E82EV1534B201 Lenze 8200 Vector Frequency Inverter – 15 kW Precision Drive

The E82EV1534B201 is a built-in vector-controlled inverter from the Lenze 8200 vector series. It delivers 15.0 kW for 4-pole asynchronous motors in the 400 V class. This unit suits demanding industrial motion tasks. It offers strong overload capacity and flexible communication. The B201 variant comes without an integrated EMC filter. A generator-mode brake chopper is built in. Lenze officially lists this model as a previous product. The i950 series provides a confirmed migration path.

Technical Data

  • Brand: Lenze
  • Model: E82EV1534B201 (base type E82EV153K4B201)
  • Series: 8200 vector
  • Module type: Built-in vector-controlled frequency inverter
  • Rated motor power: 15.0 kW (4-pole asynchronous motor)
  • Rated output current: 32.0 A at 8 kHz switching frequency
  • Max output current: 48.0 A for 60 s (periodic load cycle)
  • Output frequency range: 0 to 650 Hz
  • Switching frequency: 2/4/8/16 kHz selectable, 8 kHz factory setting
  • Mains voltage class: 400 V
  • Supply voltage: 3/PE 320 to 550 V AC (45 to 65 Hz); DC 450 to 775 V alternative
  • Overload capacity: 1.8 x rated torque for 60 s; 2.1 x rated torque for 3 s after enable (15 to 90 kW units)
  • Integrated EMC filter: None (B201 variant)
  • Integrated brake transistor: Generator-mode brake chopper
  • Power loss: 430 W at rated current / 8 kHz
  • Operating temperature range: -10 to +50 °C; derate 2.5 % per °C above +40 °C
  • Storage temperature range: -25 to +60 °C
  • Relative humidity: Average 85 % RH, no condensation (climatic class 3K3 per EN 50178)
  • Protection rating: IP20
  • Dimensions (H x W x D): 350 x 250 x 250 mm
  • Weight: 15.0 kg
  • Interference immunity: Industrial EMC class per EN 50178; external filter needed for class A/B environments

Communication and Compatibility

  • Built-in ports: RS232/485 serial system bus
  • Native protocol: Lenze system bus
  • Fieldbus options via plug-in modules: PROFIBUS DP, CANopen, DeviceNet, INTERBUS, AS-Interface
  • Two control interface slots; three slots on units above 15 kW
  • Migration path: Lenze i950 emulates 8200 vector behaviour via i950 PROFIBUS module and L_ICIP library (Lenze AKB 321231/316137)
  • No drop-in same-order-code replacement exists; plan a controlled upgrade

Installation Guide

  • Mount the unit vertically inside a control cabinet with IP20 protection.
  • Keep clear space above and below for airflow. Do not block the heatsink.
  • Wire mains, motor and brake resistor to the marked terminals. Follow local codes.
  • Add an external EMC filter when the site requires class A or B limits.
  • Derate output above +40 °C ambient by 2.5 % per °C.
  • Use the DC 450 to 775 V input option for common DC bus layouts.
  • Set the 8 kHz switching frequency as default; raise it only with derating.

Commissioning and Maintenance Convenience

  • Parameter setup runs through the Lenze keypad or PC tool.
  • Vector control gives stable torque at low speed without extra tuning.
  • Plug-in communication modules let you add fieldbus support later.
  • Fault codes and status LEDs speed up first-line diagnostics.
  • Clean the heatsink and check fan operation at each service interval.
  • Verify DC bus capacitors after long storage before power-up.

Expert Review

The E82EV1534B201 remains a solid choice for plants that already run the 8200 vector family. Its 1.8 x torque boost for 60 s handles heavy starts well. The 2.1 x boost for 3 s covers short shock loads. Engineers value the dual RS232/485 bus and the wide plug-in fieldbus range. The missing EMC filter in the B201 variant means you must plan cabinet filtering. As a legacy item, stock and support depend on remaining inventory. Lenze confirms the i950 migration path, so a long-term upgrade plan is wise.

Manager’s Insight

Buy this unit when you need a proven spare for an existing 8200 vector line. It keeps downtime low without a full cabinet redesign. For new projects, compare the i950 route first. The E82EV1534B201 still offers strong value for 15 kW pumps, fans and conveyors. Ordering the exact suffix matters; the base type is E82EV153K4B201. Confirm your variant before purchase.

Best-Fit Equipment and Applications

  • Pumps and fans with variable flow demand
  • Conveyors and material handling lines
  • Mixers and agitators in process plants
  • Packaging machines with moderate dynamic loads
  • Retrofit projects on 400 V class asynchronous motors
  • Common DC bus systems using 450 to 775 V DC supply

Certification Information

  • Climatic class 3K3 per EN 50178
  • Designed for industrial EMC environments with external filtering
  • CE conformity applies to the 8200 vector family when installed per Lenze guidelines
  • Audit status: OFFICIAL_VERIFIED

Packing List

  • 1 x Lenze E82EV1534B201 frequency inverter
  • 1 x Installation and operating instructions
  • 1 x Terminal and connector accessory set as shipped by Lenze
  • Protective carton with anti-static wrap

Warranty and Shipping

  • 12-month warranty covers manufacturing defects.
  • Orders ship within 12 to 24 hours after payment clears.
  • Courier options: FedEx, UPS, DHL.
  • Tracking number sent at dispatch.

FAQ

  • Q: Is this an active Lenze product?
    A: No. Lenze lists it as a previous product. The i950 series is the official successor.
  • Q: Does the B201 variant include an EMC filter?
    A: No. You must add an external filter for class A or B installations.
  • Q: What is the correct base order code?
    A: The base type is E82EV153K4B201. The input code often omits the K separator.
  • Q: Can I run it from a DC bus?
    A: Yes. It accepts 450 to 775 V DC as an alternative supply.
  • Q: How much overload can it handle?
    A: 1.8 x rated torque for 60 s. It also gives 2.1 x torque for 3 s after enable.
  • Q: Which fieldbus modules fit?
    A: PROFIBUS DP, CANopen, DeviceNet, INTERBUS and AS-Interface plug-in modules.
  • Q: From experience, what fails first in the field?
    A: Cooling fans and DC bus capacitors age first. Check both at every service.
  • Q: What should I check before ordering a spare?
    A: Match the full suffix, the 15 kW rating and the B201 filter option. A wrong suffix changes the fit.

Buying Guide

  • Confirm your motor is a 4-pole 15 kW unit in the 400 V class.
  • Check whether your cabinet already has external EMC filtering.
  • Decide if you need a fieldbus module now or later.
  • For new builds, price the i950 migration before committing to legacy stock.
  • Keep one spare per critical line to cut downtime risk.
  • Verify the exact suffix on your old unit before you order.

Contact our team for stock checks and migration advice: sales@powergearx.com or +86 18030005825 (WhatsApp).

Copyright © 2026 Powergear X Automation Limited. All rights reserved.

Original Source: https://www.powergearx.com/

Specifications

  • BrandLenze
  • Part NumberE82EV1534B201
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “E82EV1534B201 Lenze 8200 Vector 15 kW Inverter | Powergear X”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart