Over 50,000 hot-selling automation module components.

ATV610D75N4Z 100 HP Schneider Easy Altivar 610 Pump and Fan Drive

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: ATV610D75N4Z
Brands:

Product details

ATV610D75N4Z | Schneider Electric Easy Altivar 610 75 kW Drive for Pumps and Fans

This is the ATV610D75N4Z. Schneider Electric builds it in the Easy Altivar 610 range. The drive is sized for large pumps and fans. It rates 75 kW (100 HP) in normal duty, and 55 kW (75 HP) in heavy duty. It runs on 380 to 460 V three-phase power. A category C3 EMC filter is inside. A DC choke cuts mains harmonics. The N4Z ships without a keypad to keep cost low. Add the VW3A1113 pad when you need a screen.

Name Plate

  • Brand: Schneider Electric
  • Model: ATV610D75N4Z
  • Series: Easy Altivar 610
  • Type: Variable speed drive (AC frequency inverter) for pumps and fans
  • Frame size: 5

Power Core

  • Normal duty: 75 kW (100 HP), 145 A continuous
  • Normal duty transient: 160 A for 60 s
  • Heavy duty: 55 kW (75 HP), 106 A continuous
  • Heavy duty transient: 159 A for 60 s
  • Overload bands: ND 110% for 60 s or 120% for 20 s; HD 150% for 60 s
  • Output frequency: 0.1 to 500 Hz
  • Switching frequency: 1 to 8 kHz, 2.5 kHz nominal; derate above nominal

Line Feed

  • Voltage: 380 to 460 V AC, 50/60 Hz, three-phase
  • Input current: 147.9 A at 380 V; 130.2 A at 460 V (normal duty)
  • Apparent power: 103.7 kVA at 460 V
  • SCCR: 22 kA maximum
  • DC choke: built in
  • Harmonics: THDi under 10% only with the optional VW3A46xxx filter
  • Losses: 1637 W in an enclosed cabinet at nominal current

Motor Control

  • U/f Standard: STD mode
  • U/f 5-point: UF5 mode
  • U/f Quadratic: UFQ mode for fans and pumps
  • Sync PM motor: SYNU open-loop mode
  • Reluctance motor: SRVC mode
  • Motor types: three-phase async and sync motors, open loop

I/O Branches

  • Analog inputs
    • 3 total
    • Software set to 0 to 10 V or 0 to 20 mA
    • Use for voltage, current, temperature probe or water level
  • Digital inputs
    • 6 x 24 V DC
    • 2 can act as pulse inputs
  • Analog outputs: 2, software set to 0 to 10 V or 0 to 20 mA
  • Relay outputs: 3, configurable logic
  • Expansion slot A
    • Extended I/O module VW3A3203
    • Extended relay module VW3A3204
    • PROFIBUS DP V1 module VW3A3607

Brake Path

  • Terminals: PA/+ and PB for an external braking resistor
  • Internal chopper: external resistor needed
  • Note: no braking torque figure is published by the maker

Network Branches

  • Field network port
    • RJ45 at the bottom of the control block
    • Modbus RTU over RS485
    • Swaps process data with other devices
  • HMI port
    • RJ45 at the front of the control block
    • Links the VW3A1113 pad
    • Links Harmony or Magelis panels
    • Links a configuration loader
  • Built-in display: none; the N4Z ships without a keypad

Weather and Coating

  • Protection: IP20; IP40 on the top face
  • Running temperature: -15 to +45 °C with no derating; up to +60 °C with derating
  • Storage temperature: -40 to +70 °C
  • Humidity: 5 to 95%, no condensation
  • Height: no derating to 1000 m; derate from 1000 to 3000 m
  • Ambient class: 3C3 / 3S3 to IEC/EN 60721
  • Mechanical class: 3M3 to IEC/EN 60721
  • Coating: conformal coat on the circuit boards
  • Overvoltage: relay supply must be OVC II, or add an isolation transformer

Body Size

  • Dimensions (H×W×D): 762 x 290 x 323 mm
  • Weight: 52.045 kg (114.7 lb), no packaging
  • Power terminal torque: 25 N·m (frame 5)
  • Fan: field-replaceable in under 5 minutes, no special tools

Where It Shines

  • Large water pumps in treatment and supply plants
  • Booster stations with high flow demand
  • HVAC supply and return fans in big buildings
  • Cooling tower fans that run all day
  • Industrial exhaust fans in process plants
  • Irrigation main pumps on large farms

Mount and Wire

  • Mount vertical, within ±10°.
  • Keep 100 mm free at the top, 100 mm at the bottom and 10 mm in front.
  • Tighten power screws to 25 N·m.
  • Motor cable can reach 150 m shielded or 200 m unshielded.
  • Add a dv/dt filter above 50 m.
  • Fit a resistor on PA/+ and PB for braking duty.
  • Derate power above 1000 m or above 45 °C.

Commission and Care

  • Plug the VW3A1113 pad into the HMI port when you need local setup.
  • Use the field network RJ45 for Modbus control from the PLC.
  • Set UFQ mode for fan and pump loads to save energy.
  • Swap the fan in under 5 minutes if it wears out.
  • The conformal coat helps in damp or dirty rooms.
  • Store settings on a loader for fast drive swaps.

Match and Fit

  • Runs async, PM and reluctance motors in open loop.
  • Works on 380 to 460 V grids at 50 or 60 Hz.
  • Adds PROFIBUS DP V1 through slot A.
  • Takes extra I/O or relay boards in the same slot.
  • Pairs with Modbus networks over RS485.

Approvals

  • CE marking, EMC directive
  • CSA C22.2 No. 274 (Canada)
  • IEC/EN 61800-5-1 overvoltage rules
  • IEC/EN 60721 classes 3C3/3S3 and 3M3
  • No UL listing is published in the official catalog

In the Box

  • 1 x ATV610D75N4Z drive
  • 1 x printed installation manual
  • 1 x safety sheet
  • Terminal parts as packed by Schneider Electric
  • Keypad VW3A1113 and braking resistor sold apart

FAQ

Will this unit handle a 100 HP fan?

Yes in normal duty. It gives 145 A continuous. Check the motor plate first. Fans rarely pull full current once they reach speed.

Why is the SCCR higher on this frame?

Bigger drives meet higher fault levels. This model rates 22 kA. Match the upstream breaker or fuse to that value for safe protection.

Do I need an external line reactor?

The DC choke handles most of it. Add a reactor when the supply is weak or cables run far. This keeps the bus steady.

How much heat goes into the cabinet?

About 1637 W at full current. Plan real airflow or a cooling unit. Small enclosures will overheat fast.

Can I use the built-in filter for the whole plant?

No. The C3 filter serves this drive’s own motor cable. Keep shielded runs at or under 150 m to hold EMC levels.

What is a common mistake on large frames?

Loose power lugs. They heat up and trip the drive under load. Use a torque wrench and hit 25 N·m on every terminal.

Specifications

  • BrandAllen-Bradley
  • Part Number22A-B012F104
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “ATV610D75N4Z 100 HP Schneider Easy Altivar 610 Pump and Fan Drive”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart