Over 50,000 hot-selling automation module components.

FCST1200F Fujikin High-Flow MFC 200 SLM Rubber Seal

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: FCST1200F
Brands:

Product details

FCST1200F High-Flow Rubber-Seal MFC by Fujikin

The FCST1200F is a high-flow mass flow controller from the FCST T1200 Series. It covers 51 to 200 SLM of N2 equivalent flow. A rubber seal (FKM) and PCTFE seat keep the design cost-effective. Accuracy is ±1% FS in the 15-35°C window. Repeatability is ±0.2% FS. Response time stays at or below 3 seconds. The FCST1200F handles non-corrosive high-flow gases such as N2, Ar, He, and Air. It fits CVD chamber purge, bulk gas distribution, and high-flow semiconductor gas lines. The bellows-sealed diaphragm valve comes in N/O or N/C form. Standard fittings include 3/8 UJR or F900. This unit gives you a practical high-flow option with proven accuracy.

Technical Data

  • Brand: Fujikin
  • Model: FCST1200F
  • Series: FCST T1200 Series (FCS-T1200F High Flow, Rubber Seal)
  • Module type: Mass flow controller (MFC)
  • Full-scale flow range: 51 to 200 SLM (N2 equivalent)
  • Control range (turndown): 2-100% FS
  • Accuracy: ±1% FS (guaranteed from 15-35°C)
  • Repeatability: ±0.2% FS
  • Response time: ≤3 seconds
  • Linearity: Covered by the ±1% FS accuracy spec
  • Resolution and sensitivity: Set by the sensor and full-scale range
  • Operating temperature: 5-45°C
  • Gas type: Customer-specified process gas; high-flow non-corrosive gases (N2, Ar, He, Air, etc.)
  • Operating pressure: Max 700 kPaG; required differential pressure 100-300 kPa
  • Wetted materials: SUS316L stainless steel, PCTFE seats
  • Seals: Rubber (FKM)
  • Valve type: Bellows-sealed diaphragm valve (N/O or N/C)
  • Leak integrity: ≤1×10⁻⁷ Pa·m³/s He (rubber seal)
  • Electrical interface: Analog 0-5 VDC (±15 VDC); 4-20 mA (+24 VDC); digital RS-485, DeviceNet, EtherCAT
  • Power supply: ±15 VDC (0-5 VDC analog); +24 VDC (4-20 mA)
  • Heated option: No (standard unheated version)
  • Fittings: 3/8 UJR or F900
  • Compliance: RoHS compliant; CE

Installation Guide

  • Mount the FCST1200F with the flow arrow matched to real gas direction.
  • Keep inlet pressure at or below 700 kPaG.
  • Provide 100-300 kPa differential pressure for full flow.
  • Use 3/8 UJR or F900 fittings that match your gas panel.
  • Wire the analog or digital interface that fits your tool.
  • Keep ambient temperature between 5°C and 45°C.

Setup and Maintenance Convenience

  • Fast response (≤3 s) shortens purge and switchover steps.
  • The bellows-sealed diaphragm valve resists wear.
  • Simple analog and digital options cut wiring time.
  • FKM seals allow low-cost field service.
  • The compact body fits tight gas panel spaces.
  • Wide 2-100% FS control range covers many recipes.

Compatibility Notes

  • Works with RS-485, DeviceNet, and EtherCAT fieldbus tools.
  • Analog control supports 0-5 VDC and 4-20 mA systems.
  • Suits N2, Ar, He, and Air lines in semiconductor fabs.
  • Pairs with 3/8 UJR and F900 fitting standards.
  • Fits CVD chamber purge and bulk gas distribution skids.

Certification and Compliance

  • RoHS compliant.
  • CE marked.
  • Leak integrity at or below 1×10⁻⁷ Pa·m³/s He.

Packing List

  • One FCST1200F mass flow controller
  • One calibration and test report
  • One user documentation set
  • One fitting kit (3/8 UJR or F900, per order)
  • Protective caps and shipping carton

FAQ

Q: What makes this model a good fit for high flow?

A: It covers 51-200 SLM with a wide 2-100% FS control range. The bellows diaphragm valve stays stable at high rates.

Q: Which gases can I run through it?

A: Use non-corrosive gases such as N2, Ar, He, or Air. Tell us your gas at order time for the right calibration.

Q: How much differential pressure does it need?

A: Plan for 100-300 kPa across the unit. Low DP may limit top-end flow.

Q: My flow drops at high set points. What should I check?

A: Check differential pressure first. Then check the inlet filter for particles.

Q: Does it need heat?

A: No. The standard unit is unheated and works from 5-45°C.

Q: Can I pick N/O or N/C valve action?

A: Yes. Both normally open and normally closed versions are offered.

Q: What fittings come standard?

A: Choose 3/8 UJR or F900 at order. Both fit common gas panels.

Q: Which digital protocols does it support?

A: RS-485, DeviceNet, and EtherCAT are supported alongside analog control.

Specifications

  • BrandAllen-Bradley
  • Part Number22A-B012F104
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “FCST1200F Fujikin High-Flow MFC 200 SLM Rubber Seal”

Your email address will not be published. Required fields are marked *

Back to Top