Product details
ATV320U75N4WS: Reliable Power for 7.5 kW Machines
ATV320U75N4WS is a Schneider Electric drive for strong three-phase machines. It delivers 7.5 kW (10 HP) at 380…500 V. The IP65 case blocks dust and water jets. So it suits wet and dirty plant floors. A Vario disconnect switch saves wiring time. The category C2 EMC filter is built in. Also, the short-circuit rating reaches 22 kA. However, dynamic braking needs an external resistor. Therefore, plan that part before you buy. The drive runs induction and PM motors. In addition, CANopen and Modbus ports work right away.
Technical Specifications
- Brand: Schneider Electric
- Model: ATV320U75N4WS
- Series: Altivar Machine ATV320
- Type: IP65 wall-mount three-phase drive with Vario disconnect switch
- Motor Power: 7.5 kW (10 HP) at 380…500 V
- Supply: 380…500 V three-phase, 50/60 Hz, -15%/+10%
- Input Current: 26.5 A at 380 V; 18.7 A at 500 V
- Output Current (In): 17.0 A at 4 kHz
- Transient Output: 25.5 A for 60 s (150% of In)
- Output Frequency: 0.1 to 599 Hz
- Switching Frequency: 2 to 16 kHz; factory 4 kHz (derate above 4 kHz)
- Overload Torque: 200% Tn over-torque; 170% Tn braking
- Brake Resistor: 27 Ω minimum, external
- Analog Inputs: 3 total — ±10 V differential, 0…10 V, 0-20 mA
- Digital Inputs: 6 total — 4 configurable, 1 PTC probe, 1 pulse (20 kHz)
- Outputs: 1 digital (100 mA), 1 analog (10-bit), 2 relay, 1 pulse (32 kHz)
- Safety: STO up to SIL3/PLe; SS1, SLS, SMS, GDL
- Ports: 1 RJ45 for CANopen and Modbus Serial line
- Expansion: 1 slot — EtherNet/IP, PROFIBUS DP V1, DeviceNet, EtherCAT, POWERLINK, PROFINET
- Apparent Power: 16.2 kVA at 500 V
- SCCR: 22 kA
- Power Loss: 229 W at In
- Motor Cable: 10 m shielded at 4 kHz (C2/C3)
- Operating Temperature: -10 to +50 °C no derating; up to 60 °C with derating
- Storage Temperature: -25…+70 °C
- Humidity: 5…95%, no condensation
- Altitude: 1000 m no derating; 1% per 100 m above
- Protection: IP65
- Size (H×W×D): 521 x 320 x 335 mm
- Weight: 22.700 kg (50.044 lb)
- Terminal Torque: 1.2 to 1.5 N·m (Frame 4)
- Wire Size: 4 to 16 mm² (Frame 4)
- Clearance: 100 mm around drive; mount vertical ±10°
Installation Guide
- Mount the drive vertical. Tilt no more than ±10°.
- Leave 100 mm free space on all sides. This keeps airflow strong.
- Use 4 to 16 mm² wires on Frame 4 terminals.
- Tighten each terminal to 1.2 to 1.5 N·m.
- Keep the shielded motor cable under 10 m for C2/C3.
- Add a 27 Ω or higher brake resistor if you need braking.
- Seal all cable glands. Otherwise, the IP65 rating drops.
Setup and Service
- Set switching frequency from 2 to 16 kHz. Factory value is 4 kHz.
- Derate power above 4 kHz.
- Derate current by 1% per 100 m above 1000 m altitude.
- Plug in the VW3A1111 or VW3A1101 display for fast setup. Then copy settings to other drives.
- Clean the IP65 case with a water jet. Never soak the drive.
- Keep the drive dry. Stop condensation before power-up.
Compatibility Notes
- Runs induction motors and PM motors without a sensor.
- Ships with CANopen and Modbus Serial line.
- Add a module for EtherNet/IP, PROFIBUS DP V1, DeviceNet, EtherCAT, POWERLINK, or PROFINET. Thus one drive fits many networks.
- Fits GV2 breaker brackets, DIN rail plates, UL Type 1 kits, and 90-degree adapters.
Certifications
- UL 508C, UL61800-5-1, CSA 22.2 N274
- EN/IEC 61800-3 (C2/C3), EN/IEC 61800-5-1
- IEC 61800-5-2 up to SIL3, IEC 61508 SIL3, IEC 13849-1 PLe
- IEC 60721-3-3 (3C3/3S2), RCM, EAC, KC
Package Contents
- ATV320U75N4WS drive
- Installation manual NVE41289
- Safety sheet
- Quick start guide
Best Fit: Equipment and Applications
- Heavy conveyors: mining, bulk, and loading lines
- Large mixers: food, chemical, and slurry tanks
- Industrial pumps: high-flow duty in wet rooms
- Palletizers and cartoners: fast packaging lines
- Extruders and crushers: tough shops with dust and washdown
FAQ
- Q: My 7.5 kW motor draws high current on start. What should I check?
A: First check the motor current against the 17.0 A output rating. Then look at the acceleration ramp. A ramp that is too short pulls high current. Finally, confirm the motor wiring matches the supply voltage. - Q: The drive stops with a thermal fault on hot days. Why?
A: Heat builds up when the cabinet is warm. Check the room temperature near the drive. Above 50 °C, you must derate the load. Also clean the cooling fins. Dust blocks airflow and raises heat. - Q: Can I use one resistor value for both 5.5 kW and 7.5 kW drives?
A: No. Each drive needs a resistor sized for its own current. The 7.5 kW unit needs at least 27 Ω. Check manual NVE41289 for the right value. - Q: My sensors act up after I added this drive to the line. What now?
A: Check the motor cable first. Use shielded cable and keep it under 10 m. Then lower the switching frequency. Finally, ground the shield at both ends. - Q: How do I move settings from one drive to another?
A: Use the VW3A1111 or VW3A1101 display. Save the setup from the first drive. Then load it into the next unit. This saves time on multi-drive lines.















There are no reviews yet.