Product details
ATV320U30N4WS | Schneider Electric Altivar Machine ATV320 3 kW IP65 Drive with Disconnect
Meet the ATV320U30N4WS. It is part of the Altivar Machine ATV320 series by Schneider Electric. This drive moves 3 kW (3 HP) motors on 380 to 500 V three-phase lines. A Vario disconnect switch is fixed to the front. That gives you a lockout point right at the machine. The IP65 body blocks dust and spray. A category C2 EMC filter is already fitted. Firm torque, a 599 Hz ceiling and SIL3/PLe safety round it out.
Name Plate
- Brand: Schneider Electric
- Model: ATV320U30N4WS
- Series: Altivar Machine ATV320
- Type: Three-phase variable speed drive, wall mount, IP65, with disconnect switch
Power Core
- Motor power: 3 kW (3 HP) at 380 to 500 V three-phase
- Nominal output current: 7.1 A at 4 kHz
- Transient current: 10.7 A for 60 s (150% of In)
- Output frequency: 0.1 to 599 Hz
- Switching frequency: 2 to 16 kHz, 4 kHz preset; derate above 4 kHz
- Overload torque: up to 200% Tn over-torque and 170% Tn braking torque
- Rating: one rating only; no Normal Duty or Heavy Duty split
Line Feed
- Voltage: 380 to 500 V three-phase, -15%/+10%, 50/60 Hz
- Input current: 11.1 A at 380 V; 8.4 A at 500 V
- Apparent power: 7.3 kVA at 500 V maximum
- SCCR: 5 kA maximum
- Losses: 93 W at In and rated switching frequency
Control Brain
- Async motor: U/F ratio (2-point, 5-point, energy-saving, quadratic) and sensorless flux vector control
- PM motor: sensorless vector control
- Analog path: 10-bit resolution on the analog output
I/O Branches
- Analog inputs
- 1 x bipolar differential ±10 V
- 1 x 0 to 10 V
- 1 x 0 to 20 mA
- PTC probe support
- Digital inputs
- 4 x 24 V DC, sink/source, configurable
- 1 x PTC probe
- 1 x pulse, up to 20 kHz
- Digital output: 1 x 24 V DC sink/source, 100 mA maximum
- Analog output: 1 x 0 to 10 V or 0/4 to 20 mA, 10 bits
- Relay outputs
- 1 x NO/NC contact
- 1 x NO contact
- 3 A at 250 VAC resistive load
- Pulse output: 1 x 24 V, 32 kHz maximum, 0.1 A
- Safety inputs
- 1 x STO
- 4 x configurable for SS1, SLS, SMS and GDL
- STO reaches SIL3 and PLe
Brake Path
- Method: dynamic braking resistor
- Transistor: internal braking transistor on this size
- Minimum resistor: 54 Ω
- Note: add an outside resistor for fast stops or high inertia
Network Branches
- Built-in port
- 1 x RJ45
- CANopen
- Modbus Serial Line
- Expansion slot
- Modbus TCP and EtherNet/IP
- PROFIBUS DP V1
- DeviceNet
- EtherCAT
- POWERLINK
- PROFINET
- Cyber certificate: none published by the maker
Weather and Noise
- Protection: IP65
- Running temperature: -10 to +50 °C with no derating; up to 60 °C with derating
- Storage temperature: -25 to +70 °C
- Humidity: 5 to 95%, no condensation, no dripping water
- Height: no derating to 1000 m; 1% current loss per 100 m up to 3000 m
- EMC: built-in C2 filter; 10 m shielded motor cable at 4 kHz (C2 and C3)
- Ambient class: IEC 60721-3-3 class 3C3/3S2
Body Size
- Dimensions (H×W×D): 340 x 250 x 235 mm
- Weight: 8.100 kg (17.857 lb)
- Terminal torque: 1.4 N·m (Frame 3)
- Wire size: 2.5 to 6 mm² (Frame 3)
Where It Shines
- Conveyors and transfer units that need a local lockout
- Fans and blowers on rooftop or skid mounts
- Pumps in water, food and HVAC loops
- Small mixers and stirrers with hard starts
- Packaging and labeling cells with spray cleaning
- Retrofit jobs where a separate isolator costs time and money
Mount and Wire
- Mount upright. A tilt of ±10° is fine.
- Leave 100 mm free space on all sides.
- Tighten power screws to 1.4 N·m.
- Use wire from 2.5 to 6 mm².
- Keep shielded motor cable at or under 10 m for C2 EMC.
- Fit a resistor of at least 54 Ω for braking duty.
- Cut current 1% per 100 m above 1000 m altitude.
Commission and Care
- Use the disconnect switch to isolate the unit for service.
- Set up the drive over the RJ45 port with Modbus or CANopen.
- Add the VW3A1111 or VW3A1101 terminal for local control.
- Copy settings to a spare drive to cut downtime.
- Stay at 4 kHz unless you check the derating curve.
Match and Fit
- Runs standard async motors and PM motors.
- Works on 380 to 500 V grids at 50 or 60 Hz.
- Pairs with GV2 breakers using the mounting bracket.
- Takes DIN rail plates and UL Type 1 kits.
- Adds one fieldbus module through the free slot.
Approvals
- UL 508C and UL 61800-5-1
- CSA 22.2 N274
- EN/IEC 61800-3 category C2/C3
- EN/IEC 61800-5-1
- IEC 61800-5-2 up to SIL3 and IEC 61508 SIL3
- ISO 13849-1 PLe
- IEC 60721-3-3 class 3C3/3S2
- RCM, EAC and KC
In the Box
- 1 x ATV320U30N4WS drive with Vario disconnect switch
- 1 x printed installation manual
- 1 x safety sheet
- Terminal parts as packed by Schneider Electric
- Display terminal and brake resistor sold apart
FAQ
How is the 3 kW unit different from the 2.2 kW one?
Same shell and switch, more output. Current rises to 7.1 A. That covers bigger pumps, fans and conveyors on the same footprint.
Is the switch rated for motor load?
Yes. It is a motor disconnect, not just a control switch. You can padlock it in the off state during service work.
Why does the input current look high at 380 V?
Lower volts mean more amps for the same power. At 380 V the drive draws up to 11.1 A. Size the breaker for that value.
Can I mount it sideways?
Only within ±10° of upright. A flat or upside-down mount blocks airflow. Heat then builds and the drive trips.
Does the internal brake transistor save me wiring?
Yes. On this size the transistor is inside. You only wire the resistor. Choose one of at least 54 Ω for fast stops.
What do crews get wrong on first install?
Two things. They skip the 100 mm air gap. And they run motor cable past 10 m. Both cause faults that are easy to avoid.