Product details
Product Overview
The MCC91A-0032-5E3-4-000 delivers 1.1 kW of motor control in a compact size-0S frame.
SEW-EURODRIVE built this MOVITRAC® classic inverter for conveyor, fan, and pump duty.
A universal 3×AC 200–500 V input lets one part number serve both 240 V and 480 V sites.
The onboard brake chopper sends regenerative energy to a resistor with no add-on module.
Cage-clamp terminals cut wiring time, and a plug-in slot adds fieldbus when you need it.
Technical Specifications
- Brand: SEW-EURODRIVE
- Model: MCC91A-0032-5E3-4-000
- Series: MOVITRAC® classic (MCC91A), size 0S
- Device Type: Cabinet-mounted monolithic inverter drive
- Electrical Data
- Supply: 3×AC 200–500 V, 50–60 Hz ±5%
- Rated motor power (ASM at 400 V): 1.1 kW
- Nominal output current: 3.2 A at 4 kHz PWM
- Apparent output power: 2.2 kVA
- Mains input current: 2.9 A at 400 V
- Overload: 150% IN for 30 s max; 75% IN continuous at 0 Hz
- DC link: nominal DC 560 V, max DC 980 V
- PWM frequency: 4 / 8 / 16 kHz, user adjustable
- Max output frequency: 599 Hz
- Min braking resistance: 90 Ω; chopper continuous power: 1.7 kW
- Power loss: 19 W; 24 V auxiliary consumption: 1 W
- EMC: integrated filter, category C2 per EN 61800-3
- Communication & Safety
- Onboard setpoint: binary and analog; no fieldbus built in
- CFX11A gateway slot: PROFINET, EtherNet/IP, EtherCAT+SBus PLUS, Modbus TCP
- CFC11A module links up to 8 drives on one gateway
- CSO safety option adds STO (Safe Torque Off) up to PL d
- Environmental & Mechanical
- Operating temperature: –10 to +40 °C, non-condensing (IEC 60721-3-3 class 3K22)
- Storage temperature: –25 to +70 °C (IEC 60721-3-1 class 1K21)
- Protection: IP20 per EN 60529 (line and motor connectors plugged in)
- Weight: 1.7 kg
- Terminals: cage-clamp X1/X2, partial spring-loaded
Installation Guide
- Mount vertically on a flat panel inside a closed control cabinet.
- Keep 50 mm clear above and below the drive for cooling airflow.
- Wire line and motor leads through the cage-clamp X1/X2 terminals.
- Fit both power connectors to maintain the IP20 protection rating.
- Add a braking resistor (min 90 Ω) for high-inertia or overhauling loads.
- Use shielded motor cable, grounded at both ends, to meet EMC class C2.
Commissioning & Maintenance
- Enter motor nameplate data with the CBG keypad or SEW PC software.
- Run the auto-tune routine once so the drive matches your motor.
- Set PWM to 4 kHz for long cable runs; use 8 or 16 kHz for low noise.
- The plug-in CDM11A diagnostic module speeds up fault reading on site.
- Clean air vents and inspect the cooling fan every six months.
- No wear parts need routine replacement except the cooling fan.
Compatibility Notes
- Controls standard asynchronous and synchronous motors without encoder.
- Add CFX11A to join PROFINET, EtherNet/IP, EtherCAT, or Modbus TCP networks.
- One CFC11A gateway serves up to eight inverters and cuts fieldbus cost.
- CSO safety module retrofits STO PL d without replacing the base drive.
- CBG keypad and CDM11A diagnostics share the same option slot family.
Certifications & Standards
- EMC: EN 61800-3, category C2 (integrated filter fitted).
- Ingress protection: EN 60529, IP20.
- Climate: IEC 60721-3-3 class 3K22 (operation), IEC 60721-3-1 class 1K21 (storage).
- Functional safety: STO PL d achievable with optional CSO module.
What’s in the Box
- 1× MCC91A-0032-5E3-4-000 inverter drive (size 0S)
- 1× Printed installation and quick-start guide
- 1× Terminal label set and sealing plugs
Frequently Asked Questions
- Q: How does this model differ from the 0.37 kW version?
- A: It outputs 3.2 A versus 1.6 A and handles 1.1 kW motors. The frame stays size 0S.
- Q: Can I run two motors in parallel from one drive?
- A: Yes, for V/f mode only. Sum the motor currents and stay under 3.2 A total.
- Q: Which braking resistor should I pair with it?
- A: Use a resistor of at least 90 Ω rated for your duty cycle; 1.7 kW continuous max.
- Q: Does it support sensorless vector control?
- A: Yes. Select V/f or sensorless vector in the keypad menu after auto-tune.
- Q: Can I mount two units side by side with no gap?
- A: Yes, zero side clearance is allowed. Keep 50 mm free above and below.
- Q: How do I protect the motor against overload?
- A: Set the motor current limit in the parameters; the drive trips on I²t thermal overload.
- Q: Is it compatible with SEW MOVIMOT gear motors?
- A: Yes. Enter the MOVIMOT nameplate data and run auto-tune for best results.
















There are no reviews yet.