E82EV152K4C000 Lenze 8200 Vector 1.5 kW Inverter

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: E82EV152K4C000

Product details

Product Overview

  • E82EV152K4C000 is a Lenze 8200 vector series built-in vector-controlled frequency inverter.
  • It drives a 1.5 kW four-pole asynchronous motor on a 400 V mains class.
  • Rated output current reaches 3.9 A at the factory 8 kHz switching frequency.
  • Peak current hits 5.9 A for 60 s under periodic load cycles.
  • Output frequency spans 0 to 650 Hz for wide speed control.
  • The C000 variant ships with an integrated EMC filter for cleaner mains behavior.
  • A built-in brake transistor supports fast stops without extra hardware.
  • Overload capability reaches 1.8 x rated torque for 60 s.
  • This unit is a legacy Lenze product with an official migration path to the i950.
  • Lenze confirms the i950 emulates 8200 vector behavior via the i950 PROFIBUS module and L_ICIP library.
  • No drop-in same-order-code replacement exists, so plan a migration project.
  • Typical users include conveyor systems, pumps, fans, and simple machine axes.

Technical Data

  • Brand: Lenze
  • Model: E82EV152K4C000
  • Series: 8200 vector
  • Module type: Built-in vector-controlled frequency inverter
  • Rated motor power: 1.5 kW typical, 4-pole asynchronous motor
  • Rated output current: 3.9 A nominal at 8 kHz
  • Max output current: 5.9 A for 60 s
  • Output frequency range: 0 to 650 Hz
  • Switching frequency: 2, 4, 8, or 16 kHz selectable; 8 kHz factory setting
  • Mains voltage class: 400 V
  • Supply voltage: 3/PE 320 to 550 V AC, 45 to 65 Hz; DC 450 to 775 V DC alternative
  • Power loss: 100 W at rated current and 8 kHz
  • Overload: 1.8 x rated torque for 60 s
  • Integrated EMC filter: Yes, C000 variant
  • Integrated brake transistor: Yes, built-in chopper up to 11 kW
  • Operating temperature: -10 to +55 °C; derate 2.5 percent per °C above +40 °C
  • Storage temperature: -25 to +60 °C
  • Relative humidity: Average 85 percent RH, no condensation, climatic class 3K3 per EN 50178
  • Protection rating: IP20
  • Dimensions (H x W x D): 240 x 60 x 140 mm per official FU 8200 vector catalogue 11/02 rated-data table
  • Weight: 1.6 kg
  • Built-in ports: RS232/485 serial system bus
  • Protocols: Lenze system bus; fieldbus via plug-in modules such as PROFIBUS DP, CANopen, DeviceNet, INTERBUS, and AS-Interface
  • Communication expansion: Two control interface slots

Installation Guide

  • Mount the unit vertically on a flat panel inside a clean cabinet.
  • Keep IP20 protection in mind; the drive needs a protected enclosure.
  • Respect the 240 x 60 x 140 mm footprint and leave airflow space above and below.
  • Connect 3/PE 320 to 550 V AC supply to the mains terminals.
  • Use the integrated EMC filter to reduce mains noise.
  • Wire the motor for a 1.5 kW four-pole asynchronous machine.
  • Set the switching frequency to 2, 4, 8, or 16 kHz as your noise and loss targets demand.
  • Above +40 °C ambient, derate load by 2.5 percent per °C.
  • Keep humidity at an average 85 percent RH without condensation.
  • Add a plug-in communication module for PROFIBUS DP, CANopen, DeviceNet, INTERBUS, or AS-Interface.
  • For questions, reach sales@powergearx.com or +86 18030005825.

Commissioning and Maintenance

  • Use the RS232/485 serial bus for quick parameter access.
  • The 8 kHz factory switching frequency suits most standard motor tasks.
  • Check the 1.8 x rated torque overload window before sizing the motor.
  • Clean the heatsink and fan area on a fixed schedule.
  • Re-tighten power terminals after the first thermal cycles.
  • Log parameter sets for fast spare-unit swaps.
  • Plan the i950 migration early; the 8200 vector is a legacy product.

Compatibility Notes

  • Works with standard 400 V class four-pole asynchronous motors.
  • Fieldbus options cover PROFIBUS DP, CANopen, DeviceNet, INTERBUS, and AS-Interface.
  • Two control interface slots allow flexible communication builds.
  • The official migration path targets the i950 drive family.
  • Lenze confirms the i950 emulates 8200 vector behavior via the i950 PROFIBUS module and L_ICIP library.
  • No drop-in replacement shares the same order code.

Certifications and Compliance

  • Climatic class 3K3 per EN 50178.
  • Integrated EMC filter supports electromagnetic compatibility targets.
  • IP20 protection rating per the official catalogue.
  • Audit status: OFFICIAL_VERIFIED.
  • Last verified: 2026-10.

Packing List

  • One Lenze E82EV152K4C000 frequency inverter
  • One official FU 8200 vector catalogue reference sheet
  • One protective shipping carton

Warranty and Shipping

Manager’s Insight

  • This drive suits teams that still run 8200 vector spares.
  • Buy it as a like-for-like service part, not as a new design choice.
  • The integrated EMC filter and brake chopper save cabinet work.
  • Budget migration time; no same-order-code replacement exists.
  • The i950 path keeps machine behavior close to the original.
  • For bulk spares, ask sales@powergearx.com about stock.

Best-Fit Equipment and Applications

  • Conveyor lines and material handling units
  • Centrifugal pumps and fans
  • Simple machine axes and retrofit projects
  • Packaging and woodworking machines
  • Legacy lines that already use the 8200 vector series

FAQ

  • Q: Is this unit new or used?
    A: Confirm condition with the sales team before you order.
  • Q: Can it replace my old 8200 vector directly?
    A: Yes if your order code matches E82EV152K4C000.
  • Q: Does it include a brake resistor?
    A: No. It includes a brake transistor only.
  • Q: What if I need PROFIBUS?
    A: Add a plug-in module; the drive has two interface slots.
  • Q: How fast is shipping?
    A: Orders leave within 12 to 24 hours by FedEx, UPS, or DHL.
  • Q: What is the warranty term?
    A: 12 months from delivery.
  • Q: Can I run it above +40 °C?
    A: Yes. Derate 2.5 percent per °C.
  • Q: What should I check first on arrival?
    A: Inspect the carton, then verify the nameplate model and rating.
  • Q: How do I pick a spare?
    A: Match the model code, motor power, and mains class before buying.
  • Q: Should I stock one for a critical line?
    A: Yes. Legacy units get harder to source each year.
  • Q: Do you help with migration?
    A: Contact sales@powergearx.com for i950 guidance.

Buying Guide

  • Confirm the 400 V mains class and the 1.5 kW motor rating first.
  • Check the order code E82EV152K4C000 against your old unit.
  • Decide if you need a fieldbus module for PROFIBUS DP, CANopen, DeviceNet, INTERBUS, or AS-Interface.
  • Add spare units for critical legacy lines.
  • Plan the i950 migration path for new builds.
  • Ask about lead time and stock at +86 18030005825.

Copyright © 2026 Powergear X Automation Limited. All rights reserved.

Original Source: https://www.powergearx.com/

Specifications

  • BrandLenze
  • Part NumberE82EV152K4C000
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “E82EV152K4C000 Lenze 8200 Vector 1.5 kW Inverter”

Your email address will not be published. Required fields are marked *

Back to Top