Over 50,000 hot-selling automation module components.

ATV320U15N4WS Schneider Altivar 320 1.5 kW Drive STO CANopen

0 Reviews
In stock
  • 100% genuine products in stock with fast delivery.
  • 30-day return policy for quality assurance.
  • 12-month warranty for peace of mind.
SKU: ATV320U15N4WS

Product details

Product Overview

  • ATV320U15N4WS is a Schneider Electric Altivar Machine drive.
  • Moreover, it delivers 1.5 kW (2 HP) for three-phase 380…500 V supplies.
  • The IP65 wall-mount enclosure also includes a Vario disconnect switch.
  • A category C2 EMC filter is built in. Therefore, no extra filter is needed.
  • For example, the drive suits conveyors, packaging machines, and material handling.
  • In addition, it controls asynchronous motors and synchronous PM motors in open loop.
  • STO up to SIL3/PLe supports safe machine stop. Thus, no extra safety hardware is needed.

Key Technical Data

  • Brand: Schneider Electric
  • Model: ATV320U15N4WS
  • Series: Altivar Machine ATV320
  • Module type: IP65 wall-mount variable speed drive
  • Motor power: 1.5 kW (2 HP) at 380…500 V three-phase
  • Output frequency range: 0.1 to 599 Hz
  • Nominal output current In: 4.1 A at 4 kHz switching frequency
  • Transient output current: 6.2 A for up to 60 s (150% of In)
  • Overload torque: up to 200% Tn over-torque and 170% Tn braking torque in open loop
  • Switching frequency: 2 to 16 kHz programmable; still factory set at 4 kHz
  • Resolution: analog output 10 bits; pulse input up to 20 kHz; pulse output up to 32 kHz
  • Control accuracy: stable speed hold via sensorless flux vector control
  • Analog inputs: 1 bipolar differential ±10 V, 1 voltage 0…10 V, and 1 current 0-20 mA
  • Digital inputs: 6 total; 4 configurable 24 V DC sink/source, 1 PTC probe, and 1 pulse input
  • Analog output: 1 channel, 0…10 V or 0/4-20 mA
  • Digital output: 1 configurable 24 V DC sink/source, max 100 mA
  • Relay outputs: 1 NO/NC contact plus 1 NO contact, 3 A at 250 VAC resistive load
  • Pulse output: 24 V, max 32 kHz, 0.1 A
  • Safety inputs: 1 STO input plus 4 configurable safety inputs (SS1, SLS, SMS, GDL)
  • Braking: external resistor connection; therefore minimum value is 54 Ω
  • Supply voltage: 380…500 V three-phase, -15%/+10%, 50/60 Hz
  • Maximum input current: 6.4 A at 380 V; meanwhile 4.9 A at 500 V
  • Apparent power: 4.2 kVA at 500 V maximum
  • SCCR: 5 kA maximum
  • Power dissipation: 56 W at In and rated switching frequency
  • Temperature range: -10 to +50 °C without derating; however up to 60 °C with derating
  • Storage temperature: -25 to +70 °C
  • Humidity tolerance: 5…95%, no condensation, and no dripping water
  • Altitude: no derating to 1000 m; then derate 1% per 100 m up to 3000 m
  • Noise immunity: the integrated C2 EMC filter limits conducted emissions
  • Shielded motor cable: 10 m maximum at 4 kHz, category C2 or C3
  • Protection rating: IP65
  • Dimensions (H×W×D): 340 x 250 x 200 mm
  • Weight: 6.400 kg (14.109 lb)

Installation Guide

  • First, mount the drive vertically. Keep tilt within ±10°.
  • Then leave 100 mm clearance around the enclosure for airflow.
  • Tighten power terminals to 1.4 N·m and control terminals to 0.6 N·m.
  • Also use wire cross-sections from 2.5 to 6 mm² (Frame 2).
  • Keep shielded motor cables within 10 m at 4 kHz. Otherwise noise rises.
  • Connect the STO input for safe torque off. Still follow SIL3 wiring rules.
  • Add an external braking resistor if the load needs fast stops. In that case the minimum value is 54 Ω.

Setup and Maintenance

  • Use the RJ45 port for CANopen or Modbus Serial line setup.
  • Moreover, add a communication module in the single expansion slot when needed.
  • For faster tuning, use the optional VW3A1111 or VW3A1101 display terminal.
  • First set motor data with the drive wizard. Then run auto-tune for open-loop vector control.
  • Check fan paths and terminal torque at each service interval. As a result, trips drop.
  • The IP65 enclosure allows washdown-area mounting. Therefore panel cleaning work falls.

Compatibility Notes

  • It works with asynchronous motors using U/F or sensorless flux vector control.
  • It also works with synchronous PM motors using sensorless vector control.
  • Built-in protocols are CANopen and Modbus Serial line.
  • In addition, optional modules add Modbus TCP/EtherNet/IP, PROFIBUS DP V1, DeviceNet, EtherCAT, POWERLINK, or PROFINET.
  • Accessories include UL Type 1 kits, DIN rail plates, a GV2 breaker bracket, and a 90-degree control module adapter.

Certifications

  • UL 508C and UL 61800-5-1
  • CSA 22.2 N274
  • EN/IEC 61800-3 category C2/C3
  • EN/IEC 61800-5-1
  • IEC 61800-5-2 up to SIL3 and IEC 61508 SIL3
  • IEC 13849-1 PLe
  • IEC 60721-3-3 class 3C3/3S2
  • RCM, EAC, KC
  • However, the manufacturer publishes no product-level cybersecurity certificate.

Packing List

  • 1 x ATV320U15N4WS drive with Vario disconnect switch
  • 1 x installation manual (NVE41289 reference)
  • 1 x safety information sheet
  • Terminal labels and cable clamp parts as shipped by Schneider Electric
  • Optional display terminal and communication module ship separately. Thus, order them apart.

FAQ

  • Q: Can this drive run a 1.5 kW motor at 400 V?
    Yes. The 380…500 V three-phase input matches standard 400 V motors at 1.5 kW.
  • Q: Does the drive need an external EMC filter?
    No. A category C2 filter is integrated. Therefore keep motor cables shielded and short.
  • Q: What is the minimum braking resistor value?
    54 Ω. Moreover, the installation manual lists this limit for safe braking.
  • Q: Can I mount the drive outdoors?
    The IP65 rating blocks dust and water jets. Still add a sun shield and stay within the temperature range.
  • Q: How do I reach SIL3 safety?
    Wire the STO input per the manual. Thus the safety functions support SIL3 and PLe.
  • Q: Which protocol works out of the box?
    CANopen and Modbus Serial line run on the built-in RJ45 port. Other protocols need an optional module.
  • Q: From experience, what causes nuisance trips at high switching frequency?
    High carrier frequency raises heat. Therefore derate above 4 kHz and check enclosure airflow first.
  • Q: From experience, why does the drive show an overcurrent fault at start?
    Long motor cables or a stiff load cause this. In practice, shorten the cable, check the ramp time, and verify motor data.
  • Q: From experience, how do I cut setup time?
    First load the motor nameplate values. Then run auto-tune and save the configuration to the display terminal.

Specifications

  • BrandAllen-Bradley
  • Part Number22A-B012F104
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “ATV320U15N4WS Schneider Altivar 320 1.5 kW Drive STO CANopen”

Your email address will not be published. Required fields are marked *

Back to Top