Product details
Product Overview
The MC07B 0011-2B1-4-00 is a bookshelf-format inverter from the SEW-EURODRIVE MOVITRAC® B family.
It runs on a single-phase 200–240 V supply and delivers 1.1 kW / 5.7 A to a three-phase motor.
CANopen comes built in, so you can connect to a fieldbus network right out of the box.
Choose U/f or sensorless vector (VFC) control to match your application.
Cold-plate technology and forced-air cooling keep the size-0L frame compact and cool.
Technical Specifications
- Brand: SEW-EURODRIVE
- Model: MC07B 0011-2B1-4-00 (part no. 828 496 2)
- Series: MOVITRAC® B Standard Inverter, size 0L
- Device Type: Bookshelf cabinet inverter, single-phase input
- Electrical Data
- Supply: 1×AC 200–240 V, 50/60 Hz ±5%
- Rated motor power: 1.1 kW
- Rated output current: 5.7 A
- Output voltage: 3× 0 – Vline
- Overload: 125% IN continuous; 150% IN for min 60 s
- Max output frequency: 599 Hz
- DC bus: max permitted DC 485 V
- Integrated brake chopper (4Q); min braking resistance: 27 Ω
- Power loss: 70 W at 100% rated load
- Control modes: U/f, VFC (sensorless vector)
- I/O & Communication
- Built-in fieldbus: CANopen (integrated on base unit)
- Digital I/O: 6 programmable inputs, 2 programmable outputs, 1 relay output
- Analog: 1 setpoint input; removable signal terminals
- Option slots: DFE32B (PROFINET), DFE33B (Modbus TCP/EtherNet/IP), DFE24B/FSE24B (EtherCAT), DFP21B (PROFIBUS), DFD11B (DeviceNet), FSC11B/12B (SBus/RS485)
- Safety note: STO not supported on single-phase 230 V units
- Environmental & Mechanical
- Operating temperature: –10 to +50 °C; derate 2.5% IN/K (40–50 °C), 3% IN/K (50–60 °C)
- Storage temperature: –25 to +75 °C
- Climate class: EN 60721-3-3 class 3K3
- Protection: IP20
- Dimensions (H×W×D): 273.5 × 80 × 163.5 mm
- Weight: 2.2 kg
Installation Guide
- Mount vertically on a panel or DIN rail inside a closed cabinet.
- Allow 50 mm clearance above and below for forced-air cooling.
- Connect the single-phase line to L1/L2/N per the wiring diagram.
- Use the removable signal terminals for fast control wiring.
- Fit a braking resistor of at least 27 Ω if your load regenerates.
- Bond the cold plate to a metal mounting surface for best heat transfer.
Commissioning & Maintenance
- Set motor nameplate data and choose U/f or VFC mode via the keypad.
- Run the motor auto-tune routine once for optimal VFC performance.
- Map the six digital inputs to your machine logic in the parameter menu.
- Read fault codes and parameter sets over CANopen without a laptop.
- Clean the air path and check the cooling fan every six months.
- Only the cooling fan is a scheduled wear part on this model.
Compatibility Notes
- Drives standard three-phase asynchronous and synchronous motors.
- CANopen is onboard; add DFE32B/DFE33B/DFE24B for Ethernet-based networks.
- DFP21B and DFD11B options add PROFIBUS DPV1 and DeviceNet.
- Safety modules DFS11B/DFS21B exist but do not apply to this single-phase unit.
- FSC11B/FSC12B add SBus and RS485 for legacy system integration.
Certifications & Standards
- EMC: integrated filter per EN 61800-3.
- Ingress protection: EN 60529, IP20.
- Climate: EN 60721-3-3 class 3K3.
- Fieldbus: CANopen CiA 402 drive profile (built in).
What’s in the Box
- 1× MC07B 0011-2B1-4-00 inverter drive (size 0L)
- 1× Removable signal terminal block
- 1× Printed installation and quick-start guide
Frequently Asked Questions
- Q: Does this model support Safe Torque Off (STO)?
- A: No. Single-phase 230 V MOVITRAC B units do not support STO. Pick a three-phase model if safety is required.
- Q: Can I power it from a 100/110 V grid?
- A: No. It needs 200–240 V single-phase. A 110 V supply triggers an undervoltage fault.
- Q: Is a fieldbus interface included?
- A: Yes, CANopen is built in. Add DFE32B, DFE33B, or DFE24B for PROFINET, EtherNet/IP, or EtherCAT.
- Q: What braking resistor can I use?
- A: Use a resistor of at least 27 Ω. A lower value damages the integrated brake chopper.
- Q: How does it behave above 40 °C?
- A: It derates 2.5% per kelvin from 40 to 50 °C and 3% per kelvin from 50 to 60 °C.
- Q: What is cold-plate technology?
- A: The power stage sits on a metal cold plate. You can mount it to a cabinet wall or external heat sink.
- Q: How many I/O points are available?
- A: Six digital inputs, two digital outputs, one relay output, and one analog input.















There are no reviews yet.