E82ZAFAC001 Coated I/O Module for Lenze 8200 vector
The E82ZAFAC001 adds flexible I/O to Lenze 8200 vector and 8200 motec drives. It fits the FIF slot. A conformal coating protects the board in tough plant air. You get analog, digital and frequency signals in one small module. It is a proven workhorse for drive retrofit and machine building.
Why Teams Pick This Module
- Coated board. The coated PCB resists dust, damp and fumes.
- Rich I/O set. 2 analog in, 2 analog out, 7 digital in, 2 digital out, 1 frequency out.
- Fast wiring. Terminal strip X3 takes wires up to 1.5 mm².
- No extra supply. The host drive powers it through the internal bus.
- Clear upgrade path. A legacy part that keeps old lines running.
Technical Data
- Brand: Lenze
- Model: E82ZAFAC001
- Series: 8200 vector
- Type: Application I/O function module, coated design
- Slot: FIF slot for 8200 vector and 8200 motec
- Analog inputs: 2
- Analog outputs: 2
- Digital inputs: 7
- Digital outputs: 2
- Frequency output: 1
- Connection: Plug-in terminal strip X3, wires up to 1.5 mm²
- Protocols: None. This is an I/O module. Fieldbus needs a separate bus module.
- Supply voltage: Not applicable. Powered by the host drive internal bus.
- Operating temperature: -20 °C to +60 °C
- Storage temperature: -25 °C to +60 °C
- Humidity: Average 85 % RH, no condensation, class 3K3 per EN 50178
- Insulation voltage: 50 V AC to reference earth/PE
- Dimensions: Not published by the maker
- Weight: Not published by the maker
- Lifecycle: Legacy. Listed on the official Lenze previous products page as of 2026-10.
Order Code Tree
- E82ZAFAC001
- E82 — Lenze 8200 drive family
- ZAF — application function module
- AC — analog and digital I/O set, coated board
- 001 — variant index
- AC — analog and digital I/O set, coated board
- ZAF — application function module
- E82 — Lenze 8200 drive family
- The coated design marks the module for harsh rooms.
Install Steps
- Switch off the drive and wait for the DC link to drop.
- Slide the module into the FIF slot.
- Wire signals to terminal strip X3. Keep wires at or under 1.5 mm².
- Shield analog cables and earth the shield at one end.
- Power on and check each channel in the drive menu.
Setup and Service Ease
- Plug-in strip X3 makes wiring and swaps quick.
- No battery and no moving parts inside.
- Check terminal torque at each service visit.
- Keep the FIF slot dry and dust free.
- The coating cuts failures in humid or dirty air.
Compatibility Notes
- Fits Lenze 8200 vector drives with a free FIF slot.
- Fits Lenze 8200 motec drives with a free FIF slot.
- Carries I/O only. Add a bus module for fieldbus links.
- This is a legacy part. Check slot type before you buy.
Standards and Approvals
- Climatic class 3K3 per EN 50178.
- Insulation 50 V AC to reference earth/PE.
- Built for industrial cabinets and plant rooms.
In the Box and Terms
- 1 x E82ZAFAC001 coated I/O module
- 1 x terminal strip X3
- 12-month warranty on the module
- Dispatch in 12 to 24 hours after order confirmation
- Shipping by FedEx, UPS and DHL
Manager’s Insight
- Many 8200 lines still run well. This module keeps them alive.
- One module covers analog and digital needs. That saves panel space.
- Stock two spares per site. Old parts get hard to find.
- Check the FIF slot first. Wrong slot means a wasted order.
Expert Review
- The I/O count is strong for its size. Seven digital inputs help a lot.
- The coated board is the real win in food, wood and metal shops.
- Wiring is simple. The plug-in strip saves time on swaps.
- Limits: no fieldbus on board. Add a bus module for networks.
- No published size or weight. Plan space by the drive, not the card.
Best Fit Devices and Jobs
- Lenze 8200 vector and 8200 motec drives.
- Conveyors, mixers and fans with extra sensors.
- Retrofit jobs that keep existing 8200 drives.
- Machines that need more digital inputs fast.
- Dusty, damp or fume-heavy plant rooms.
FAQ
- Is this module a fieldbus card?
- No. It gives I/O only. You need a separate bus module for PROFIBUS or other networks.
- Which drives take this card?
- Lenze 8200 vector and 8200 motec drives with a free FIF slot.
- Do I need to wire a power supply?
- No. The drive feeds the card through its internal bus.
- What wire size fits the terminals?
- Up to 1.5 mm² on the plug-in strip X3.
- Is the board protected against harsh air?
- Yes. A conformal coating shields the PCB in industrial rooms.
- Experience tip: one analog input reads wrong. Where do I look?
- Check the shield and the signal ground first. Most faults sit there.
- Experience tip: is this part still made?
- It is listed as legacy. Buy spares early. Supply gets thin over time.
- Buying tip: how do I confirm the slot?
- Check the drive label for the FIF slot. Send us a photo if unsure.
- Buying tip: what backup should I hold?
- Keep one spare card per line. Downtime costs more than the card.
- What warranty and shipping do you offer?
- 12-month warranty. Ships in 12 to 24 hours by FedEx, UPS or DHL.
Buying Guide
- Match the card to your drive model and FIF slot.
- Count your signals before you order. Check 2 analog in and 7 digital in.
- Pick the coated card for dusty or wet rooms.
- Add a bus module if your machine uses a network.
- Order a spare. Legacy stock shrinks each year.
Contact Us
- Email: sales@powergearx.com
- Phone / WhatsApp: +86 18030005825
- Send your drive label for a fast fit check.
Copyright © 2026 Powergear X Automation Limited. All rights reserved.