Product details
FCST1200MF High-Flow Metal-Seal MFC by Fujikin
The FCST1200MF is a high-flow mass flow controller from Fujikin. It belongs to the FCST T1200 Series, the FCS-T1200MF high-flow metal-seal line. Full-scale flow reaches 51 to 150 SLM in N2 equivalent. This range suits bulk gas delivery and large chamber purge. The unit uses a metal seal with an Au gasket. Wetted parts are SUS316L stainless steel with PCTFE seats. A bellows-sealed metal diaphragm valve handles control. Accuracy holds at ±1% FS across 15 to 35°C. Response time stays at 3 seconds or less. The body measures 154 × 192.4 × 116 mm. Analog and digital interfaces cover most tool platforms.
Key Strengths
- High flow: full scale up to 150 SLM, N2 equivalent.
- Clean service: metal seal with Au gasket and SUS316L body.
- Fast response: 3 seconds or less.
- Stable accuracy: ±1% FS from 15 to 35°C.
- Low leak: 1×10⁻¹¹ Pa·m³/s He or better.
- Flexible valve: normally open or normally closed.
- Easy fit: 3/8 UJR or F900 fittings.
Technical Data
- Brand: Fujikin
- Model: FCST1200MF
- Series: FCST T1200 Series, FCS-T1200MF High Flow, Metal Seal
- Product type: high-flow metal-seal mass flow controller
- Measurement range: 51 to 150 SLM (N2 equivalent)
- Accuracy: ±1% FS, guaranteed from 15 to 35°C
- Repeatability: ±0.2% FS
- Response time: 3 seconds or less
- Linearity: covered by the accuracy spec
- Hysteresis: covered by the accuracy spec
- Resolution and turndown: control range 2 to 100% FS
- Gas type: customer-specified process gas; high-flow semiconductor gases such as N2, Ar and He
- Operating pressure: max 700 kPaG
- Differential pressure: 100 to 300 kPa; for 101 to 150 SLM, 150 to 300 kPa
- Wetted materials: SUS316L stainless steel, PCTFE seats
- Seals: metal seal with Au gasket
- Valve type: bellows-sealed metal diaphragm valve, normally open or normally closed
- Leak integrity: 1×10⁻¹¹ Pa·m³/s He or better
- Electrical interface: analog 0-5 VDC, RS-485, DeviceNet, EtherCAT
- Power supply: ±15 VDC for the 0-5 VDC analog link
- Heated option: no; standard unit is unheated
- Dimensions: 154 mm high × 192.4 mm wide × 116 mm deep
Environment and Immunity
- Operating temperature: 5°C to 45°C.
- Environmental tolerance: stable control across the rated ambient band.
- Interference resistance: metal body and digital bus options suit busy tool floors.
- Surface finish: EP surface finish supports high-purity lines.
Installation Guide
- Mount the unit with 3/8 UJR or F900 fittings.
- Keep inlet pressure at or below 700 kPaG.
- Provide 100 to 300 kPa differential pressure.
- For 101 to 150 SLM, supply 150 to 300 kPa.
- Allow space for the 154 × 192.4 × 116 mm body.
- Use the specified process gas only.
- Wire the analog or digital link to your controller.
- Check external joints for leaks before first use.
Setup and Maintenance
- The metal diaphragm valve resists wear in clean gas.
- Normally open or closed builds match your fail-safe plan.
- Digital buses speed up setup and checks.
- PCTFE seats are easy to inspect during service.
- The Au gasket seal keeps purity high between services.
- Wide turndown lowers the need for extra units.
Compatibility
- Works with analog 0-5 VDC controls.
- Supports RS-485, DeviceNet and EtherCAT.
- Fits CVD chamber purge and chamber pressure control.
- Serves bulk gas distribution and high-flow semiconductor delivery.
- Matches 3/8 UJR and F900 fitting systems.
Certification
- CE marked for compliance.
- RoHS compliant.
- EP surface finish for high-purity service.
Packing List
- One FCST1200MF mass flow controller.
- One calibration and test report.
- One installation and operation guide.
- One interface wiring reference.
- Protective caps and shipping packaging.
FAQ
Q: What flow can this controller handle?
A: It covers 51 to 150 SLM in N2 equivalent.
Q: Which valve action can I order?
A: You can choose normally open or normally closed.
Q: How much differential pressure does it need?
A: Plan for 100 to 300 kPa. Above 101 SLM, use 150 to 300 kPa.
Q: Does the accuracy hold over the full ambient range?
A: Yes. The ±1% FS figure is guaranteed from 15 to 35°C.
Q: What fittings does it use?
A: It takes 3/8 UJR or F900 fittings.
Q: From experience, what causes flow errors at high rates?
A: Low differential pressure is the common cause. Keep supply pressure steady and stay inside the 150 to 300 kPa band above 101 SLM.
Q: How do I protect purity during service?
A: Use new Au gaskets, keep parts bagged, and run a helium leak check. Target 1×10⁻¹¹ Pa·m³/s He or better.
Q: What should I check before fitting a replacement?
A: Check the body space, the fitting type and the valve action. The 154 × 192.4 × 116 mm body needs room for cabling.
Q: Why does the unit seem slow to settle?
A: Gas line volume and pressure swings slow the loop. Shorten the line run and hold inlet pressure steady within 700 kPaG.
Q: Can I use a different gas than the one ordered?
A: No. Each unit is set for a customer-specified gas. Confirm the gas match before you install it.















There are no reviews yet.