E82EV552-4C Lenze 8200 Vector Frequency Inverter for 5.5 kW Motors
The E82EV552-4C is a panel-mounted frequency inverter from the Lenze 8200 vector series. It drives a 5.5 kW four-pole asynchronous motor. Moreover, it delivers 13.0 A rated output at 8 kHz. In addition, it supports V/f control, vector control and sensorless torque control. However, this unit is a legacy product. Lenze offers a migration path to the i950 drive. Nevertheless, no drop-in same-order-code replacement exists.
Key Technical Data
- Brand: Lenze
- Model: E82EV552-4C
- Series: 8200 vector
- Product type: Panel-mounted frequency inverter, E design
- Rated motor power: 5.5 kW typical, four-pole three-phase asynchronous motor
- Rated output current: 13.0 A at 8 kHz switching frequency
- Max output current: 19.5 A for 60 s, periodic load change cycle
- Overload: 1.8 x rated torque for 60 s when motor and controller power match
- Motor control: V/f linear and quadratic, vector control, sensorless torque control
- Switching frequency: 2 / 4 / 8 / 16 kHz, noise-optimised setting
- Max output frequency: 0 to 650 Hz
- Supply voltage: 3/PE 320 to 550 V AC, 45 to 65 Hz; alternative DC 450 to 775 V DC
- Power loss: 230 W at rated current and 8 kHz
- Operating temperature: -10 to +55 °C, derated 2.5% per °C above +40 °C
- Storage temperature: -25 to +60 °C
- Relative humidity: average 85% RH, no condensation, climatic class 3K3 per EN 50178
- Protection rating: IP20 per EN 60529; IP41 with push-through thermally separated mounting
- Dimensions H x W x D: 240 x 125 x 140 mm
- Weight: 3.6 kg
Communication and I/O
- Built-in terminals: X3 control terminals with digital inputs, analog input/output and relay output K1
- Onboard fieldbus: None. No integrated fieldbus or Ethernet protocol.
- Expansion: Plug-in I/O and fieldbus option modules, such as E82ZAFSC010 Standard I/O and E82ZAFAC010 Application I/O
Installation Guide
- Mount the unit vertically on a panel. Keep clearance for airflow.
- Use the push-through mounting option for IP41 protection and thermal separation.
- Connect supply power to the 3/PE AC terminals. Check voltage range first.
- Wire motor and control cables to the X3 terminals.
- Set the switching frequency to match noise and load needs.
- Derate output above +40 °C ambient temperature.
Commissioning and Maintenance
- Set motor data in the drive parameters before first start.
- Choose V/f or vector mode for the application.
- Check overload behaviour at 1.8 x rated torque for 60 s.
- Keep the heatsink clean and free of dust.
- Check terminal screws and cable glands at regular service intervals.
Compatibility Notes
- Suits 5.5 kW four-pole three-phase asynchronous motors.
- Works with Lenze plug-in I/O and fieldbus option modules.
- No drop-in replacement by order code. Plan migration to the i950 drive.
- Lenze confirms i950 emulates 8200 vector behaviour via i950 PROFIBUS module and L_ICIP library.
- Migration references cover 8200 vector, 9300, 8400 and 9400 families.
Certification and Compliance
- Protection rating IP20 per EN 60529; IP41 with push-through mounting.
- Climatic class 3K3 per EN 50178 for humidity resistance.
- Official Lenze previous-products page is active for the 8200 vector series.
- Audit status: OFFICIAL_VERIFIED.
Expert Review
The E82EV552-4C is a proven drive for legacy machines. Its 13.0 A rating and 1.8 x overload fit many 5.5 kW motor tasks. Vector and sensorless torque modes give good control without an encoder. However, the lack of onboard fieldbus is a limit. Therefore, buyers should plan an option module or a migration path. In short, stock and support are the main risks for this legacy unit.
Manager’s Insight
This model is best for maintenance and spare-parts use. It keeps older Lenze 8200 vector machines running. However, it is not a future-proof platform. For new builds, compare the i950 migration route first. For urgent repairs, confirm the exact option module and terminal setup before ordering.
Best Fit Equipment and Applications
- Conveyors and material handling lines
- Pumps and fans with variable speed needs
- Packaging and woodworking machines
- Textile and printing equipment
- Legacy machines using Lenze 8200 vector drives
- Spare-parts and retrofit projects
Packing List
- 1 x E82EV552-4C frequency inverter
- 1 x installation and quick-start documentation
- Protective packaging
- Option modules sold separately unless stated
Warranty and Shipping
- Warranty: 12 months.
- Dispatch: 12 to 24 hours after order confirmation.
- Couriers: FedEx, UPS and DHL.
- Contact: sales@powergearx.com or +86 18030005825 for stock and lead-time checks.
FAQ
Q: Is the E82EV552-4C still available?
A: It is a legacy Lenze model. Therefore, availability depends on stock. Check with the sales team before ordering.
Q: Can I replace it with an i950 directly?
A: No. Lenze confirms no drop-in same-order-code replacement. However, the i950 can emulate 8200 vector behaviour with the right module and library.
Q: Does it have a built-in fieldbus?
A: No. It has X3 control terminals only. Add a plug-in fieldbus option module for network control.
Q: What motor does it drive?
A: A 5.5 kW four-pole three-phase asynchronous motor is the typical match.
Q: How do I handle high ambient heat?
A: Derate 2.5% per °C above +40 °C. Also, keep airflow clear around the unit.
Q: What is the overload capacity?
A: 1.8 x rated torque for 60 s when motor and controller power match.
Q: Can I use it with an encoder?
A: The unit supports sensorless torque control. Still, check the option modules for encoder feedback needs.
Q: What is the lead time?
A: Orders usually ship in 12 to 24 hours via FedEx, UPS or DHL.
Q: What warranty do you offer?
A: 12 months from delivery.
Q: Which option module fits standard I/O needs?
A: The E82ZAFSC010 Standard I/O module is a common choice. Before purchase, confirm the terminal plan.
Q: How do I pick between V/f and vector mode?
A: Use V/f for simple pumps and fans. For higher starting torque and better speed hold, use vector or sensorless torque control.
Buying Guide
- First, confirm the motor power and rated current. Match 5.5 kW and 13.0 A.
- Next, check the supply voltage: 320 to 550 V AC three-phase.
- Then, decide if you need a fieldbus option module before ordering.
- For new machines, compare the i950 migration path.
- For repairs, order the exact model and check option module fit.
- Finally, ask for stock confirmation and dispatch time before payment.
Contact sales@powergearx.com or +86 18030005825 for model checks, option modules and shipping quotes.
Copyright © 2026 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/
















There are no reviews yet.