Over 50,000 hot-selling automation module components.

E82ZAFSC001 Lenze Coated Function Card for 8200 vector Drives

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: E82ZAFSC001

Product details

E82ZAFSC001 Lenze 8200 vector I/O Function Module, Coated Design

E82ZAFSC001 is a standard I/O function module from the Lenze 8200 vector series. It uses a conformal coated PCB for tough industrial sites. The module plugs into the FIF slot of 8200 vector and 8200 motec drives. It adds analog and digital points to the drive. No extra power supply is needed. The host drive feeds it through the internal bus.

Quick Highlights

  • Coated board. Better protection against dust, moisture and fumes.
  • Mixed I/O in one card. One analog in, one analog out, five digital in, one digital out.
  • Simple wiring. Terminal strip X3 takes wires up to 1.5 mm².
  • Wide temperature window. Runs from -20 to +60 °C.
  • Plug and play. Slots straight into the drive. No settings on the card.
  • Proven legacy part. Still listed on the official Lenze previous products page.

Technical Data

  • Brand: Lenze
  • Model: E82ZAFSC001
  • Series: 8200 vector
  • Type: Standard I/O function module, coated version
  • Slot: FIF slot on 8200 vector and 8200 motec drives
  • Analog input: 1 channel
  • Analog output: 1 channel
  • Digital inputs: 5 channels
  • Digital output: 1 channel
  • PCB finish: Conformal coating for industrial use
  • Connection: Plug-in terminal strip X3, wire size up to 1.5 mm²
  • Built-in ports: Plug-in terminal strip X3 only
  • Protocols: None. Fieldbus needs a separate bus function module.
  • Communication expansion: Not applicable. The host drive internal bus powers the card.
  • Supply voltage: Not applicable. It is an option card.
  • Power consumption: Not applicable. The host drive supplies it.
  • Operating temperature: -20 to +60 °C
  • Storage temperature: -25 to +60 °C
  • Relative humidity: 85 % RH average, no condensation (class 3K3 per EN 50178)
  • Insulation voltage to PE: 50 V AC
  • Dimensions: Not published by the manufacturer
  • Weight: Not published by the manufacturer
  • Lifecycle: Legacy. Official Lenze previous products page is active. Newer drive lines replace it.

Signal Path at a Glance

  • Drive FIF slot
    • E82ZAFSC001 card
      • Analog in x1
      • Analog out x1
      • Digital in x5
      • Digital out x1
      • Terminal strip X3
        • Wire up to 1.5 mm²
        • Push-in connection
    • Host drive internal bus
      • No external supply
      • No setup jumpers

Mounting Guide

  • Power down the drive before you open the FIF slot cover.
  • Slide the card into the FIF slot until it clicks.
  • Tighten the fixing screw by hand. Do not overtighten.
  • Wire signals to terminal strip X3. Keep runs short.
  • Use shielded cable for analog lines. Ground the shield at one end.
  • Keep digital and analog wires apart to cut noise.
  • Check the terminal torque and wire size (max 1.5 mm²) before power up.

Setup and Care

  • Set signal type and scaling in the drive parameters. The card has no settings.
  • Test each channel with a meter before you run the machine.
  • The coated board resists dust and moisture. Still keep the cabinet closed.
  • No regular service parts. Check terminal screws at each shutdown.
  • Replace the card if a channel fails. Do not repair the coating in the field.

Compatibility Notes

  • Fits 8200 vector drives with a free FIF slot.
  • Fits 8200 motec drives with a free FIF slot.
  • Needs a separate bus function module for fieldbus links.
  • Not a stand-alone unit. It always runs inside a host drive.
  • Newer Lenze drive lines may need a different card. Check your drive label first.

Approvals and Standards

  • Climatic class 3K3 per EN 50178.
  • Insulation voltage to PE: 50 V AC.
  • Data taken from official Lenze catalogue pages (verified 2026-10).
  • Ask our team for the full certificate list before you buy.

Box Contents

  • 1 x E82ZAFSC001 function module
  • 1 x terminal strip X3
  • 1 x quick start sheet
  • Original factory packaging

Warranty and Delivery

  • 12-month warranty on every card.
  • Parcels leave our warehouse in 12 to 24 hours.
  • Shipping by FedEx, UPS, DHL.
  • Tracking number sent on dispatch day.
  • Need a quote? Write to sales@powergearx.com or chat on WhatsApp +86 18030005825.

Expert Review

The E82ZAFSC001 is a smart fix for old 8200 vector drives that need more I/O. The coated board adds real value in dusty or damp plants. Wiring is easy thanks to the X3 strip and 1.5 mm² range. The mix of analog and digital points covers most retrofit jobs. One limit: it is a legacy part. Stock is finite. Buyers who run 8200 drives should keep a spare on hand. For new builds, look at current Lenze drive lines instead.

Manager’s Insight

This card sells to one clear group: plants still running 8200 vector and 8200 motec drives. Demand is small but steady. Orders often come as urgent repair buys. Keep two or three units on the shelf. Pair them with bus function modules in your stock plan. Our 12 to 24 hour dispatch turns repair calls into quick wins. Push the coated design in your listing. It is the main reason buyers pick this version over the plain card.

Best Fit Equipment and Scenarios

  • 8200 vector drives that need extra analog signals.
  • 8200 motec drives in conveyor and pump skids.
  • Dusty or humid plants where a coated board helps.
  • Retrofit jobs on legacy Lenze drive systems.
  • Machines that need a few digital inputs for switches and limits.
  • Spare parts stock for maintenance teams.

FAQ

  • Q: Can this card work on its own?
    A: No. It needs an 8200 vector or 8200 motec drive.
  • Q: What does the coating protect against?
    A: Dust, moisture and mild fumes. It does not make the card waterproof.
  • Q: How do I set up the analog channels?
    A: Use the drive parameters. The card has no switches.
  • Q: Why buy this instead of a newer drive?
    A: It keeps an existing machine running. That is often cheaper than a full swap.
  • Q: What should I check before ordering?
    A: Confirm your drive model, a free FIF slot and the signal types you need.
  • Q: Is a spare worth the cost?
    A: Yes, if the line must not stop. Legacy parts get harder to find each year.
  • Q: How fast do you ship?
    A: In 12 to 24 hours by FedEx, UPS or DHL, with a 12-month warranty.
  • Q: Who can help me pick the right card?
    A: Email sales@powergearx.com or use WhatsApp. Send your drive label photo.

Buying Guide

  • Find the drive model on the nameplate first.
  • Check that the FIF slot is free.
  • List the signals you need: analog in, analog out, digital in, digital out.
  • Pick the coated card for harsh air. It costs little more and lasts longer.
  • Add a bus function module if you need fieldbus.
  • Order a spare for critical lines. Supply of legacy parts will shrink.

Talk to us: sales@powergearx.com or +86 18030005825.

Copyright © 2026 Powergear X Automation Limited. All rights reserved.

Original Source: https://www.powergearx.com/

Specifications

  • BrandLenze
  • Part NumberE82ZAFSC001
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “E82ZAFSC001 Lenze Coated Function Card for 8200 vector Drives”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart