Product details
ATV320U22N4WS | Schneider Electric Altivar Machine ATV320 2.2 kW IP65 Drive with Disconnect
Say hello to the ATV320U22N4WS. It sits in the Altivar Machine ATV320 line from Schneider Electric. The drive powers 2.2 kW (3 HP) motors on 380 to 500 V three-phase mains. Its key feature is a Vario disconnect switch built into the front. So you get local lockout with no extra isolator. The IP65 shell keeps dust and spray out. A category C2 EMC filter is pre-installed. You also get strong torque, a 599 Hz range and SIL3/PLe safety.
Name Plate
- Brand: Schneider Electric
- Model: ATV320U22N4WS
- Series: Altivar Machine ATV320
- Type: Three-phase variable speed drive, wall mount, IP65, with disconnect switch
Power Core
- Motor power: 2.2 kW (3 HP) at 380 to 500 V three-phase
- Nominal output current: 5.5 A at 4 kHz
- Transient current: 8.3 A for 60 s (150% of In)
- Output frequency: 0.1 to 599 Hz
- Switching frequency: 2 to 16 kHz, 4 kHz preset; derate above 4 kHz
- Overload torque: up to 200% Tn over-torque and 170% Tn braking torque
- Rating: one rating only; no Normal Duty or Heavy Duty split
Line Feed
- Voltage: 380 to 500 V three-phase, -15%/+10%, 50/60 Hz
- Input current: 8.7 A at 380 V; 6.6 A at 500 V
- Apparent power: 5.7 kVA at 500 V maximum
- SCCR: 5 kA maximum
- Losses: 74 W at In and rated switching frequency
Control Brain
- Async motor: U/F ratio (2-point, 5-point, energy-saving, quadratic) and sensorless flux vector control
- PM motor: sensorless vector control
- Analog path: 10-bit resolution on the analog output
I/O Branches
- Analog inputs
- 1 x bipolar differential ±10 V
- 1 x 0 to 10 V
- 1 x 0 to 20 mA
- PTC probe support
- Digital inputs
- 4 x 24 V DC, sink/source, configurable
- 1 x PTC probe
- 1 x pulse, up to 20 kHz
- Digital output: 1 x 24 V DC sink/source, 100 mA maximum
- Analog output: 1 x 0 to 10 V or 0/4 to 20 mA, 10 bits
- Relay outputs
- 1 x NO/NC contact
- 1 x NO contact
- 3 A at 250 VAC resistive load
- Pulse output: 1 x 24 V, 32 kHz maximum, 0.1 A
- Safety inputs
- 1 x STO
- 4 x configurable for SS1, SLS, SMS and GDL
- STO reaches SIL3 and PLe
Brake Path
- Method: dynamic braking resistor
- Transistor: internal braking transistor on this size
- Minimum resistor: 54 Ω
- Note: add an outside resistor for fast stops or high inertia
Network Branches
- Built-in port
- 1 x RJ45
- CANopen
- Modbus Serial Line
- Expansion slot
- Modbus TCP and EtherNet/IP
- PROFIBUS DP V1
- DeviceNet
- EtherCAT
- POWERLINK
- PROFINET
- Cyber certificate: none published by the maker
Weather and Noise
- Protection: IP65
- Running temperature: -10 to +50 °C with no derating; up to 60 °C with derating
- Storage temperature: -25 to +70 °C
- Humidity: 5 to 95%, no condensation, no dripping water
- Height: no derating to 1000 m; 1% current loss per 100 m up to 3000 m
- EMC: built-in C2 filter; 10 m shielded motor cable at 4 kHz (C2 and C3)
- Ambient class: IEC 60721-3-3 class 3C3/3S2
Body Size
- Dimensions (H×W×D): 340 x 250 x 235 mm
- Weight: 8.100 kg (17.857 lb)
- Terminal torque: 1.4 N·m (Frame 3)
- Wire size: 2.5 to 6 mm² (Frame 3)
Where It Shines
- Small conveyors and feeders that need a local lockout point
- Pumps and fans on skids far from the main panel
- Mixers and stirrers in food or chemical rooms
- Packaging machines with spray cleaning near the drive
- Retrofit projects where a separate isolator costs time and money
- Wood and metal shops with dust on the floor
Mount and Wire
- Mount upright. A tilt of ±10° is fine.
- Leave 100 mm free space on all sides.
- Tighten power screws to 1.4 N·m.
- Use wire from 2.5 to 6 mm².
- Keep shielded motor cable at or under 10 m for C2 EMC.
- Fit a resistor of at least 54 Ω for braking duty.
- Cut current 1% per 100 m above 1000 m altitude.
Commission and Care
- Use the disconnect switch to isolate the unit for service.
- Set up the drive over the RJ45 port with Modbus or CANopen.
- Add the VW3A1111 or VW3A1101 terminal for local control.
- Copy settings to a spare drive to cut downtime.
- Stay at 4 kHz unless you check the derating curve.
Match and Fit
- Runs standard async motors and PM motors.
- Works on 380 to 500 V grids at 50 or 60 Hz.
- Pairs with GV2 breakers using the mounting bracket.
- Takes DIN rail plates and UL Type 1 kits.
- Adds one fieldbus module through the free slot.
Approvals
- UL 508C and UL 61800-5-1
- CSA 22.2 N274
- EN/IEC 61800-3 category C2/C3
- EN/IEC 61800-5-1
- IEC 61800-5-2 up to SIL3 and IEC 61508 SIL3
- ISO 13849-1 PLe
- IEC 60721-3-3 class 3C3/3S2
- RCM, EAC and KC
In the Box
- 1 x ATV320U22N4WS drive with Vario disconnect switch
- 1 x printed installation manual
- 1 x safety sheet
- Terminal parts as packed by Schneider Electric
- Display terminal and brake resistor sold apart
FAQ
What makes this size different from the 1.1 kW unit?
Two things. It gives more current at 5.5 A. And it has an internal braking transistor, so brake wiring is simpler.
Does the switch cut all three phases?
Yes. The Vario switch isolates the mains feed at the case front. You can padlock it for safe service work.
Will the filter handle a long motor run?
Only to a point. Keep shielded cable at or under 10 m at 4 kHz. Add a reactor or filter for longer runs.
How warm will the case get?
It sheds about 74 W at full load. Keep the 100 mm air gap and stay under 50 °C for full current.
Can it drive a PM motor from a lift?
Yes, it supports sensorless PM control. For holding duty, add a mechanical brake. Do not rely on the drive alone.
What trips most units in the field?
Overheat from tight mounting. Crews stack drives with no gap. Keep 100 mm clear and the fault rate drops fast.
















There are no reviews yet.