Product details
Product Overview
The MCC91A-0016-5E3-4-000 is a compact monolithic inverter from SEW-EURODRIVE.
Part of the MOVITRAC® classic family, it controls asynchronous and synchronous motors without encoder.
It delivers 0.37 kW rated power on a universal 3×AC 200–500 V supply for global machines.
A built-in brake chopper absorbs regenerative energy with no extra module.
The size 0S housing fits tight cabinet layouts and ships ready for panel mount.
Technical Specifications
- Brand: SEW-EURODRIVE
- Model: MCC91A-0016-5E3-4-000
- Series: MOVITRAC® classic (MCC91A), size 0S
- Device Type: Cabinet-mounted monolithic inverter drive
- Electrical Data
- Supply: 3×AC 200–500 V, 50–60 Hz ±5%
- Rated motor power (ASM at 400 V): 0.37 kW
- Nominal output current: 1.6 A at 4 kHz PWM
- Apparent output power: 1.1 kVA
- Mains input current: 1.4 A at 400 V
- Overload: 150% IN for 30 s max; 75% IN continuous at 0 Hz
- DC link: nominal DC 560 V, max DC 980 V
- PWM frequency: 4 / 8 / 16 kHz, user adjustable
- Max output frequency: 599 Hz
- Min braking resistance: 90 Ω; chopper continuous power: 1.1 kW
- Power loss: 7 W; 24 V auxiliary consumption: 1 W
- EMC: integrated filter, category C2 per EN 61800-3
- Communication & Safety
- Onboard setpoint: binary and analog; no fieldbus built in
- CFX11A gateway slot: PROFINET, EtherNet/IP, EtherCAT+SBus PLUS, Modbus TCP
- CFC11A module links up to 8 drives on one gateway
- CSO safety option adds STO (Safe Torque Off) up to PL d
- Environmental & Mechanical
- Operating temperature: –10 to +40 °C, non-condensing (IEC 60721-3-3 class 3K22)
- Storage temperature: –25 to +70 °C (IEC 60721-3-1 class 1K21)
- Protection: IP20 per EN 60529 (line and motor connectors plugged in)
- Weight: 1.7 kg
- Terminals: cage-clamp X1/X2, partial spring-loaded
Installation Guide
- Mount vertically inside a closed control cabinet on a flat panel.
- Keep 50 mm free above and below the unit for cooling air.
- Use the cage-clamp X1/X2 terminals for fast, tool-friendly wiring.
- Plug in both line and motor connectors to keep the IP20 rating.
- Connect an external braking resistor (min 90 Ω) if your load regenerates.
- Use shielded motor cable and ground both ends to meet EMC class C2.
Commissioning & Maintenance
- Enter motor nameplate data via the CBG keypad or SEW PC software.
- Run the auto-tune routine once; it matches the drive to your motor.
- Set PWM to 4 kHz for long motor cables; raise to 8 or 16 kHz for quiet operation.
- The plug-in CDM11A diagnostic module speeds up fault tracing on site.
- Clean the air vents and check the fan every six months in normal duty.
- No wear parts require routine replacement beyond the cooling fan.
Compatibility Notes
- Drives standard asynchronous and synchronous motors without encoder feedback.
- Add CFX11A to connect to PROFINET, EtherNet/IP, EtherCAT, or Modbus TCP networks.
- One CFC11A gateway serves up to eight inverters, cutting fieldbus cost.
- CSO safety module retrofits STO PL d without changing the base drive.
- CBG keypad and CDM11A diagnostics share the same option slot family.
Certifications & Standards
- EMC: EN 61800-3, category C2 (integrated filter fitted).
- Ingress protection: EN 60529, IP20.
- Climate: IEC 60721-3-3 class 3K22 (operation), IEC 60721-3-1 class 1K21 (storage).
- Functional safety: STO PL d achievable with optional CSO module.
What’s in the Box
- 1× MCC91A-0016-5E3-4-000 inverter drive (size 0S)
- 1× Printed installation and quick-start guide
- 1× Terminal label set and sealing plugs
Frequently Asked Questions
- Q: Can I use this with a 0.55 kW motor?
- A: No. Match drive current to the motor nameplate. Select the next frame size.
- Q: Is a fieldbus port built into the unit?
- A: No. Plug in the CFX11A gateway for PROFINET, EtherNet/IP, EtherCAT, or Modbus TCP.
- Q: Do I need to buy a separate brake chopper?
- A: No. The chopper is integrated. You only add an external resistor of at least 90 Ω.
- Q: Will it run on both 240 V and 480 V grids?
- A: Yes. The wide 200–500 V input covers both without any jumper change.
- Q: How do I add Safe Torque Off to this drive?
- A: Install the optional CSO safety module. It provides STO up to PL d.
- Q: My motor cable run is 50 m. Is that acceptable?
- A: Use shielded cable and fit a motor output filter. Keep PWM at 4 kHz.
- Q: Can I group several drives on one fieldbus node?
- A: Yes. The CFC11A module connects up to eight inverters to a single CFX11A gateway.
















There are no reviews yet.