Product details
Product Overview
The Sigmatek CSTO082 is a safety digital output module. It works with the C-DIAS automation system. It serves industrial automation and machine safety control. The module gives 8 safe output channels. Each channel meets IEC/EN 61131. It reaches SIL 3 / SIL CL 3 and Performance Level e, Category 4. Use it where fast, safe shutoff matters.
Technical Data
- Brand: Sigmatek
- Model: CSTO082
- Series: C-DIAS
- Type: Safety digital output module
- Output Channels: 8 safe digital outputs
- Standard: IEC/EN 61131
- Rated Output Voltage: +24 V DC
- Minimum: +18 V
- Maximum: +30 V
- Output Current:
- Per channel: 2 A max
- Per output group (2 outputs): 2 A max
- Whole module: 8 A max up to 45 °C
- Whole module: 6 A max up to 50 °C
- Whole module: 4 A max up to 55 °C
- Timing:
- Turn-on delay: under 200 µs
- Turn-off delay: under 1 ms
- Cut-off test signal: under 1.5 ms
- Inductive Load Data:
- Brake voltage at switch-off: about 0.85 V
- Switch-off energy: 0.4 J per channel
- Switch-off energy: 1.2 J whole module
- Supply:
- Rated voltage: +24 V DC from C-DIAS bus
- Range: +18 V to +30 V
- Bus +5 V supply: about 50 mA
- Bus +24 V supply: about 90 mA
- Max voltage interrupt time: 10 ms
- Safety Ratings:
- SIL 3 / SIL CL 3 per EN/IEC 62061
- PL e, Cat. 4 per EN ISO 13849
- Environment:
- Operating temperature: 0 to 55 °C
- Protection class: IP 20
- Supply has no reverse polarity protection
- Other Features:
- Short-circuit proof
- Standard: UL 508 (E247993)
Best Fit Devices and Use Cases
- Safety PLC cabinets in machine cells
- Robot cells that need fast safe stop
- Press and stamping lines
- Conveyor and handling systems
- Packaging machines with guard doors
- Plant sections with C-DIAS control
- Brake and valve control with inductive loads
FAQ
Q: How many safe channels does this unit drive?
A: It drives 8 safe outputs. Each one follows IEC/EN 61131.
Q: What current can one channel carry?
A: One channel carries up to 2 A. A group of two outputs shares the same 2 A limit.
Q: Why does the module current drop at high heat?
A: Heat limits the module. It allows 8 A up to 45 °C, 6 A up to 50 °C, and 4 A up to 55 °C. Plan the load for your cabinet temperature.
Q: How fast does an output turn off?
A: The turn-off delay stays under 1 ms. Turn-on takes under 200 µs. This suits fast safety stop circuits.
Q: What should I check if an output stays off?
A: First check the C-DIAS bus supply. It must stay within +18 V to +30 V. Then look for a short or an overload on that channel. Note the module has no reverse polarity protection, so check wiring polarity.
Q: Can it switch brake or valve loads?
A: Yes. It handles inductive loads. Switch-off energy is 0.4 J per channel and 1.2 J for the whole module. Add a freewheel path if your load exceeds this.
Q: What safety level can I reach?
A: You can reach SIL 3 / SIL CL 3 and PL e, Cat. 4. These ratings depend on correct wiring and system design.