Product details
Product Overview
The MDA90A-0480-503-X-S00 is a high-power single-axis inverter module from SEW-EURODRIVE. It is part of the MOVIDRIVE® modular drive family. A shared DC link feeds the unit, and it controls one motor. The S00 suffix adds integrated STO (Safe Torque Off). All electrical values match the base model MDA90A-0480-503-X-000. It fits conveyors, hoists, mixers, and heavy single-axis applications up to 22 kW.
- Rated output: 48 A, peak 250% for 1 s
- Typical motor power: 22 kW (ASM)
- Safety: integrated STO to EN 61800-5-2
- Bus: EtherCAT / SBusPLUS on the backplane
- Power: DC link 750–800 V + DC 24 V control (X5)
Order Code Structure
- MDA90A-0480-503-X-S00 — full order code
- MDA90A — MOVIDRIVE modular single-axis inverter series
- 0480 — 48 A rated output current
- 503 — standard technology variant (same as base MDA90A-0480-503-X-000)
- X — base option position
- S00 — integrated STO safety variant
Technical Specifications
- Brand: SEW-EURODRIVE
- Model: MDA90A-0480-503-X-S00
- Series: MOVIDRIVE® modular single-axis module
- Electrical performance
- DC link voltage: 750–800 V DC (400 V line → 750 V; 480 V line → 800 V)
- Rated output current: 48 A
- Overload: 250% of rated current, max 1 second
- Typical ASM motor power: 22 kW
- Max output frequency: U/f 599 Hz · VFCplus 250 Hz · CFC 500 Hz · ELSM 500 Hz
- Control modes: U/f, VFCplus, CFC sensorless vector, ELSM
- Control supply & consumption
- Auxiliary supply: DC 24 V (−10% / +20%), terminal X5
- Standby draw: 4.3 W; green standby mode reduces it by up to 89%
- Encoder supply: peak 1000 mA, terminal X15
- Interfaces & fieldbus
- System bus on backplane X30: EtherCAT / SBusPLUS
- Motor connection: U / V / W; larger frames use X2 copper bars
- Option slot accepts /CES11A, /CID21A, /CIO21A, /CS..A, /L cards
- Safety
- Integrated STO (Safe Torque Off), suffix S00
- Meets EN 61800-5-2
- Environmental & mechanical
- Operating temperature: 0 to +45 °C, no derating
- Storage temperature: −25 to +70 °C, non-condensing
- Protection: IP20
- Base plate width: 90 mm; depth: 355 mm
- EMC: use shielded motor cables, grounded at both ends
Installation Guide
- Mount vertically on a panel. Follow the SEW dimension drawing for this frame size.
- Keep clear air gaps above and below. Never cover the heat sink.
- Connect the DC link from a MDP90A or MDR90B supply module. Never apply AC line directly.
- Wire DC 24 V control power to terminal X5.
- Connect the motor at U / V / W via the X2 copper bars on this frame.
- Use shielded motor cable. Ground the shield at both ends.
- Wire or bridge the STO inputs per EN 61800-5-2 before power-up.
- Torque all power terminals to the value printed in the manual.
Commissioning & Maintenance
- Configure the drive with SEW DriveConfigurator or MOVITOOLS MotionStudio.
- Run motor identification once. CFC gives the best torque dynamics for 22 kW loads.
- Test the STO safety function before releasing the machine.
- Update firmware over the system bus. No extra hardware is required.
- No serviceable parts inside. Blow out dust from the heat sink with dry air.
- Read DC link voltage, current, and fault history from the diagnostic menu.
Compatibility & Expansion
- Works with MOVIDRIVE modular supply modules MDP90A and MDR90B.
- Talks EtherCAT / SBusPLUS through the backplane (X30).
- Add encoder feedback with /CID21A or multi-encoder /CES11A.
- Add digital/analog I/O with /CIO21A. Add extended safety with /CS..A.
- Order the /L version for conformal-coated PCB in dusty or damp cabinets.
- This is a legacy MOVIDRIVE modular unit. New builds use the MOVI-C® platform. We support migration.
Certifications & Standards
- STO function certified to EN 61800-5-2.
- Designed for industrial EMC zones. Ask for the factory test report for full certificate data.
- CE marking follows SEW standard industrial drive practice. Confirm on the nameplate.
Package Contents
- One factory-sealed MDA90A-0480-503-X-S00 single-axis inverter module.
- Digital operating manual (download from SEW-EURODRIVE).
- Mounting sets, option cards, and cables are sold separately.
FAQ
- Q: Can I swap a base MDA90A-0480-503-X-000 for this S00 version?
A: Yes. Electrical data is the same. The S00 adds STO. Wire or bridge the safety terminals before use. - Q: Will it run if I skip the 24 V control supply?
A: No. Terminal X5 must have DC 24 V. The DC link only powers the output stage. - Q: My plant runs 400 V, not 480 V. Is the drive still fine?
A: Yes. 400 V line creates 750 V DC link; 480 V creates 800 V. Both are within spec. - Q: Can I install it next to MOVI-C drives in the same cabinet?
A: Physically yes, but it only works inside the MOVIDRIVE modular platform. Use MOVI-C for new designs. - Q: How do I add extra I/O or encoder feedback?
A: Plug /CIO21A for I/O, or /CID21A and /CES11A for encoders into the option slot. - Q: The cabinet hits 45 °C in summer. Must I derate the 48 A?
A: No derating is needed up to +45 °C. Keep airflow gaps clear and the heat sink clean. - Q: Why is the S00 suffix important when I order spares?
A: It marks the STO safety version. Ordering a different suffix removes the integrated safety function.
















There are no reviews yet.