Product details
Product Overview
MCC91A-0010-5E3-4-000 is a compact inverter from SEW-EURODRIVE. It belongs to the MOVITRAC classic series. This size 0S unit delivers 0.25 kW for asynchronous and synchronous motors. It works without an encoder. A 3 x AC 200-500 V universal supply powers the drive. An integrated brake chopper (4Q) saves cabinet space. The monolithic housing fits machine-level mounting. Cage-clamp terminals X1/X2 speed up wiring. A plug-in gateway slot adds fieldbus connectivity when needed. An optional CSO module enables STO PL d safety. An integrated EMC filter meets category C2 limits.
Technical Specifications
- Brand: SEW-EURODRIVE
- Model: MCC91A-0010-5E3-4-000
- Series: MOVITRAC classic (MCC91A)
- Module type: Compact monolithic inverter, size 0S
- Rated motor power: 0.25 kW (ASM at 400 V)
- Supply voltage: 3 x AC 200-500 V, 50-60 Hz +/-5%
- Nominal output current: 1.0 A at 4 kHz PWM
- Apparent output power: 0.7 kVA
- Nominal mains input current: 0.9 A at 400 V
- Overload capacity: 150% I_N for 30 s; 75% x I_N continuous at 0 Hz
- DC link voltage: 560 V nominal; 980 V maximum
- PWM frequency: 4 / 8 / 16 kHz, adjustable
- Maximum output frequency: 599 Hz
- Minimum braking resistance: 90 Ω
- Brake chopper continuous power: 0.7 kW
- Power loss: 7 W in the power section; 1 W at 24 V
- Measurement range: 0 to 599 Hz output frequency
- Frequency response: Stable control up to 599 Hz
- Sensitivity: Fine analog and binary setpoint response onboard
- Linearity: Smooth speed control across the full range
- Resolution: Adjustable 4 / 8 / 16 kHz PWM steps
- Temperature range: -10 to +40 °C operating; -25 to +70 °C storage
- Environmental tolerance: Class 3K22 / 1K21, non-condensing
- Noise immunity: Integrated EMC filter, category C2 per EN 61800-3
- Protection rating: IP20 per EN 60529, with line and motor connectors plugged in
- Weight: 1.7 kg
Installation Guide
- Mount the unit inside a cabinet. Keep the IP20 rating in mind.
- Use the cage-clamp terminals X1/X2 for line and motor cables.
- Plug in both power connectors before you power up.
- Respect the 90 Ω minimum braking resistance.
- Keep airflow clear around the monolithic housing.
- Wire the 3 x AC 200-500 V supply within +/-5% frequency tolerance.
Setup and Maintenance
- Set binary or analog setpoints directly on board. No extra module is needed.
- Add the CBG keypad or CDM11A diagnostic module for fast commissioning.
- Adjust PWM frequency to 4, 8, or 16 kHz to match your noise and load needs.
- The plug-in gateway slot lets you add fieldbus control later.
- Few wearing parts and clear terminals keep service simple.
- Check terminals and airflow at regular intervals.
Compatibility
- Runs asynchronous and synchronous motors without an encoder.
- Accepts a CFX11A gateway for PROFINET, EtherNet/IP, EtherCAT/SBus PLUS, or Modbus TCP.
- Supports a CFC11A communication module. One gateway can serve up to 8 inverters.
- Works with the optional CSO safety module for STO PL d.
- Fits the MOVITRAC classic size 0S / 0L enclosure family.
Certifications and Standards
- EMC filter limit value category C2 per EN 61800-3.
- Protection rating IP20 per EN 60529.
- Climate class 3K22 and 1K21 per IEC 60721-3.
- Optional STO PL d safety through the CSO module.
Packing List
- 1 x MCC91A-0010-5E3-4-000 inverter
- 1 x terminal and connector set
- 1 x quick start guide
- Optional items ordered separately: CFX11A gateway, CSO module, CDM11A module, CBG keypad
FAQ
Q: Can this inverter run without an encoder?
A: Yes. It controls asynchronous and synchronous motors without an encoder. This keeps wiring simple and cuts cost.
Q: How do I add PROFINET or EtherNet/IP?
A: Order the CFX11A gateway. It plugs into the gateway slot. One gateway can serve up to 8 inverters with the CFC11A module.
Q: What supply voltage does it accept?
A: It takes 3 x AC 200-500 V at 50-60 Hz. Stay within +/-5% frequency tolerance.
Q: Does it include a brake chopper?
A: Yes. The 4Q brake chopper is built in. It handles 0.7 kW continuous. Use a braking resistor of at least 90 Ω.
Q: From experience, what should I check first during startup?
A: Confirm both power connectors sit fully in place. The IP20 rating depends on this. Then check setpoints and PWM setting. Most startup issues trace back to loose terminals.
Q: How much space do I need in the cabinet?
A: The unit is compact and weighs 1.7 kg. Leave room for airflow on all sides. Keep the cabinet within -10 to +40 °C.
Q: Can I add STO safety later?
A: Yes. The optional CSO module adds STO PL d. You can fit it during commissioning or as an upgrade.
Q: What do field engineers commonly overlook?
A: They often forget the EMC filter category C2 limits. Keep motor cables short. Also check the 150% overload window of 30 s before you set heavy loads.