Product details
Product Overview
- The MCC91A-0240-5E3-4-000 is a compact cabinet-mounted inverter made by SEW-EURODRIVE.
- It belongs to the MOVITRAC® classic (MCC91A) family, size 0L.
- It drives asynchronous and synchronous motors without encoder feedback.
- Rated at 12.5 kW and 24.0 A, it runs on 3×AC 380–500 V mains.
- An integrated brake chopper handles regenerative energy out of the box.
- A plug-in CFX11A gateway slot adds PROFINET, EtherNet/IP, EtherCAT, or Modbus TCP.
- An optional CSO safety module delivers Safe Torque Off up to PL d.
Technical Specifications
- Brand: SEW-EURODRIVE
- Model: MCC91A-0240-5E3-4-000
- Series: MOVITRAC® classic (MCC91A), size 0L
- Model code structure:
- MCC91A → MOVITRAC® classic series
- 0240 → 24.0 A nominal output current
- 5E3 → factory configuration code
- 4 → enclosure / option code
- 000 → standard configuration, no add-on options
- Electrical ratings:
- Supply voltage: 3×AC 380–500 V, 50–60 Hz ±5%
- Rated motor power: 12.5 kW (ASM at 400 V)
- Nominal output current: 24.0 A at 4 kHz PWM
- Apparent output power: 16.8 kVA
- Mains input current: 21.6 A at 400 V
- Overload capacity: 150% IN for max 30 s; 75% IN continuous at 0 Hz
- DC link voltage: 560 V nominal, 980 V maximum
- PWM frequency: 4 / 8 / 16 kHz, adjustable
- Maximum output frequency: 599 Hz
- Integrated brake chopper: 16.8 kW continuous, min resistor 24 Ω
- Power section loss: 236 W
- 24 V control consumption: 20 W
- EMC filter: category C2 per EN 61800-3
- Environmental ratings:
- Operating temperature: -10 to +40 °C, non-condensing (IEC 60721-3-3 class 3K22)
- Storage temperature: -25 to +70 °C, non-condensing (IEC 60721-3-1 class 1K21)
- Humidity: non-condensing
- Protection rating: IP20 per EN 60529 (with connectors plugged in)
- Physical data:
- Weight: 11.0 kg
- Enclosure: monolithic, cabinet mount, size 0L
Installation Guide
- Mount the unit inside a control cabinet on a flat vertical panel.
- Keep clear space above and below for cooling airflow.
- Wire mains to X1 and motor to X2 using cage-clamp terminals.
- Connect a braking resistor if your load regenerates often.
- Plug in the CFX11A gateway before applying power.
- Fit the CSO safety module only if you need the STO function.
- Tighten all terminals to the torque values in the manual.
Commissioning & Maintenance
- Set up the drive with the CBG keypad or CDM11A diagnostic module.
- Enter motor nameplate data via keypad or fieldbus.
- Run the auto-tune routine for best current control.
- Set ramp times, limits, and I/O mapping to match your process.
- No fan or wearable parts sit inside, so maintenance stays minimal.
- Check terminal tightness once per year.
- Keep cooling fins clean and free of obstruction.
Compatibility
- Works with asynchronous and synchronous motors without encoder.
- CFX11A gateway supports PROFINET, EtherNet/IP, EtherCAT+SBus PLUS, Modbus TCP.
- CFC11A module links up to 8 inverters on one gateway.
- CSO safety option adds Safe Torque Off up to PL d.
- CBG keypad and CDM11A diagnostic module plug in directly.
Certifications & Standards
- EMC: integrated filter meets EN 61800-3 category C2.
- Protection: IP20 per EN 60529.
- Environmental: IEC 60721-3-3 class 3K22, IEC 60721-3-1 class 1K21.
- Safety: STO PL d achievable with optional CSO module.
Package Contents
- 1× MCC91A-0240-5E3-4-000 inverter, size 0L
- Integrated EMC filter and brake chopper (factory installed)
- Quick-start documentation
- Note: CFX11A gateway, CSO module, CBG keypad, CDM11A sold separately
Frequently Asked Questions
- Q: Can I use this drive with a permanent magnet synchronous motor?
A: Yes. It controls both asynchronous and synchronous motors without an encoder. - Q: Do I need an external brake chopper for lifting applications?
A: No. The integrated 4Q brake chopper handles regenerative energy up to 16.8 kW. Add an external resistor only for high duty cycles. - Q: How do I connect it to my PLC?
A: Plug a CFX11A gateway into the onboard slot. Pick the protocol matching your PLC: PROFINET, EtherNet/IP, EtherCAT, or Modbus TCP. - Q: Can multiple drives share one fieldbus gateway?
A: Yes. Add a CFC11A module. One gateway then controls up to eight drives. - Q: What is STO and does the drive include it?
A: STO means Safe Torque Off, a safety function. The base unit does not include it. Add the optional CSO module to reach PL d. - Q: The drive trips on overvoltage during deceleration. What should I do?
A: Regenerative energy raises the DC link. Increase deceleration time or fit a braking resistor (min 24 Ω) across the brake chopper. - Q: Can I mount it on the wall without a cabinet?
A: No. IP20 rating requires cabinet mounting. Protect it from dust and dripping water. - Q: Does it work on 60 Hz mains?
A: Yes. It accepts 50–60 Hz ±5% on a 380–500 V three-phase supply.















There are no reviews yet.