Product details
Product Overview
The MDA90A-0020-503-X-S00 is a single-axis inverter module built by SEW-EURODRIVE. It belongs to the MOVIDRIVE® modular drive platform. The unit draws power from a shared DC link and drives one motor. It carries the integrated STO (Safe Torque Off) function, identified by the S00 suffix. Electrical data matches the base model MDA90A-0020-503-X-000. It suits conveyors, fans, pumps, and single-axis machine tasks.
- Output current: 2 A rated, up to 250% for 1 s
- Typical motor power: 0.55 kW (ASM)
- Safety: integrated STO per EN 61800-5-2
- System bus: EtherCAT / SBusPLUS via backplane
- Supply: DC link 750–800 V + DC 24 V control (X5)
Order Code Breakdown
- MDA90A-0020-503-X-S00 — full order code
- MDA90A — MOVIDRIVE modular single-axis inverter series
- 0020 — 2 A rated output current
- 503 — standard technology variant (same as base MDA90A-0020-503-X-000)
- X — base option position
- S00 — integrated STO safety variant
Technical Specifications
- Brand: SEW-EURODRIVE
- Model: MDA90A-0020-503-X-S00
- Series: MOVIDRIVE® modular single-axis module
- Electrical performance
- DC link voltage: 750–800 V DC (400 V line → 750 V; 480 V line → 800 V)
- Rated output current: 2 A
- Overload capacity: 250% of rated current, max 1 second
- Typical ASM motor power: 0.55 kW
- Output frequency: U/f 599 Hz · VFCplus 250 Hz · CFC 500 Hz · ELSM 500 Hz
- Control modes: U/f, VFCplus, CFC (sensorless vector), ELSM
- Control voltage & consumption
- Auxiliary supply: DC 24 V (−10% / +20%), terminal X5
- Standby power: 4.3 W; energy-saving standby cuts use by up to 89%
- Encoder supply: peak 1000 mA, terminal X15
- Interfaces & communication
- System bus via backplane X30: EtherCAT / SBusPLUS
- Motor terminals: U / V / W
- Option slot for /CES11A, /CID21A, /CIO21A, /CS..A, /L cards
- Safety function
- Integrated STO (Safe Torque Off), suffix S00
- Compliant with EN 61800-5-2
- Environmental & mechanical
- Operating temperature: 0 to +45 °C, no derating
- Storage temperature: −25 to +70 °C, non-condensing
- Protection rating: IP20
- Base plate width: 60 mm; depth: 355 mm
- EMC: install with shielded motor cables per SEW guidelines
Installation Guide
- Mount the unit vertically on a panel or DIN rail. Follow the SEW dimension drawing.
- Leave free space above and below for cooling airflow. Do not block the heat sink.
- Feed the DC link from a supply module (MDP90A / MDR90B). Do not connect AC line directly.
- Connect DC 24 V control power to terminal X5.
- Wire the motor to U / V / W. Use shielded cable and ground both ends.
- Wire the STO safety inputs per EN 61800-5-2, or bridge them if unused.
- Tighten all terminals to the torque value in the manual.
Commissioning & Maintenance
- Set parameters with SEW DriveConfigurator or MOVITOOLS MotionStudio.
- Run motor auto-tuning once. CFC and VFCplus give the best dynamic response.
- Check STO wiring and safety function before first machine run.
- Update firmware through the system bus. No special adapter is needed.
- No wearing parts inside. Clean the heat sink with a dry cloth when needed.
- Read DC link voltage and fault codes from the diagnostic menu.
Compatibility & Expansion
- Pairs with MOVIDRIVE modular supply modules MDP90A and MDR90B.
- Communicates over EtherCAT / SBusPLUS through the backplane (X30).
- Add encoders with /CID21A (single encoder) or /CES11A (multi-encoder).
- Add I/O points with /CIO21A; add higher safety functions with /CS..A cards.
- Order the /L variant for conformal-coated PCB in harsh environments.
- This is a legacy MOVIDRIVE modular unit. New designs use the MOVI-C® platform. Migration support is available.
Certifications & Standards
- STO safety function certified to EN 61800-5-2.
- Built for industrial EMC environments. Request the factory test report for full certificate details.
- CE marking follows SEW standard industrial drive practice. Verify on the unit nameplate.
Package Contents
- One factory-sealed MDA90A-0020-503-X-S00 single-axis inverter module.
- Digital operating instructions (download from SEW-EURODRIVE).
- Mounting material, option cards, and cables are ordered separately.
FAQ
- Q: Can I replace a base MDA90A-0020-503-X-000 with this S00 unit?
A: Yes. Electrical data is identical. The S00 adds integrated STO. Wire or bridge the safety inputs before use. - Q: Does it work without the 24 V control supply?
A: No. Terminal X5 needs DC 24 V. The DC link powers only the output stage. - Q: My mains is 400 V, not 480 V. Is that a problem?
A: No. 400 V line gives 750 V DC link; 480 V gives 800 V. Both sit inside the allowed range. - Q: Can I mix it with MOVI-C components?
A: Use it within the MOVIDRIVE modular platform only. Choose MOVI-C for new machine designs. - Q: How do I add extra I/O or a second encoder?
A: Plug /CIO21A for I/O, or /CID21A and /CES11A for encoders into the option slot. - Q: The cabinet reaches 45 °C. Will the drive derate?
A: No derating is required up to +45 °C. Keep airflow gaps clear and do not cover the heat sink. - Q: What does the S00 suffix mean for spare parts?
A: It marks the STO safety variant. Always order the exact same suffix to keep the safety function intact.
















There are no reviews yet.