Product details
ATV320U55N4WS: Strong Drive for Heavy Machine Loads
ATV320U55N4WS is a Schneider Electric drive built for demanding three-phase jobs. It delivers 5.5 kW (7.5 HP) at 380…500 V. The IP65 case stops dust and water jets. So it works in wet and dirty plants. A Vario disconnect switch cuts wiring steps. The category C2 EMC filter comes built in. Also, the short-circuit rating is high at 22 kA. However, dynamic braking needs an external resistor. Therefore, size that part before you order. The drive runs induction and PM motors. In addition, CANopen and Modbus ports are ready to use.
Technical Specifications
- Brand: Schneider Electric
- Model: ATV320U55N4WS
- Series: Altivar Machine ATV320
- Type: IP65 wall-mount three-phase drive with Vario disconnect switch
- Motor Power: 5.5 kW (7.5 HP) at 380…500 V
- Supply: 380…500 V three-phase, 50/60 Hz, -15%/+10%
- Input Current: 20.7 A at 380 V; 14.5 A at 500 V
- Output Current (In): 14.3 A at 4 kHz
- Transient Output: 21.5 A for 60 s (150% of In)
- Output Frequency: 0.1 to 599 Hz
- Switching Frequency: 2 to 16 kHz; factory 4 kHz (derate above 4 kHz)
- Overload Torque: 200% Tn over-torque; 170% Tn braking
- Brake Resistor: 27 Ω minimum, external
- Analog Inputs: 3 total — ±10 V differential, 0…10 V, 0-20 mA
- Digital Inputs: 6 total — 4 configurable, 1 PTC probe, 1 pulse (20 kHz)
- Outputs: 1 digital (100 mA), 1 analog (10-bit), 2 relay, 1 pulse (32 kHz)
- Safety: STO up to SIL3/PLe; SS1, SLS, SMS, GDL
- Ports: 1 RJ45 for CANopen and Modbus Serial line
- Expansion: 1 slot — EtherNet/IP, PROFIBUS DP V1, DeviceNet, EtherCAT, POWERLINK, PROFINET
- Apparent Power: 12.6 kVA at 500 V
- SCCR: 22 kA
- Power Loss: 195 W at In
- Motor Cable: 10 m shielded at 4 kHz (C2/C3)
- Operating Temperature: -10 to +50 °C no derating; up to 60 °C with derating
- Storage Temperature: -25…+70 °C
- Humidity: 5…95%, no condensation
- Altitude: 1000 m no derating; 1% per 100 m above
- Protection: IP65
- Size (H×W×D): 521 x 320 x 335 mm
- Weight: 22.700 kg (50.044 lb)
- Terminal Torque: 1.2 to 1.5 N·m (Frame 4)
- Wire Size: 4 to 16 mm² (Frame 4)
- Clearance: 100 mm around drive; mount vertical ±10°
Installation Guide
- Mount the drive vertical. Tilt no more than ±10°.
- Leave 100 mm free space on all sides. This keeps airflow strong.
- Use 4 to 16 mm² wires on Frame 4 terminals.
- Tighten each terminal to 1.2 to 1.5 N·m.
- Keep the shielded motor cable under 10 m for C2/C3.
- Add a 27 Ω or higher brake resistor if you need braking.
- Seal all cable glands. Otherwise, the IP65 rating drops.
Setup and Service
- Set switching frequency from 2 to 16 kHz. Factory value is 4 kHz.
- Derate power above 4 kHz.
- Derate current by 1% per 100 m above 1000 m altitude.
- Plug in the VW3A1111 or VW3A1101 display for fast setup. Then copy settings to other drives.
- Clean the IP65 case with a water jet. Never soak the drive.
- Keep the drive dry. Stop condensation before power-up.
Compatibility Notes
- Runs induction motors and PM motors without a sensor.
- Ships with CANopen and Modbus Serial line.
- Add a module for EtherNet/IP, PROFIBUS DP V1, DeviceNet, EtherCAT, POWERLINK, or PROFINET. Thus one drive fits many networks.
- Fits GV2 breaker brackets, DIN rail plates, UL Type 1 kits, and 90-degree adapters.
Certifications
- UL 508C, UL61800-5-1, CSA 22.2 N274
- EN/IEC 61800-3 (C2/C3), EN/IEC 61800-5-1
- IEC 61800-5-2 up to SIL3, IEC 61508 SIL3, IEC 13849-1 PLe
- IEC 60721-3-3 (3C3/3S2), RCM, EAC, KC
Package Contents
- ATV320U55N4WS drive
- Installation manual NVE41289
- Safety sheet
- Quick start guide
Best Fit: Equipment and Applications
- Heavy conveyors: bulk handling and loading lines
- Mixers and agitators: food, chemical, and paint plants
- Pumps and fans: high-flow duty in wet rooms
- Packaging machines: cartoners and palletizers
- Wood and textile lines: dusty shops with washdown needs
FAQ
- Q: My 5.5 kW motor stalls on start. What should I check?
A: First check the motor current against the 14.3 A output rating. Then look at the acceleration ramp. A ramp that is too short pulls high current. Finally, confirm the motor wiring matches the supply voltage. - Q: The drive trips on overvoltage during fast stops. Why?
A: Fast stops push energy back to the drive. Add a 27 Ω or higher brake resistor. Or set a longer deceleration ramp. Both steps reduce the trip risk. - Q: Can I share one brake resistor across two drives?
A: No. Each drive needs its own resistor. Shared resistors can overheat and fail. Size each resistor for the load and duty cycle. Check manual NVE41289 for values. - Q: The enclosure shows water inside after washdown. What now?
A: Check the cable glands first. Loose glands let water in. Also inspect the cover gasket for cuts. Re-tighten glands after any cable change. Never aim a jet at the cover seam. - Q: How do I pick the right motor cable for a long run?
A: Use shielded cable. Keep the run under 10 m at 4 kHz. If you need more length, lower the switching frequency. Then test for noise on nearby sensors.