ATV320U15N4W | Schneider Electric Altivar Machine ATV320 1.5 kW IP66 Drive
This is the ATV320U15N4W. It comes from the Altivar Machine ATV320 line by Schneider Electric. The drive pushes 1.5 kW (2 HP) from a 380 to 500 V three-phase feed. Its IP66 shell is sealed for harsh floors. A category C2 EMC filter sits inside. So you skip extra cabinet parts and save build time. Strong torque, a 599 Hz ceiling and SIL3/PLe safety all live in one compact body.
Name Plate
- Brand: Schneider Electric
- Model: ATV320U15N4W
- Series: Altivar Machine ATV320
- Type: Three-phase variable speed drive, wall mount, IP66
Power Core
- Motor power: 1.5 kW (2 HP) at 380 to 500 V three-phase
- Nominal output current: 4.1 A at 4 kHz
- Transient current: 6.2 A for 60 s (150% of In)
- Output frequency: 0.1 to 599 Hz
- Switching frequency: 2 to 16 kHz, 4 kHz preset; derate above 4 kHz
- Overload torque: up to 200% Tn over-torque and 170% Tn braking torque
- Rating: one rating only; no Normal Duty or Heavy Duty split
Line Feed
- Voltage: 380 to 500 V three-phase, -15%/+10%, 50/60 Hz
- Input current: 6.4 A at 380 V; 4.9 A at 500 V
- Apparent power: 4.2 kVA at 500 V maximum
- SCCR: 5 kA maximum
- Losses: 56 W at In and rated switching frequency
Control Brain
- Async motor: U/F ratio (2-point, 5-point, energy-saving, quadratic) and sensorless flux vector control
- PM motor: sensorless vector control
- Analog path: 10-bit resolution on the analog output
I/O Branches
- Analog inputs
- 1 x bipolar differential ±10 V
- 1 x 0 to 10 V
- 1 x 0 to 20 mA
- PTC probe support
- Digital inputs
- 4 x 24 V DC, sink/source, configurable
- 1 x PTC probe
- 1 x pulse, up to 20 kHz
- Digital output: 1 x 24 V DC sink/source, 100 mA maximum
- Analog output: 1 x 0 to 10 V or 0/4 to 20 mA, 10 bits
- Relay outputs
- 1 x NO/NC contact
- 1 x NO contact
- 3 A at 250 VAC resistive load
- Pulse output: 1 x 24 V, 32 kHz maximum, 0.1 A
- Safety inputs
- 1 x STO
- 4 x configurable for SS1, SLS, SMS and GDL
- STO reaches SIL3 and PLe
Brake Path
- Method: external dynamic braking resistor
- Minimum value: 54 Ω
- Note: this power size needs an outside resistor for fast stops
Network Branches
- Built-in port
- 1 x RJ45
- CANopen
- Modbus Serial Line
- Expansion slot
- Modbus TCP and EtherNet/IP
- PROFIBUS DP V1
- DeviceNet
- EtherCAT
- POWERLINK
- PROFINET
- Cyber certificate: none published by the maker
Weather and Noise
- Protection: IP66
- Running temperature: -10 to +50 °C with no derating; up to 60 °C with derating
- Storage temperature: -25 to +70 °C
- Humidity: 5 to 95%, no condensation, no dripping water
- Height: no derating to 1000 m; 1% current loss per 100 m up to 3000 m
- EMC: built-in C2 filter; 10 m shielded motor cable at 4 kHz (C2 and C3)
- Ambient class: IEC 60721-3-3 class 3C3/3S2
Body Size
- Dimensions (H×W×D): 340 x 250 x 200 mm
- Weight: 6.000 kg (13.227 lb)
- Terminal torque: 1.4 N·m power, 0.6 N·m control (Frame 2)
- Wire size: 2.5 to 6 mm² (Frame 2)
Where It Shines
- Conveyors and sorters that carry steady loads at low speed
- Packaging and filling lines with tight space and washdown risk
- Pumps and fans in food, water and HVAC sites
- Mixers and agitators that need strong starting torque
- Wood, stone and metal shops with dusty air
- Outdoor skids where a sealed box replaces a full cabinet
Mount and Wire
- Mount upright. A tilt of ±10° is fine.
- Leave 100 mm free space on all sides.
- Tighten power screws to 1.4 N·m and control screws to 0.6 N·m.
- Use wire from 2.5 to 6 mm².
- Keep shielded motor cable at or under 10 m for C2 EMC.
- Fit a resistor of at least 54 Ω for braking duty.
- Cut current 1% per 100 m above 1000 m altitude.
Commission and Care
- Set up the unit over the RJ45 port with Modbus or CANopen.
- Add the VW3A1111 or VW3A1101 terminal for local control.
- Copy settings to a spare drive to cut downtime.
- The sealed housing needs no filter swap.
- Stay at 4 kHz unless you check the derating curve.
Match and Fit
- Runs standard async motors and PM motors.
- Works on 380 to 500 V grids at 50 or 60 Hz.
- Pairs with GV2 breakers using the mounting bracket.
- Takes DIN rail plates and UL Type 1 kits.
- Adds one fieldbus module through the free slot.
Approvals
- UL 508C and UL 61800-5-1
- CSA 22.2 N274
- EN/IEC 61800-3 category C2/C3
- EN/IEC 61800-5-1
- IEC 61800-5-2 up to SIL3 and IEC 61508 SIL3
- ISO 13849-1 PLe
- IEC 60721-3-3 class 3C3/3S2
- RCM, EAC and KC
In the Box
- 1 x ATV320U15N4W drive
- 1 x printed installation manual
- 1 x safety sheet
- Terminal parts as packed by Schneider Electric
- Display terminal and brake resistor sold apart
FAQ
Which machines pair well with 1.5 kW?
Mid-size loads fit this size. Think mixers, agitators, medium conveyors and pump sets. Check that motor current stays near 4.1 A.
Can it start a heavy load?
Yes. You get up to 200% Tn over-torque for short bursts. The 150% current boost lasts up to 60 s.
How short must the motor cable be?
Keep shielded cable at or under 10 m at 4 kHz. This holds the C2 EMC level. Longer runs may need extra filtering.
What if I run it above 50 °C?
The drive still works up to 60 °C. But you must lower the output current. Follow the derating curve before you raise the set point.
Why does the factory set 4 kHz?
It balances low motor noise and low heat. Higher values cut acoustic noise but add losses. Check the curve before you change it.
How do I avoid a long stop after a fault?
Save the setup on a terminal or over the bus. Load the same file into a spare unit. This skips manual re-entry and shortens the halt.
















There are no reviews yet.