Product details
Product Overview
FCST1050L is an analog mass flow controller from Fujikin, part of the FCST T1000 Series. It covers 31 to 50 SLM of nitrogen and suits high-volume analog lines. The body is compact, so it fits tight gas panels. A bellows-sealed diaphragm valve gives stable control. Choose a rubber or metal seal to match your leak target. This unit fits CVD, PVD, etching, and gas cabinet work where cost and simplicity matter.
- Core role: simple analog flow control for large lines.
- Best fit: panels that already use 0-5 VDC signals.
- Value: low cost per point across many tools.
Key Benefits
- Compact size saves space in dense gas cabinets.
- Clear accuracy at ±2% FS on the 31-50 SLM band.
- Fast response within 2 seconds on the high range.
- Strong turndown from 2% to 100% of full scale.
- Seal choice lets you set your own leak limit.
- RoHS and CE meet common plant rules.
Technical Specifications
- Brand: Fujikin
- Model: FCST1050L
- Series: FCST T1000 Series, FCS-T1000L Analog Economy
- Module type: analog mass flow controller
- Full-scale flow range: 31 to 50 SLM N2
- Accuracy: ±1% FS for 10 SCCM-30 SLM; ±2% FS for 31-50 SLM; guaranteed 15-35°C
- Repeatability: ±0.2% FS
- Response time: 1 second or less for 10 SCCM-30 SLM; 2 seconds or less for 31-50 SLM
- Control range: 2% to 100% FS
- Gas type: customer-specified; N2, Ar, He, H2, O2 and common semiconductor gases
- Max operating pressure: 400 kPaG
- Required differential: 50 to 300 kPa
- Wetted materials: SUS316L stainless steel, PCTFE seats
- Seals: FKM rubber standard; metal seal option
- Valve type: bellows-sealed diaphragm valve, normally open or closed
- Electrical interface: analog 0-5 VDC only
- Power supply: ±15 VDC
- Dimensions: 125 H × 124 W × 77 D mm
- Leak integrity: 1×10⁻⁷ Pa·m³/s He with rubber seal; 1×10⁻¹¹ Pa·m³/s He with metal seal
Measurement and Environment Performance
- Measuring range: 31 to 50 SLM N2, 2-100% FS control band
- Frequency response: 2 seconds or less on the high range
- Sensitivity: ±0.2% FS repeatability
- Linearity: held inside the ±2% FS accuracy
- Resolution: fine steps across the 2-100% band
- Temperature range: 5°C to 50°C ambient
- Environment resistance: FKM seals handle many process gases
- Interference resistance: simple analog loop limits noise paths
Installation Guide
- Space: the compact body fits small panels.
- Pressure: keep inlet at or below 400 kPaG.
- Differential: hold 50 to 300 kPa for rated control.
- Power: feed clean ±15 VDC to the unit.
- Signal: use a stable 0-5 VDC source.
- Leak check: test joints at working pressure before gas on.
- Ambient: keep the area between 5°C and 50°C.
Setup and Maintenance Ease
- Quick setup: the analog loop needs little tuning.
- Few parts: a simple valve design cuts spare stock.
- Seal choice: swap rubber for metal when leak limits tighten.
- Service access: the compact body is easy to reach.
- Stable flow: the diaphragm valve reduces drift.
Compatibility Notes
- Controllers: works with any 0-5 VDC analog host.
- Gases: order the unit for your process gas.
- Seal choice: FKM standard, metal seal optional.
- Retrofits: a good drop-in for older analog MFCs.
- Panels: fits standard gas cabinet layouts.
Certification and Compliance
- CE marked for European requirements.
- RoHS compliant for restricted substances.
- Leak spec down to 1×10⁻¹¹ Pa·m³/s He with metal seal.
Packing List
- FCST1050L analog mass flow controller, one unit
- Calibration certificate
- Interface pinout sheet
- Safety and handling notes
- Protective shipping caps
FAQ
Q: Does this unit support digital buses?
A: No. It offers a 0-5 VDC analog link only.
Q: What power does it need?
A: A clean ±15 VDC supply.
Q: How tight is the leak spec?
A: The metal seal option reaches 1×10⁻¹¹ Pa·m³/s He.
Q: Can I use it for hydrogen?
A: Yes. Order the unit set for H2 gas.
Q: What differential does it need?
A: Keep 50 to 300 kPa across the unit.
Q: From experience, what causes flow drift?
A: Inlet pressure swings often shift readings. Hold pressure steady first.
Q: Any tip for the analog signal?
A: Use shielded cable and a stable source to cut noise.
Q: Why does my unit read low at startup?
A: Warm-up time matters. Let the unit settle before trusting data.
Q: Can I swap seals in the field?
A: Field changes are possible. Follow the Fujikin service guide closely.













There are no reviews yet.