Product details
Product Overview
FC-R7800 is a metal-sealed analog mass flow controller from AERA. It handles inert and corrosive gases with high accuracy. The all-metal design protects gas purity. It suits demanding semiconductor processes.
- Full-scale range: 10 sccm to 5 slm. One platform covers low and mid flows.
- Accuracy: within +/-1% of full scale. Stable results across the control range.
- Response: under 1 second settling time to +/-2% of full scale.
- Wetted parts: 316L and 316 stainless steel, PTFE, magnetic stainless. Metal seals keep leaks minimal.
- Leak integrity: 1 x 10^-10 atm-cc/sec (He). This protects yield and safety.
Core Technical Data
- Brand: AERA
- Model: FC-R7800
- Series: FC-R7800 Series (Analog, metal-sealed)
- Module type: Analog mass flow controller (MFC)
- Flow range: 10 sccm to 5 slm full scale
- Accuracy: +/-1% of full scale or better
- Repeatability: +/-0.2% of full scale or better
- Linearity: +/-0.5% of full scale or better
- Response time: under 1 second flow-settling to +/-2% of full scale
- Control range: 2% to 100% of full scale (turndown 50:1)
- Zero stability: under 0.5% of full scale per year
- Gas types: all inert and corrosive gases
- Operating pressure: differential 7 to 40 psiD; normal 70 psig; max inlet 140 psig
- Wetted materials: 316L and 316 stainless steel, PTFE, magnetic stainless
- Seals: metal (316L)
- Valve: solenoid, normally-open or normally-closed
- Electrical interface: analog 0 to 5 VDC command and output; Aera 9-pin D connector
- Power: +15 VDC at 25 mA; -15 VDC at 180 mA; 3.1 W max
- Heated option: no (standard unheated version)
- Dimensions: 132 x 28.6 x 183.8 mm (port-to-port 183.8 mm with 1/4 in VCR)
- Weight: 1.0 kg (2.2 lb)
Temperature Range and Environment
- Operating temperature: 5 to 45 degrees C (41 to 113 degrees F)
- Pressure tolerance: max inlet 140 psig; normal 70 psig
- Leak integrity: 1 x 10^-10 atm-cc/sec (He) max; 1 x 10^-11 Pa-m3/sec (He) max
- Compliance: RoHS
Installation Guide
- Mount the unit in any orientation. Keep the port-to-port length of 183.8 mm in mind for 1/4 in VCR fittings.
- Use clean, dry gas lines. Purge lines before first use.
- Keep differential pressure between 7 and 40 psiD for stable control.
- Do not exceed 140 psig inlet pressure.
- Connect the 9-pin D connector to the Aera analog interface.
- Provide +15 VDC and -15 VDC within +/-2%. Check current draw before power-up.
- Keep ambient temperature within 5 to 45 degrees C.
- Match the valve type to your fail-safe needs: normally-open or normally-closed.
Setup and Maintenance Ease
- Standard connectors and dimensions make drop-in replacement simple.
- Analog 0 to 5 VDC command and output need no digital setup.
- Zero stability under 0.5% per year cuts recalibration frequency.
- Metal seals resist corrosion and reduce downtime.
- No heater means fewer parts and simpler service.
Compatibility Notes
- Works with inert and corrosive gas lines.
- Fits systems that use the Aera 9-pin D analog interface.
- Replaces units with the same 1/4 in VCR port-to-port length of 183.8 mm.
- Suits semiconductor tools: CVD, PVD, etch, diffusion, ion implantation and sputtering.
Certification and Compliance
- RoHS compliant
- High leak integrity verified to 1 x 10^-10 atm-cc/sec (He)
- Built with 316L and 316 stainless steel wetted parts
Packing List
- 1 x AERA FC-R7800 analog mass flow controller
- 1 x 9-pin D connector
- 1 x calibration certificate
- 1 x user manual
FAQ
Q: Can I use one FC-R7800 for both low and high flows?
A: Yes. The full-scale range covers 10 sccm to 5 slm. Pick the unit closest to your working flow.
Q: How fast does the flow settle after a set point change?
A: It settles within +/-2% of full scale in under one second.
Q: Does it handle corrosive gases?
A: Yes. Metal seals and 316L stainless steel wetted parts resist corrosive media.
Q: What pressure do I need at the inlet?
A: Keep differential pressure at 7 to 40 psiD. Do not exceed 140 psig inlet.
Q: Is a heated version available?
A: This standard unit is unheated. Check AERA options if you need heating.
Q: From experience, what causes drift?
A: Dirty gas lines and unstable supply pressure are common causes. Purge lines and regulate pressure first.
Q: My old MFC failed. Can I swap it directly?
A: Often yes. Match the 1/4 in VCR port-to-port length of 183.8 mm and the 9-pin D interface.
Q: How often should I recalibrate?
A: Zero stability is under 0.5% per year. Many users check calibration once a year.
Current lifecycle status: active. Official product pages verified as of 2026-11.













There are no reviews yet.