Product details
Product Overview
The MDA90A-0240-503-X-S00 is a single-axis inverter module from the SEW-EURODRIVE MOVIDRIVE® modular platform.
It runs from a shared DC link and delivers 24 A output, typically driving an 11 kW motor.
The S00 suffix means integrated STO (Safe Torque Off) per EN 61800-5-2 is built in.
A backplane system bus carries EtherCAT and SBusPLUS across the modular drive rack.
Option slots add encoder interfaces, I/O, safety cards, and conformal coating.
Technical Specifications
- Brand: SEW-EURODRIVE
- Model: MDA90A-0240-503-X-S00 (STO variant; base: MDA90A-0240-503-X-000)
- Series: MOVIDRIVE® modular Single-Axis Module
- Device Type: DC-link powered single-axis inverter module
- Electrical Data
- Supply: via DC link (MDP90A / MDR90B supply module required)
- DC link rated voltage: DC 750–800 V (380–400 V line → 750 V; 480–500 V → 800 V)
- Rated output current: 24 A (performance class)
- Typical motor power: 11 kW (ASM, per motor assignment table)
- Overload: 250% of rated current for max 1 s
- Max output frequency: U/f 599 Hz; VFCplus 250 Hz; CFC 500 Hz; ELSM 500 Hz
- Auxiliary supply: DC 24 V (−10%/+20%); standby 4.3 W; energy-saving standby cuts up to 89%
- Encoder supply: peak 1000 mA (X15)
- Motor terminals: U/V/W (sizes 1–2 via terminals; sizes 3–5 via X2 copper bars)
- Safety, I/O & Communication
- Integrated safety: STO per EN 61800-5-2 (S00 variant)
- System bus: EtherCAT / SBusPLUS via backplane (X30)
- Option cards: CES11A (multi-encoder), CID21A (encoder interface), CIO21A (I/O expansion), CS..A (safety), /L (conformal coated PCB)
- Environmental & Mechanical
- Operating temperature: 0 to +45 °C, no derating
- Storage temperature: −25 to +70 °C, non-condensing
- Protection: IP20
- Base plate width: 90 mm; depth: 355 mm
- Lifecycle
- Legacy product of the MOVIDRIVE modular platform
- SEW DriveConfigurator still lists full product data
- Successor platform: MOVI-C® modular system
Installation Guide
- Mount the module on a shared backplane next to the supply unit.
- Connect the DC link busbars as shown in the system manual.
- Wire the motor to U/V/W terminals or X2 copper bars by size.
- Feed DC 24 V to X5 for control power and standby operation.
- Plug encoder and I/O option cards into the option slots.
- Torque all power terminals to the value printed near each connector.
Commissioning & Maintenance
- Configure the axis via SEW DriveConfigurator or the system bus.
- Run motor identification once before first operation.
- Test the STO function during commissioning per EN 61800-5-2.
- Read fault and diagnostic data over the backplane bus.
- Enable energy-saving standby to cut idle consumption by up to 89%.
- Inspect cooling fans and clean air paths annually.
Compatibility Notes
- Requires an MDP90A or MDR90B supply module on the same DC link.
- Works with MOVIDRIVE modular axis modules in a shared rack.
- CES11A and CID21A cards add encoder feedback for closed-loop control.
- CIO21A expands digital and analog I/O beyond the base set.
- CS..A safety cards extend functionality beyond built-in STO.
- For new designs, consider the MOVI-C® successor platform.
Certifications & Standards
- Functional safety: STO per EN 61800-5-2 (integrated, S00 variant).
- Ingress protection: EN 60529, IP20.
- System bus: EtherCAT and SBusPLUS via backplane.
- Conformal coating option: /L variant for harsh environments.
What’s in the Box
- 1× MDA90A-0240-503-X-S00 single-axis module with integrated STO
- 1× Printed installation guide
- 1× Terminal accessories and sealing plugs
Frequently Asked Questions
- Q: Can I connect this module directly to AC mains?
- A: No. It runs from a DC link. You need an MDP90A or MDR90B supply module.
- Q: What does the S00 suffix stand for?
- A: S00 means Safe Torque Off (STO) is integrated per EN 61800-5-2.
- Q: Is this product still in active production?
- A: It is legacy. SEW is transitioning to MOVI-C®, but DriveConfigurator still supports it.
- Q: Can I use it as a standalone drive?
- A: No. It is a modular axis module designed for a shared DC bus rack.
- Q: Which encoder options can I add?
- A: Plug in CES11A (multi-encoder) or CID21A (encoder interface) via the option slot.
- Q: How much power does it save in standby?
- A: Energy-saving standby reduces consumption by up to 89% from the 4.3 W baseline.
- Q: When would I use the 250% overload capability?
- A: For 1-second peak torque demands, such as starting high-inertia loads or heavy conveyors.
















There are no reviews yet.