Product details
ATV610D55N4Z – Schneider Electric Easy Altivar 610 Pump and Fan Drive
The ATV610D55N4Z is a variable speed drive from Schneider Electric. It belongs to the Easy Altivar 610 series. This drive runs pumps and fans. It delivers 55 kW (75 HP) at 380…460 V three-phase. Moreover, it has an integrated C3 EMC filter. Therefore, it saves panel space and cuts wiring time.
Technical Specifications
- Brand: Schneider Electric
- Model: ATV610D55N4Z
- Series: Easy Altivar 610
- Product Type: Variable speed drive (AC frequency inverter)
- Frame Size: 5
Drive Ratings and Control
- Normal duty power: 55 kW (75 HP)
- Heavy duty power: 45 kW (60 HP)
- Output frequency: 0.1…500 Hz
- Switching frequency: 1…8 kHz adjustable; 2.5 kHz nominal
- Motor types: Three-phase asynchronous and synchronous motors (open loop)
- Control modes: U/f Standard (STD), U/f 5-point (UF5), U/f Quadratic (UFQ for fans and pumps), open-loop PMSM (SYNU), reluctance motor (SRVC)
- Starting torque: Not published in official catalog or installation manual
- Braking: External braking-chopper resistor terminals (PA/+, PB); no integrated braking transistor rating published
- Overload duty: Normal duty 110% for 60 s (or 120% for 20 s); heavy duty 150% for 60 s
I/O and Signal Performance
- Analog inputs: 3, software-configurable 0…10 V / 0…20 mA (voltage, current, temperature probe, or water level sensor)
- Digital inputs: 6 at 24 V DC; 2 can work as pulse inputs
- Analog outputs: 2, software-configurable 0…10 V / 0…20 mA
- Relay outputs: 3, configurable relay logic
- I/O expansion: Slot A accepts Extended I/O module VW3A3203 or Extended relay module VW3A3204
- Operating temperature: -15…+45 °C without derating; up to +60 °C with power derating
- Storage temperature: -40…+70 °C (frames 1-6)
- Relative humidity: 5…95% without condensing
- Environmental class: 3C3 / 3S3 and 3M3 per IEC/EN 60721
- Conformal coating: Electronic cards have protective coating
- Interference immunity: Integrated C3 EMC filter
Communication and Compatibility
- Built-in ports: 2 RJ45 Modbus serial-link ports
- Field network port: Bottom of control block; exchanges process data via Modbus serial link
- HMI port: Front of control block; connects VW3A1113 keypad, Harmony/Magelis HMI, or configuration loader
- Protocols: Modbus RTU over RS485 physical layer (A/B/SGND terminals)
- Communication expansion: Slot A accepts PROFIBUS DP V1 module VW3A3607 (9-way SUB-D, Profidrive and CiA402 profiles)
- Integrated HMI: None; VW3A1113 keypad sold separately
Electrical Data
- Supply voltage: 380…460 V AC, 50/60 Hz, three-phase
- Maximum input current: 111.5 A at 380 V; 99.7 A at 460 V (normal duty)
- Apparent power: 79.5 kVA at 460 V
- SCCR (prospective short-circuit current): 22 kA maximum
- Maximum continuous output current: 120 A (normal duty); 88 A (heavy duty)
- Maximum transient current (60 s): 132 A (normal and heavy duty)
- Input current harmonics: Integrated DC choke reduces distortion; THDi < 10% only with optional external passive filter VW3A46xxx
- Power dissipation (enclosed cabinet): 1100 W total at nominal current
- Cooling: Fan cooled; fan field-replaceable in under 5 minutes without special tools
- Power terminal tightening torque: 25 N·m (frame 5)
Physical and Installation
- Dimensions (H×W×D): 762 × 290 × 323 mm
- Weight: 52.045 kg (114.7 lb) without packaging
- Protection rating: IP20 (IP40 on top of product)
- Mounting: Vertical ±10° for cooling; clearance ≥100 mm top, ≥100 mm bottom, ≥10 mm front (frames 1–5)
- Maximum motor cable length: 150 m shielded / 200 m unshielded without dv/dt filter; output filter recommended above 50 m
- Altitude: Up to 1000 m no derating; 1000…3000 m with derating
- Overvoltage category: Relay output supply must be OVC II per IEC/EN 61800-5-1; otherwise use an isolation transformer
Certifications
- Certifications: CE marking (EMC directive); CSA C22.2 No. 274 (Canada); no UL listing published in official catalog
Best Fit Applications
- Water supply pumps: Constant pressure and flow control in buildings and plants
- HVAC fans: Air handling units and cooling towers with variable torque loads
- Wastewater pumps: Lift stations and treatment plant circulation
- Cooling pumps: Chiller loops and industrial process cooling
- Booster sets: Multi-pump systems with Modbus network control
- Irrigation systems: Field pumps with remote HMI monitoring
Commissioning and Maintenance Convenience
- Keypad option: VW3A1113 connects via front RJ45 HMI port for setup
- Fan replacement: Field-replaceable in under 5 minutes; no special tools needed
- Conformal coating: Protects cards in dusty and humid plant rooms
- Integrated DC choke: Cuts harmonic distortion and saves cabinet space
- I/O and relay modules: Slot A accepts VW3A3203 or VW3A3204 for quick expansion
- PROFIBUS DP V1: VW3A3607 module plugs into Slot A for plant network integration
What’s in the Box
- 1 x ATV610D55N4Z variable speed drive
- 1 x Installation manual EAV64381
- 1 x Quick start guide
- Terminal labels as shipped by Schneider Electric
- Note: Plain text display terminal VW3A1113 not included
FAQ
Is a keypad included with the ATV610D55N4Z?
No. This N4Z version ships without a display terminal. However, you can order the VW3A1113 keypad separately. Then plug it into the front RJ45 HMI port for setup and monitoring.
Which loads should I run on normal duty?
Use normal duty for pumps and fans with steady torque. The drive then delivers 55 kW and 120 A continuous. In contrast, pick heavy duty (45 kW, 88 A) for high overload starts.
How do I cut harmonics below 10% THDi?
The built-in DC choke lowers distortion. However, THDi under 10% needs the optional external passive filter VW3A46xxx. Therefore, plan this filter in your panel design.
What is the longest motor cable I can use?
You can run 150 m shielded or 200 m unshielded cable without a dv/dt filter. Nevertheless, add an output filter when the cable exceeds 50 m.
Can I connect this drive to a plant network?
Yes. Two RJ45 Modbus ports are built in. Moreover, Slot A accepts the VW3A3607 PROFIBUS DP V1 module. As a result, you can link the drive to a plant control system.
What spare part should I keep on site?
Keep one spare cooling fan. It is field-replaceable in under 5 minutes without special tools. Furthermore, check fan airflow every service visit to avoid thermal derating.















There are no reviews yet.