kVA
- Overload Capacity: 200% of I_N for 3 s at 4 kHz PWM
- Continuous Output Current at 0 Hz: I_N x 0.9
- PWM Frequency: 4, 8, 16 kHz adjustable
- Max Output Frequency:
- U/f: 599 Hz
- VFCplus: 250 Hz
- CFC: 500 Hz
- ELSM: 500 Hz
- Nominal DC Link Voltage: DC 560 V
- Minimum Braking Resistance R_BRmin: 95 Ω
- Brake Chopper Continuous Power: 2.3 kW; peak 200% x S_N
- Power Section Nominal Power Loss: 20 W
- Control Modes: U/f, VFCplus, CFC, ELSM
- Temperature Range (Operation): 0 to +40 °C without derating; +40 to +60 °C with derating
- Storage Temperature: -25 to +70 °C, non-condensing
- Transport Temperature: -25 to +70 °C, non-condensing
- Relative Humidity: Non-condensing, no moisture condensation
- Protection Rating: IP20
- Pollution Class: 2 (IEC 60664-1); overvoltage category III
- Installation Altitude: Up to 1000 m without restriction; 1000–3800 m with 1% derating per 100 m
- Dimensions (H×W×D): 479×95×215 mm (height with shield plates)
- Weight: 4.1 kg
- EMC Variant: Integrated EMC filter, limit value class C2 acc. to EN 61800-3
- Interference Immunity: Designed for industrial EMC environments per EN 61800-3 C2 filter
Communication and Compatibility
- Built-in Ports: System bus EtherCAT / CiA402 (MOVIDRIVE technology variant)
- Fieldbus Control: EtherCAT/CiA402 on system bus
- Fieldbus Options via Cards:
- /CFN21A PROFINET IO
- /DFE32B EtherNet/IP
- /DFI11B PROFIBUS DPV1
- Communication Expansion Options:
- /CES11A multi-encoder
- /CID21A encoder interface
- /CIO21A I/O expansion
- /CS..A MOVISAFE safety card
- /L conformal-coated PCB
- Compatibility Note: Works with MOVIDRIVE system / MOVIDRIVE technology and the MOVI-C platform.
- Line/Motor Terminals: Plug connector for 0.25–4 mm²; twin conductor 0.25–2.5 mm².
- Auxiliary Supply: Integrated DC 24 V, 80 W; can be supplemented externally.
Installation Guide
- Mount the inverter vertically in a control cabinet.
- Keep IP20 protection in mind; avoid dust and moisture.
- Respect clearance for heat loss of 20 W.
- Use the book-style frame to save cabinet width.
- Connect line and motor via plug connectors.
- Use wire sizes 0.25–4 mm² for single conductors.
- Use twin conductors of 0.25–2.5 mm² where needed.
- Connect the DC 24 V auxiliary supply for control power.
- Add an external DC 24 V supply if more power is needed.
- Install a braking resistor BR.. if high braking energy occurs.
- Keep R_BRmin at 95 Ω or higher.
- Check altitude; derate 1% per 100 m above 1000 m.
- Follow EN 61800-3 class C2 EMC rules.
Commissioning and Maintenance Convenience
- Start with the EtherCAT/CiA402 system bus for fast setup.
- Select control mode: U/f, VFCplus, CFC, or ELSM.
- Set PWM to 4, 8, or 16 kHz as needed.
- Use plug connectors for quick line and motor changes.
- The integrated brake chopper reduces extra wiring.
- Optional /CIO21A adds I/O for easy expansion.
- Optional /CID21A and /CES11A simplify encoder integration.
- Keep storage and transport within -25 to +70 °C.
- Protect the unit from condensation at all times.
- Check fan and cabinet airflow during service.
- Use the /L conformal coating option in harsh sites.
Certifications and Standards
- EMC: EN 61800-3, integrated filter, class C2.
- Protection: EN 60529, IP20.
- Pollution Class: IEC 60664-1, class 2; overvoltage category III.
- Storage: EN 60721-3-1 class 1K2, non-condensing.
- Transport: EN 60721-3-2 class 2K3, non-condensing.
- Humidity: EN 60721-3-3 class 3K3, non-condensing.
- Lifecycle: Current SEW-EURODRIVE product line; manual active (last verified: 2026-09).
Packing List
- 1x MDX91A-0025-5E3-4-T00 inverter
- 1x plug connector set for line and motor
- 1x quick start or safety note (as shipped)
- Braking resistor BR.. is optional and not included by default
- Fieldbus and expansion cards are optional and not included by default
- External DC 24 V supply is optional and not included
FAQ
- Q: Which motor power fits this inverter?
- A: It suits an ASM of 0.75 kW at 2.5 A output.
- Q: Can I use it without a braking resistor?
- A: Yes, the integrated brake chopper works with an optional BR.. resistor.
- Q: What is the minimum braking resistance?
- A: Use 95 Ω or higher to protect the chopper.
- Q: Does it support EtherCAT?
- A: Yes, the built-in system bus is EtherCAT / CiA402.
- Q: How do I add PROFINET or EtherNet/IP?
- A: Fit an option card: /CFN21A for PROFINET IO or /DFE32B for EtherNet/IP.
- Q: What is the maximum output frequency?
- A: It depends on mode: 599 Hz in U/f, 250 Hz in VFCplus, 500 Hz in CFC or ELSM.
- Q: Can it run above 40 °C?
- A: Yes, up to +60 °C with derating.
- Q: How much altitude derating applies?
- A: Derate 1% per 100 m between 1000 m and 3800 m.
- Q: Is the DC 24 V supply enough for control?
- A: The built-in 80 W supply is often enough; add external power if needed.
- Q: What wire size fits the plug connectors?
- A: Use 0.25–4 mm² single wire or 0.25–2.5 mm² twin wire.
- Q: Experienced tip: how do I avoid EMC problems?
- A: Keep motor cables short and shield them well; follow class C2 rules.
- Q: Experienced tip: how do I reduce cabinet heat?
- A: Mount units with space between them and respect the 20 W loss per unit.
- Q: Experienced tip: what should I check before power-up?
- A: Check DC 560 V link wiring, 24 V polarity, and plug torque.

















There are no reviews yet.