Product details
Product Overview
ATV930U15N4Z is a Schneider Electric Altivar Process ATV930 three-phase variable speed drive. It works with 380 to 480 V supplies. This cabinet integration version has IP20 protection. A built-in braking unit cuts external parts. Dual ND/HD rating gives one drive two power classes.
- ND Normal Duty: 1.5 kW (2 HP), 120% overload for 60 s.
- HD Heavy Duty: 0.75 kW (1 HP), 150% overload for 60 s.
- Motor control: async, PM and synchronous reluctance motors. Open-loop and closed-loop vector control.
- Safety: STO function rated SIL3 and Cat. PL e.
- Best fit: pumps, fans, conveyors and simple machines in panels.
Technical Data
- Brand: Schneider Electric
- Model: ATV930U15N4Z
- Series: Altivar Process ATV930
- Supply: 380 to 480 V three-phase, -15%/+10%, 50/60 Hz
- Output frequency: 0.1 to 599 Hz
- Switching frequency: 4 kHz nominal. Auto derating above nominal.
- ND input current: 3.0 A at 380 V, 2.6 A at 480 V
- ND output current: 4.0 A continuous, 4.8 A for 60 s
- ND apparent power: 2.2 kVA at 380 V
- HD input current: 1.7 A at 380 V, 1.5 A at 480 V
- HD output current: 2.2 A continuous, 3.3 A for 60 s
- HD apparent power: 1.2 kVA at 380 V
- Braking: built-in chopper. External resistor min. 56 Ω.
- Short-circuit rating: SCCR up to 50 kA
- EMC filter: Category C2 integrated
Inputs and Outputs
- Analog inputs: 3 total. Two are 0 to 10 V or 0/4 to 20 mA. One is 0 to ±10 V.
- Probe input: PTC, PT100, PT1000 or KTY84
- Digital inputs: 8 at 24 V DC. Positive or negative logic.
- Digital output: 1 assignable. Can send pulse train output (PTO).
- Analog outputs: 2. Set as 0 to 10 V or 0/4 to 20 mA.
- Relay outputs: 3 total. One NO/NC plus two NO.
- Safety inputs: 2 for the STO function
- Expansion: up to 3 extra I/O modules
Communication
- Built-in ports: Ethernet dual-port switch (RJ45) and Modbus serial port (RJ45)
- Protocols: EtherNet/IP, Modbus TCP, Modbus RTU
- Option slot: one fieldbus module. PROFINET, PROFIBUS DP V1, CANopen, DeviceNet, EtherCAT or POWERLINK.
- Cyber security: Achilles Level 2 certified
Environment and Protection
- Operating temperature: 0 to +40 °C standard. Derate from 40 to 50 °C.
- Storage temperature: -40 to +70 °C
- Humidity: 5 to 95%, non-condensing
- Altitude: no derating to 1000 m. Above 1000 m, derate 1% per 100 m up to 3000 m.
- Protection rating: IP20. Bottom power terminals IP00.
- Environmental class: IEC 60721-3-3 class 3C3 / 3S3 / 3M3
- Noise immunity: C2 EMC filter and shielded wiring limit interference.
Physical Data
- Dimensions: 285 x 130 x 196 mm (H x W x D)
- Power loss: 74 W in ND, 47 W in HD at nominal load
- Minimum air flow: 38 m3/h
- Terminal torque: 2.5 N·m for frame 1 to 3 power terminals
- Weight: not published by the manufacturer
Installation Guide
- Mount the drive upright inside a cabinet.
- Keep 100 mm free space above and below the unit.
- Keep 10 mm free space in front of the unit.
- Use the C2 filter and shielded motor cable to cut noise.
- Tighten power terminals to 2.5 N·m.
- Add an external braking resistor of at least 56 Ω when braking.
Setup and Maintenance
- Fast setup through the built-in keypad or a PC tool.
- Clear text menus cut training time.
- Dual rating means one spare part covers two duties.
- The STO input simplifies safe stop wiring.
- Firmware and settings load through the Ethernet port.
- Few parts and front access make service quick.
Compatibility Notes
- Works with async, PM and synchronous reluctance motors.
- Fits panel and cabinet builds with IP20 protection.
- Connects to EtherNet/IP, Modbus TCP and Modbus RTU networks.
- Option slot adds PROFINET, PROFIBUS DP V1, CANopen, DeviceNet, EtherCAT or POWERLINK.
- Up to 3 extra I/O modules fit one drive.
Certifications
- UL 508C and UL 61800-5-1
- EN/IEC 61800-3, category C2/C3
- EN/IEC 61800-5-1
- IEC 61508 and IEC 13849-1 for STO
- Achilles Level 2
- REACH and SEMI F47-0706
Packing List
- 1 x ATV930U15N4Z drive
- 1 x installation manual
- 1 x safety information sheet
- Braking resistor and fieldbus modules are not included.
FAQ
Q: Can this drive run a 1.5 kW motor?
A: Yes, in ND mode. In HD mode the limit is 0.75 kW.
Q: Does it need an external braking resistor?
A: Yes, for braking. The built-in chopper needs a resistor of at least 56 Ω.
Q: Which networks work out of the box?
A: EtherNet/IP and Modbus TCP over Ethernet, plus Modbus RTU over serial.
Q: Can I add PROFINET later?
A: Yes. One option slot takes a PROFINET module.
Q: What is the top temperature without derating?
A: 40 °C. Derate from 40 to 50 °C.
Q: From experience, what is the most common install mistake?
A: Tight space around the unit. Keep 100 mm above and below.
Q: From experience, what saves the most setup time?
A: Copy settings from a known unit through the Ethernet port.
Q: From experience, how do I avoid nuisance trips?
A: Use shielded motor cable and a good ground. Check the C2 filter wiring.