Product details
Product Overview
ATV930U07N4Z is a Schneider Electric variable speed drive from the Altivar Process ATV930 series. It is built for cabinet integration.
Supply and ratings. This three-phase drive works with 380…480 V supplies. Moreover, it offers dual ND/HD ratings and a built-in braking unit.
Use case and design. The drive fits industrial motor control tasks that need flexibility and safety. In addition, its compact IP20 design suits panel mounting.
Value for the panel builder. Therefore, it serves both light and heavy duty applications well. Furthermore, the dual rating means one unit covers two load profiles.
Technical Specifications
Identity
- Brand: Schneider Electric
- Model: ATV930U07N4Z
- Series: Altivar Process ATV930
- Module type: Three-phase variable speed drive, cabinet integration, IP20
Motor and Output
- Motor power (ND): 0.75 kW (1 HP), 120% overload for 60 s
- Motor power (HD): 0.37 kW (0.5 HP), 150% overload for 60 s
- Output frequency range: 0.1…599 Hz
- Switching frequency: 4 kHz nominal for this frame size
Electrical
- Supply voltage: 380…480 V three-phase, -15%/+10%, 50/60 Hz
- ND input current: 1.5 A at 380 V; 1.3 A at 480 V
- HD input current: 0.9 A at 380 V; 0.8 A at 480 V
- ND continuous output current: 2.2 A max
- HD continuous output current: 1.5 A max
- ND transient current (60 s): 2.6 A
- HD transient current (60 s): 2.3 A
- SCCR: 50 kA maximum
- EMC filter: Category C2 integrated
Safety and Braking
- Integrated safety: STO function, SIL3 / Cat. PL e
- Braking: Built-in dynamic brake transistor; external resistor required
- Minimum brake resistor: 56 Ω
I/O
- Analog inputs: 3 total (2 configurable 0…10 V or 0/4-20 mA; 1 configurable 0…±10 V)
- Digital inputs: 8, 24 V DC, positive or negative logic
- Digital output: 1 assignable, configurable as Pulse Train Output
- Analog outputs: 2, configurable 0…10 V or 0/4-20 mA
- Relay outputs: 3 (1 NO/NC + 2 NO)
- Safety inputs: 2 for STO
- I/O expansion: Up to 3 optional modules
Communication
- Built-in ports: 1 Ethernet dual-port switch (RJ45); 1 Modbus serial port (RJ45)
- Protocols: EtherNet/IP, Modbus TCP, Modbus RTU/TCP
- Fieldbus option slot: 1 (PROFINET, PROFIBUS DP V1, CANopen, DeviceNet, EtherCAT, POWERLINK)
- Cybersecurity: Achilles Level 2 certified
Environment and Physical
- Operating temperature: 0 to +40 °C standard; derating up to 50 °C
- Storage temperature: -40 to +70 °C
- Relative humidity: 5 to 95%, non-condensing
- Altitude: Up to 1000 m no derating; above 1000 m derate 1% per 100 m
- Protection rating: IP20 (bottom power terminals IP00)
- Dimensions (H×W×D): 285 x 130 x 196 mm
- Power dissipation: 50 W (ND) / 39 W (HD) at nominal load
- Minimum air flow: 38 m3/h
- Terminal tightening torque: 2.5 N·m (Frame 1-3 power terminals)
- Installation clearance: 100 mm above and below, 10 mm front
- Weight: Not published by manufacturer
Installation Guide
Placement. Mount the drive in a cabinet with IP20 protection. Keep 100 mm clearance above and below the drive. Also keep 10 mm clearance at the front.
Cooling. Provide 38 m3/h minimum air flow for cooling.
Wiring. Tighten power terminals to 2.5 N·m for frame sizes 1-3. Connect the STO safety inputs properly for SIL3 / PL e operation. In addition, label the safety wiring clearly for later checks.
Braking and altitude. Use a minimum 56 Ω external brake resistor if braking is needed. Finally, follow altitude derating rules: 1% current reduction per 100 m above 1000 m.
Commissioning and Maintenance Ease
Network setup. The dual-port Ethernet switch simplifies network wiring. In addition, a built-in Modbus serial port supports quick setup.
Flexible I/O. Up to 3 I/O expansion modules add flexibility without replacing the drive. Moreover, the assignable digital output can work as Pulse Train Output. Configurable analog inputs accept voltage, current, or temperature probes.
Safety and service. The STO function also supports safe machine maintenance. Clear terminal torque and clearance rules speed up installation.
Diagnostics. Furthermore, built-in diagnostics help shorten downtime. Therefore, routine checks take less time and cause fewer errors.
Compatibility Notes
Motor types. Works with asynchronous motors (open-loop sensorless flux vector, closed-loop with encoder). Likewise, it works with synchronous PM motors (open-loop and closed-loop vector control). It also works with synchronous reluctance motors (open-loop and closed-loop vector control).
Networks. Built-in EtherNet/IP and Modbus TCP support common industrial networks. The fieldbus option slot accepts PROFINET, PROFIBUS DP V1, CANopen, DeviceNet, EtherCAT, and POWERLINK modules.
Expansion and spares. Therefore, optional I/O modules expand analog input, digital input, and relay output capacity. As a result, one drive covers many motor and network combinations. Moreover, the same option slot keeps spares simple across projects.
Certifications
- UL 508C, UL 61800-5-1
- EN/IEC 61800-3 (category C2/C3)
- EN/IEC 61800-5-1
- IEC 61508 (SIL3)
- ISO 13849-1 (Cat. PL e)
- Achilles Level 2
- REACH
- SEMI F47-0706
- In addition, the drive meets EMC category C2 with its integrated filter.
Packing List
- ATV930U07N4Z drive unit
- Installation manual reference NHA80932 (as cited in technical data)
- Safety function terminal labels
- Quick start guide (standard Schneider Electric delivery)
- Note: External braking resistor not included; order it separately
- Moreover, check the box for the safety labels before installation.
FAQ
Motor Power
Q: What motor power can this drive handle?
A: It handles 0.75 kW (1 HP) in Normal Duty and 0.37 kW (0.5 HP) in Heavy Duty. Overload capacity is 120% for 60 s in ND and 150% for 60 s in HD. Therefore, pick the rating that matches your load profile.
Braking
Q: Does the drive include a braking resistor?
A: No. The drive has a built-in dynamic brake transistor. You must add an external braking resistor. The minimum allowed value is 56 Ω. In addition, size the resistor for your braking duty.
Motor Compatibility
Q: Can I use this drive with a permanent magnet motor?
A: Yes. It supports synchronous PM motors in open-loop and closed-loop vector control. It also supports synchronous reluctance motors. Moreover, encoder feedback improves low-speed torque.
Safety
Q: What safety function is integrated?
A: It has one STO (Safe Torque Off) function. It meets SIL3 and Cat. PL e requirements. Two dedicated safety inputs are available. Therefore, you can wire a safety relay directly.
Network Connection
Q: How do I connect the drive to my network?
A: The drive has a built-in dual-port Ethernet switch for EtherNet/IP and Modbus TCP. It also has a Modbus serial port. You can add one fieldbus module for PROFINET, EtherCAT, or other protocols. In addition, the dual port allows daisy-chain wiring.
Temperature Limits
Q: What is the maximum ambient temperature?
A: Standard operation is 0 to +40 °C. You can use it up to 50 °C with derating. Follow the catalog derating tables for current reduction. Moreover, keep the cabinet air flow above 38 m3/h.
Field Experience: Clearance
Q: From experience, what is a common installation mistake?
A: Many users forget the minimum 100 mm clearance above and below the drive. Without this space, airflow drops below 38 m3/h and the drive may overheat. Therefore, always check clearance before tightening terminals. In addition, verify the 10 mm front gap after closing the cabinet.
Field Experience: Brake Resistor
Q: From experience, how should I handle brake resistor selection?
A: Do not go below 56 Ω. A lower resistance can damage the brake transistor. Also mount the resistor outside the cabinet or in a well-ventilated area, because it dissipates heat during braking. Moreover, check the resistor power rating against your duty cycle.
Weight and Shipping
Q: Does this model come with a published weight?
A: Schneider Electric does not publish a weight for this model in the official catalog. The order table shows a dash. Check the packaging label or ask your supplier for the shipping weight. In addition, plan lifting aids if you combine several drives in one panel.















There are no reviews yet.