Product details
Product Overview
The MCC91A-0055-5E3-4-000 is a 2.2 kW monolithic inverter in the space-saving size-0S housing.
Part of the SEW-EURODRIVE MOVITRAC® classic line, it suits conveyors, mixers, and material handling.
Its universal 3×AC 200–500 V input covers 240 V and 480 V grids with one stock item.
A 2.8 kW integrated brake chopper handles overhauling loads without external modules.
Plug-in fieldbus and safety options let you scale the drive as your machine grows.
Technical Specifications
- Brand: SEW-EURODRIVE
- Model: MCC91A-0055-5E3-4-000
- Series: MOVITRAC® classic (MCC91A), size 0S
- Device Type: Cabinet-mounted monolithic inverter drive
- Electrical Data
- Supply: 3×AC 200–500 V, 50–60 Hz ±5%
- Rated motor power (ASM at 400 V): 2.2 kW
- Nominal output current: 5.5 A at 4 kHz PWM
- Apparent output power: 3.8 kVA
- Mains input current: 5.0 A at 400 V
- Overload: 150% IN for 30 s max; 75% IN continuous at 0 Hz
- DC link: nominal DC 560 V, max DC 980 V
- PWM frequency: 4 / 8 / 16 kHz, user adjustable
- Max output frequency: 599 Hz
- Min braking resistance: 90 Ω; chopper continuous power: 2.8 kW
- Power loss: 34 W; 24 V auxiliary consumption: 10 W
- EMC: integrated filter, category C2 per EN 61800-3
- Communication & Safety
- Onboard setpoint: binary and analog; no fieldbus built in
- CFX11A gateway slot: PROFINET, EtherNet/IP, EtherCAT+SBus PLUS, Modbus TCP
- CFC11A module links up to 8 drives on one gateway
- CSO safety option adds STO (Safe Torque Off) up to PL d
- Environmental & Mechanical
- Operating temperature: –10 to +40 °C, non-condensing (IEC 60721-3-3 class 3K22)
- Storage temperature: –25 to +70 °C (IEC 60721-3-1 class 1K21)
- Protection: IP20 per EN 60529 (line and motor connectors plugged in)
- Weight: 1.7 kg
- Terminals: cage-clamp X1/X2, partial spring-loaded
Installation Guide
- Mount vertically on a flat back panel inside a closed cabinet.
- Reserve 50 mm of free space above and below for cooling air.
- Use the cage-clamp X1/X2 terminals for fast, vibration-proof wiring.
- Seat both line and motor connectors to keep the IP20 rating valid.
- Connect a braking resistor (min 90 Ω) for high-inertia stopping.
- Route shielded motor cable separately from signal leads for EMC.
Commissioning & Maintenance
- Key in motor nameplate data via the CBG keypad or SEW PC tool.
- Run auto-tune once; it calibrates the drive to your motor in seconds.
- Lower PWM to 4 kHz for long cables; raise it for quieter operation.
- The CDM11A diagnostic module reads fault history without a PC.
- Vacuum the heat-sink fins and check the fan every six months.
- Only the cooling fan is a scheduled wear part on this drive.
Compatibility Notes
- Drives standard asynchronous and synchronous motors without encoder.
- CFX11A gateway adds PROFINET, EtherNet/IP, EtherCAT, or Modbus TCP.
- CFC11A connects up to eight inverters behind one fieldbus address.
- CSO module retrofits STO PL d; no hardware change to the base unit.
- CBG keypad and CDM11A diagnostics plug into the same option slot.
Certifications & Standards
- EMC: EN 61800-3, category C2 (filter integrated at the factory).
- Ingress protection: EN 60529, IP20.
- Climate: IEC 60721-3-3 class 3K22 (operation), IEC 60721-3-1 class 1K21 (storage).
- Functional safety: STO PL d with the optional CSO module fitted.
What’s in the Box
- 1× MCC91A-0055-5E3-4-000 inverter drive (size 0S)
- 1× Printed installation and quick-start guide
- 1× Terminal label set and sealing plugs
Frequently Asked Questions
- Q: What does the 150% overload rating mean in practice?
- A: The drive delivers 8.25 A for up to 30 seconds, then returns to 5.5 A continuous.
- Q: Why does this model draw 10 W at 24 V while smaller ones draw 1 W?
- A: The larger power stage needs more auxiliary supply for fans and control logic.
- Q: Can it briefly run a 3 kW motor?
- A: No. Match the motor current to 5.5 A. Oversizing the motor risks thermal trips.
- Q: Does it need an external fan at 40 °C ambient?
- A: No. It runs at full rating up to +40 °C with the built-in fan and 50 mm clearance.
- Q: Is it suitable for hoist or lift applications?
- A: Yes with the CSO safety module for STO. Add a holding brake controlled separately.
- Q: Can I copy parameters from one drive to another?
- A: Yes. Save the parameter set to the CBG keypad or SEW PC tool and upload it.
- Q: How do I clear a fault after fixing the cause?
- A: Press the reset key on the keypad, toggle the digital reset input, or cycle power.















There are no reviews yet.