Product details
Product Description
- The FCST1005L is an analog economy mass flow controller from Fujikin.
- It belongs to the FCST T1000 Series (FCS-T1000L Analog Economy).
- Full-scale range covers 10 SCCM to 5 SLM (N2 equivalent).
- The body uses SUS316L stainless steel with PCTFE seats.
- A bellows-sealed diaphragm valve controls flow in N/O or N/C mode.
- This model keeps wiring simple with a 0-5 VDC analog signal only.
- Its compact 125 × 124 × 77 mm footprint fits dense gas cabinets.
- Typical uses include CVD, PVD, etching, diffusion, and thin-film deposition.
- The design targets high-volume analog control with tight cost control.
Technical Data
- Brand: Fujikin
- Model: FCST1005L
- Series: FCST T1000 Series (FCS-T1000L Analog Economy)
- Full-Scale Flow Range: 10 SCCM to 5 SLM (N2 equivalent)
- Accuracy: ±1% FS (10 SCCM–30 SLM); ±2% FS (31–50 SLM), guaranteed at 15–35°C
- Repeatability: ±0.2% FS
- Response Time: 1 sec or less (10 SCCM–30 SLM); 2 sec or less (31–50 SLM)
- Gas Type: Customer-specified process gas; N2, Ar, He, H2, O2 and standard semiconductor gases
- Operating Pressure: Max 400 kPaG; required differential pressure 50–300 kPa
- Wetted Materials: SUS316L stainless steel, PCTFE seats
- Seals: Rubber (FKM) standard; metal seal option
- Electrical Interface: Analog 0–5 VDC only (±15 VDC supply)
- Heated Option: No (standard unheated version)
- Operating Temperature: 5–50°C
- Control Range / Turndown: 2–100% FS
- Dimensions: 125 (H) × 124 (W) × 77 (D) mm
- Power Supply: ±15 VDC (0–5 VDC analog)
- Valve Type: Bellows-sealed diaphragm valve (N/O or N/C)
- Leak Integrity: 1×10⁻⁷ Pa·m³/s He or less (rubber seal); 1×10⁻¹¹ Pa·m³/s He or less (metal seal option)
- Compliance: RoHS compliant; CE
Measurement Range and Performance
- Measurement range: 10 SCCM to 5 SLM (N2 equivalent).
- Frequency response: 1 sec or less up to 30 SLM; 2 sec or less above that.
- Sensitivity: Repeatability of ±0.2% FS gives a steady reading.
- Linearity: Covered by the ±1% FS or ±2% FS accuracy figure.
- Resolution: Set by the 0–5 VDC analog output and your readout.
- Temperature range: 5°C to 50°C operating.
- Environmental tolerance: 400 kPaG max inlet pressure.
- Anti-interference: Bellows-sealed valve limits drift and contamination.
Installation Guide
- Mount the unit with clear space around the compact body.
- Keep operating temperature between 5°C and 50°C.
- Do not exceed 400 kPaG inlet pressure.
- Set differential pressure between 50 and 300 kPa.
- Feed the ±15 VDC supply to the unit.
- Route the 0–5 VDC signal to your controller.
- Match the gas setting to the ordered process gas.
Setup and Maintenance Convenience
- Analog-only wiring cuts setup time and panel cost.
- The small footprint eases gas cabinet builds.
- The bellows-sealed diaphragm valve resists particle buildup.
- FKM seals suit most standard semiconductor gases.
- The metal seal option tightens leak performance when needed.
- Repeatability of ±0.2% FS keeps tuning work low.
Compatibility Notes
- Works with 0–5 VDC analog controllers only.
- Requires a ±15 VDC supply.
- Handles N2, Ar, He, H2, O2 and standard semiconductor gases.
- Fits CVD, PVD, etch, diffusion, and gas cabinet lines.
- Choose the metal seal option for tighter leak specs.
- The N/O or N/C valve choice fits your fail-safe scheme.
Certification Information
- CE certification is confirmed.
- The unit meets RoHS compliance.
- Rubber seal leak rate is 1×10⁻⁷ Pa·m³/s He or better.
- Metal seal option reaches 1×10⁻¹¹ Pa·m³/s He or better.
Packing List
- One FCST1005L mass flow controller.
- One user document set.
- One calibration record.
- One connector kit as ordered.
FAQ
- Q: Can I use a digital fieldbus with this model?
- A: No. This unit offers a 0–5 VDC analog interface only. Pick another series member if you need digital control.
- Q: Which seal should I order?
- A: Standard FKM rubber seals fit most semiconductor gases. Choose the metal seal option when your leak spec is very tight.
- Q: Why does accuracy change above 30 SLM?
- A: The spec relaxes to ±2% FS from 31 to 50 SLM. Accuracy is guaranteed only at 15–35°C, so keep the room in that band.
- Q: What is the most common field mistake with this controller?
- A: In our experience, users underfeed the differential pressure. Below 50 kPa the valve cannot hold setpoint at high flow. Check DP at full demand.
- Q: Does the valve fail open or closed?
- A: You choose N/O or N/C at order. Match it to your gas cabinet fail-safe logic.
- Q: How much warm-up does it need?
- A: The datasheet does not state a warm-up time. Most sites allow about 30 minutes for stable thermal readings.
- Q: Can I swap gases in the field?
- A: No. The factory sets the gas at order. Order the process gas you plan to run.