Product details
E82ZAFSC010 Lenze 8200 vector I/O Module – Spring-Clamp PT Card
E82ZAFSC010 is a plug-in standard I/O PT function module from the Lenze 8200 vector family. It fits the FIF slot on 8200 vector and 8200 motec drives. The card adds analog and digital signals to the drive. A pluggable spring-clamp strip makes wiring fast. No tools are needed for most connections.
This module is a legacy part. Lenze still lists it on the official previous-products page. It is a simple, low-cost way to add I/O to running machines. No firmware or bus setup is needed. The host drive powers the card through its internal bus.
Key Highlights
- Fast wiring: Spring-clamp strip, no screwdriver needed.
- Mixed I/O: Analog in and out plus digital in and out.
- Relay output: One relay contact for simple switching.
- Frequency input: One digital input can read 0 to 10 kHz.
- Plug and play: Slots into the FIF socket on the drive.
Technical Data
- Brand: Lenze
- Model: E82ZAFSC010
- Series: 8200 vector
- Type: Standard I/O PT function module
- Slot: FIF slot, 8200 vector and 8200 motec
I/O Layout
- Analog input: 1 channel, 0 to ±10 V or 0/4 to 20 mA, 10-bit
- Analog output: 1 channel, 0 to 10 V, max 2 mA
- Digital inputs: 4 channels, PLC level
- Frequency input: 1 optional, 0 to 10 kHz
- Digital output: 1 channel
- Relay output: 1 channel
Connection Details
- Terminal type: Pluggable spring-clamp strip
- Port: X3 plug-in terminal strip
- Wire size: 1.5 mm² (AWG 16), rigid or flexible, no ferrules
- Front protrusion: About 13 mm from the inverter face
Electrical Notes
- Supply: From host drive internal bus, no separate feed
- Power draw: Not applicable, card takes host power
- Insulation to PE: 50 V AC
- Protocols: None, this is an I/O card only
- Fieldbus: Use a separate bus module if needed
Environment
- Operating temperature: -20 to +60 °C
- Storage temperature: -25 to +60 °C
- Humidity: Average 85 % RH, no condensation
- Climate class: 3K3 per EN 50178
- Housing size and weight: Not published by Lenze
Installation Steps
- Power off the drive and wait for the DC link to discharge.
- Open the FIF slot cover on the inverter front.
- Slide the E82ZAFSC010 card into the slot.
- Press until the connector seats fully.
- Plug in the X3 spring-clamp strip.
- Strip wires to length and push them in.
- Check each wire with a light pull.
- Power up and test each I/O channel.
Setup and Service
- No address or firmware setup is needed.
- Set analog ranges in the drive parameters.
- Label each wire for future service.
- Check terminal grip at routine maintenance.
- Clean dust from the card edge contacts.
- Swap the card if a channel fails.
Compatibility
- Fits 8200 vector drives with an FIF slot.
- Fits 8200 motec drives with an FIF slot.
- Uses host drive power, no external supply.
- Does not add fieldbus features.
- Lenze names no direct successor part.
- Check the drive label before you order.
Approvals and Standards
- Climatic class 3K3 per EN 50178.
- Insulation rating 50 V AC to PE.
- Final machine EMC depends on the panel build.
- No standalone certificate is published for this card.
- Follow local electrical rules for your site.
Packing List and Warranty
- One E82ZAFSC010 I/O module
- One X3 spring-clamp terminal strip
- Factory packing and labels
- Warranty: 12 months
- Dispatch: 12 to 24 hours
- Couriers: FedEx, UPS, DHL
- Tracking sent after dispatch
Expert Review
The E82ZAFSC010 solves a narrow problem well. It adds mixed I/O to an old 8200 vector drive without a bus. The spring clamps save time on small panels. The 10-bit analog input is fine for speed and torque setpoints. Do not expect high precision. Buyers should treat it as a service part. Confirm the drive slot and the existing card type first. For maintenance teams, this card keeps old machines running at low cost.
Manager’s Insight
This card sells to service engineers, not to new machine builders. Most orders come from plants that still run 8200 vector drives. Keep two or three units on the shelf. Ask for a photo of the drive label at order review. That one step prevents most returns. Offer a wiring note with each sale. Fast dispatch matters more than price here. Send fitment questions to sales@powergearx.com or +86 18030005825.
Best-Fit Equipment and Applications
- 8200 vector drives with an open FIF slot
- 8200 motec drives in compact machines
- Speed setpoint from a 0 to 10 V signal
- Simple start and stop from digital inputs
- Pulse feedback from a small encoder
- Relay control of a brake or lamp
- Retrofit and spare-part jobs
FAQ
- Which slot does this card use?
It goes in the FIF slot on 8200 vector and 8200 motec drives. - Do I need a separate power supply?
No. The host drive feeds the card through its internal bus. - What wire size fits the clamps?
Up to 1.5 mm² (AWG 16), rigid or flexible, without ferrules. - Does it support a fieldbus?
No. Use a separate bus module for that. - Experience tip: why do channels read wrong?
Most faults come from loose wires. Pull-test each wire after you install it. - Buying tip: how do I avoid a wrong order?
Send your drive label photo before you buy. We check the slot and card type for you. - Buying tip: what is the warranty and lead time?
12 months cover. Ships in 12 to 24 hours by FedEx, UPS, or DHL.
Buying Guide
- Read the drive label to confirm the FIF slot.
- List the signals you need before you order.
- Keep one spare card for each critical machine.
- Ask for a fitment check if you are unsure.
- Plan wire labels before you install.
- Order early to avoid line stops.
Contact
Email: sales@powergearx.com
WhatsApp: +86 18030005825
Copyright © 2026 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/















There are no reviews yet.