Product details
FCST1030MZF-HT Heated Metal-Sealed MFC by Fujikin
- FCST1030MZF-HT is a heated metal-sealed mass flow controller.
- Built by Fujikin.
- Belongs to the FCST T1000 Series.
- Type: FCS-T1000MZF-HT High Temperature MGMR.
- It heats the flow path to 50-80°C.
- This keeps condensable gases in vapor form.
- No cold spots, no clogging.
- MGMR gives you multi-gas and multi-range control.
- One unit covers many gas setups.
- Stock fewer spare parts.
- A Hastelloy C sensor fights halogen and corrosive gases.
- Long life in etch and CVD tools.
- Remote electronics option moves heat away from control boards.
Why the FCST1030MZF-HT Stands Out
- Heated flow path from 50°C to 80°C.
- Stops condensation of high-vapor-pressure gases.
- Keeps lines clean and stable.
- MGMR multi-gas, multi-range memory.
- One body handles many recipes.
- Fast changeover in software.
- Hastelloy C sensor resists halogen attack.
- Built for chlorine and other reactive gases.
- Metal seal with Au gasket gives tight leak integrity.
- Leak rate ≤1×10⁻¹¹ Pa·m³/s He.
- Remote electronics cuts heat stress on control parts.
Core Technical Data
- Brand: Fujikin
- Model: FCST1030MZF-HT
- Series: FCST T1000 Series
- Type: FCS-T1000MZF-HT High Temperature MGMR
- Full-scale flow range: 3,001 to 30,000 SCCM (N2 equivalent)
- Bin 6-7 covers this band.
- Accuracy: ±1% of set point (25-100%)
- ±0.25% FS (2-25%)
- Repeatability: ±0.2% FS
- Response time: ≤1 second
- Control range: 2-100% FS
Temperature and Environment
- Heated operation: 50-80°C
- Custom calibration temperature on request.
- Ambient range: 50-80°C in heated mode
- Max pressure: 400 kPaG
- Ar service: 500 kPaG
- Leak integrity: ≤1×10⁻¹¹ Pa·m³/s He
- Au gasket metal seal.
- Noise and drift: digital link and PI-style control keep signal steady
Wetted Materials and Seals
- Body: SUS316L stainless steel
- Sensor: Hastelloy C
- Seats: PCTFE
- Seal: Au gasket, metal seal
- These parts suit high-purity and reactive gas.
Gas and Range Flexibility
- Gas type: MGMR multi-gas, multi-range
- Heated path handles condensable gases.
- Hastelloy C sensor handles corrosive gases.
- Change gas or range in software.
- No hardware swap needed.
- Fewer SKUs to stock.
Electrical Interface
- Analog: 0-5 VDC output with ±15 VDC supply
- Also +24 VDC with 0-5 VDC or 4-20 mA
- Digital: RS-485
- Power: ±15 VDC or +24 VDC option
- Remote electronics option keeps heat off the control board
Valve and Size
- Valve type: bellows-sealed metal diaphragm valve
- Order N/O or N/C.
- Bellows seal protects the actuator.
- Dimensions: 125 H × 124 W × 70 D mm
- Small body fits tight gas cabinets.
Install Guide
- Mount the unit on a clean, dry gas line.
- Keep lines short and free of traps.
- Warm the unit to 50-80°C before process gas flows.
- Cold spots cause condensation.
- Keep line pressure at or below 400 kPaG.
- Ar service: 500 kPaG.
- Wire ±15 VDC or +24 VDC power.
- Pick 0-5 VDC, 4-20 mA, or RS-485.
- Fit a fresh Au gasket at each joint.
- Leak-check with He before use.
- Keep the remote electronics away from hot parts.
Setup and Upkeep
- Heat-up is quick and stable.
- Let the unit reach set temperature first.
- MGMR tables change in software.
- No line break needed.
- Zero drift stays low over the year.
- Fewer recalibrations.
- Remote electronics makes board service easy.
- Swap boards without breaking the gas path.
Compatibility
- Fits standard semiconductor gas panels.
- Works in gas cabinets and gas boxes.
- Matches common host networks.
- RS-485, 0-5 VDC, 4-20 mA.
- Pairs with heated line bundles.
- Keeps the whole path warm.
- Check PCTFE seats against your gas list.
Certifications
- CE marked
- RoHS compliant
- EP surface finish for high-purity service
Typical Applications and Equipment
- Heated gas delivery for condensable sources
- Liquefied precursor CVD and etch
- Halogen gas handling
- Diffusion furnaces
- Equipment types
- CVD and PVD tools
- Etch chambers
- Gas cabinets and gas boxes
- Thin-film deposition systems
- Tools with heated lines
Packing List
- One FCST1030MZF-HT mass flow controller
- One calibration certificate
- One quick-start guide
- One Au gasket and fitting kit
- One cable set for your interface
- Remote electronics kit when ordered
- Confirm the final list with your Fujikin distributor.
FAQ
- Why does the unit need heat?
Some gases turn to liquid when they cool. Heat keeps them in vapor form. Flow then stays smooth and repeatable. - Can I pick my own temperature?
Yes. The standard band is 50-80°C. You can ask for a custom calibration temperature that fits your recipe. - What if a cold spot forms downstream?
Wrap the line with heat trace. Keep the whole path warm, not just the MFC body. This prevents liquid drops and clogs. - Field experience: how do I stop condensation after a gas swap?
Warm the new line first. Then open the gas slowly. A fast cold rush often causes droplets and reading errors. - Field experience: why do readings jump in a hot cabinet?
Heat can reach the control board. Use the remote electronics option. Move the board to a cooler spot.