FC-772 AERA Mass Flow Controller | FC-7700 Series 35-150 slm

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: FC-772
Brands:

Product details

Product Overview

FC-772 is a high-flow analog mass flow controller from the AERA FC-7700 Series. It handles 35 slm to 150 slm full-scale flow. The 3-digit elastomer-sealed design suits high-flow, non-corrosive gas lines. A larger body and a 20-pin Aera card-edge connector make integration simple. Typical users are semiconductor fabs running CVD, PVD, etch, diffusion, ion implantation, and sputtering.

  • Brand: AERA
  • Model: FC-772
  • Series: FC-7700 Series (3-digit analog, elastomer-sealed)
  • Module type: Analog mass flow controller

Technical Data

  • Brand: AERA
  • Model: FC-772
  • Full-scale flow range: 35 slm to 150 slm
  • Accuracy: within plus or minus 2% of full scale
  • Repeatability: within plus or minus 0.2% of full scale
  • Response time: under 3 sec to within plus or minus 2% of full scale between set points
  • Linearity: within plus or minus 1% of full scale
  • Resolution and turndown: control range 2% to 100% of full scale
  • Zero stability: under 0.5% of full-scale flow over one year
  • Gas type: all inert gases, such as N2, O2, Ar, and He
  • Operating pressure: differential 21 to 40 psiD; normal 70 psig; maximum inlet 140 psig
  • Wetted materials: 316(L) stainless steel, PTFE, magnetic stainless
  • Seals: elastomer, fluoroelastomer or chloroprene rubber
  • Valve type: solenoid, normally-open or normally-closed
  • Leak integrity: 1 x 10^-6 atm-cc/sec (He) max
  • Electrical interface: analog 0 to 5 VDC command and output; Aera 20-pin card-edge connector
  • Power supply: +15 VDC plus or minus 2% at 25 mA; -15 VDC plus or minus 2% at 200 mA; 3.5 W max
  • Heated option: no, standard unheated version
  • Temperature range: 5 to 45 degrees C (41 to 113 degrees F)
  • Environmental tolerance: indoor, clean, non-corrosive gas service
  • Interference resistance: shielded analog signal path with a card-edge connector
  • Dimensions (H x W x D): 149 x 38 x 183.8 mm
  • Weight: 2.27 kg (5.0 lb)

Installation Guide

  • Mount the unit on a stable, level surface near the gas line.
  • Keep inlet pressure at or below 140 psig.
  • Hold differential pressure between 21 and 40 psiD.
  • Flush the line before you connect the controller.
  • Use clean, dry inert gas only.
  • Plug the 20-pin card-edge connector into the Aera slot.
  • Check +15 VDC and -15 VDC supply polarity before power-on.
  • Keep cables away from high-current wiring to cut noise.
  • Confirm 0 to 5 VDC command and output levels at start-up.
  • Run a zero check with no flow before you set the process point.

Setup and Maintenance Ease

  • Analog 0 to 5 VDC interface needs no digital setup tool.
  • The 20-pin connector allows fast swap in the field.
  • Zero drift stays under 0.5% of full scale per year.
  • Fewer recalibration trips mean less downtime.
  • The unheated body keeps service steps simple.
  • Standard elastomer seals are easy to source.

Compatibility Notes

  • Works with Aera controllers that use the 20-pin card-edge interface.
  • Fits gas panels built for the FC-7700 Series footprint.
  • Suited to inert gas lines: N2, O2, Ar, and He.
  • Not for corrosive or reactive gases.
  • Pairs with 0 to 5 VDC analog command sources.
  • Needs a dual +15 VDC and -15 VDC supply.

Certification and Compliance

  • RoHS: compliant
  • Leak integrity: 1 x 10^-6 atm-cc/sec (He) max
  • Lifecycle status: current, official product pages active as of 2026-11

Packing List

  • 1 x AERA FC-772 mass flow controller
  • 1 x protective shipping carton
  • 1 x documentation set
  • Note: confirm cable and accessory items with your order.

FAQ

Q: Which gases can I run through this controller?

A: Use inert gases only, such as N2, O2, Ar, and He. Corrosive gases will damage the wetted parts.

Q: How fast does the unit reach a new set point?

A: It settles within plus or minus 2% of full scale in under 3 seconds. Most process steps see a smooth ramp.

Q: What supply does the board need?

A: It needs +15 VDC at 25 mA and -15 VDC at 200 mA. Total draw stays at 3.5 W or less.

Q: Can I mount it in any position?

A: Keep the body level and stable. This protects the sensor and keeps zero drift low.

Q: How often should I check zero?

A: Zero drift stays under 0.5% of full scale per year. Many fabs check zero at each tool qual.

Q: Why does my flow reading drift after a year?

A: Small zero shifts are normal over time. Re-zero the unit and check inlet pressure first. If drift continues, inspect the seals.

Q: The valve will not open. What should I check?

A: Check both 15 VDC rails and the 20-pin connector seat. Also confirm the command signal reaches 0 to 5 VDC.

Q: Can I replace an older FC-7700 unit with this model?

A: Yes, if the panel uses the same 20-pin card-edge interface and footprint. Verify pressure and flow range first.

Specifications

  • BrandAllen-Bradley
  • Part Number22A-B012F104
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “FC-772 AERA Mass Flow Controller | FC-7700 Series 35-150 slm”