Over 50,000 hot-selling automation module components.

DTO163 SIGMATEK DIAS Digital Output Module 16-Channel 24V 2A Fast Switching Reliable PLC Expansion

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: DTO163
Brands:

Product details

Product Overview

  • DTO163 (Art.-No. 05-007-163) is a digital output module from SIGMATEK.
  • It belongs to the DIAS series of modular I/O.
  • It offers 16 outputs that switch positive at 24 V and up to 2 A.
  • Each channel handles short circuits without damage.
  • Yellow LEDs show the signal state for every output.
  • The module saves space and speeds up panel builds.
  • Spring terminals cut wiring time on site.

Technical Data

  • Brand: SIGMATEK
  • Model: DTO163
  • Article number: 05-007-163
  • Series: DIAS
  • Type: Digital output module
  • Outputs: 16 channels, 24 V, positive switching
  • Short circuit protection: Yes, on every channel
  • Current per channel: 2 A maximum
  • Current per 8 channels: 6 A maximum, 100 percent duty
  • Current for the whole module: 10 A maximum, 100 percent duty
  • Breaking energy, inductive load: 0.65 J per channel, 1.95 J per 4 channels
  • Voltage drop when on: 1 V or less
  • Residual current when off: 12 uA or less
  • Switch-on delay: Under 200 us
  • Switch-off delay: Under 2000 us
  • Status display: Yellow LEDs
  • Supply voltage: 18 to 30 VDC, 24 V nominal
  • Load current: Follows the outputs, up to 6 A per group of 8
  • DIAS bus supply: +5 V
  • Bus current draw: 20 mA typical, 40 mA maximum
  • Terminal: DKL 012 (Art.-No. 05-024-012), 17-pin spring strip
  • Operating temperature: 0 to +60 C
  • Storage temperature: -20 to +85 C
  • Weight: About 1.0 kg (0.22 lbs)

Key Values for Engineers

  • Switching range: 18 to 30 VDC at up to 10 A total
  • Switching speed: On in under 200 us, off in under 2000 us
  • Response speed: Fast enough for valves, relays and small drives
  • Voltage accuracy: Drop stays at 1 V or less
  • Leakage control: Off state leaks 12 uA or less
  • Temperature range: 0 to +60 C for running parts
  • Environmental resistance: Built for cabinet use inside control panels
  • Interference resistance: Short circuit protection guards each channel

Installation Guide

  • Snap the module onto the DIAS bus rail.
  • Feed 24 VDC to the supply pins.
  • Wire loads to the 17-pin spring terminal.
  • Strip wire to the length in the manual.
  • Push each wire into the spring clamp.
  • Keep total current under 6 A per group of 8.
  • Keep module current under 10 A.
  • Check the yellow LEDs after power up.

Setup and Maintenance

  • No calibration is needed. The module works on power up.
  • Read signal state from the yellow LEDs.
  • Check terminal grip at each service visit.
  • Clear dust from the vents and face.
  • Swap a failed channel by moving the load wire.
  • Replace the DKL 012 strip if a clamp breaks.

Best Fit Devices and Applications

  • Drives solenoid valves and small actuators.
  • Switches relays, lamps and signal towers.
  • Runs small DC motors and brake coils.
  • Fits conveyor, packaging and assembly lines.
  • Works in machine tools and test stands.
  • Suits building automation and door control.
  • Expands SIGMATEK PLC systems with more outputs.

Compatibility

  • Plugs into the SIGMATEK DIAS bus system.
  • Pairs with other DIAS input and output modules.
  • Works with SIGMATEK controllers that host DIAS racks.
  • Takes the DKL 012 terminal for quick field wiring.

Packing List

  • 1 x SIGMATEK DTO163 output module
  • 1 x document pack
  • Terminal DKL 012 may ship separately. Confirm at order.

FAQ

  • Can this module drive a solenoid valve directly?
  • Yes, if the coil draws 2 A or less and the total stays within group limits.
  • What happens when a wire shorts to ground?
  • The channel cuts off on its own. It recovers after you clear the fault.
  • Can I run all 16 outputs at full load?
  • No. Keep the module total at 10 A or less.
  • Does the module need a separate 24 V feed?
  • Yes. The outputs draw their current from the 24 V supply pins.
  • How do I spot a blown output?
  • Compare the yellow LED with the command from the PLC.
  • Can I mix inductive and lamp loads?
  • Yes. Stay within the breaking energy limit for inductive loads.
  • Why does an output stay slightly on?
  • Small leakage current can light a sensitive LED. Add a bleed resistor.
  • Is the spring terminal sold with the module?
  • Check the part number at order. DKL 012 has its own article number.

Specifications

  • BrandSIGMATEK
  • Part NumberDTO163
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “DTO163 SIGMATEK DIAS Digital Output Module 16-Channel 24V 2A Fast Switching Reliable PLC Expansion”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart