Product details
XNX-AMSV-RNCB1 Universal Transmitter by Honeywell
Reliable gas detection for demanding industrial environments. The XNX-AMSV-RNCB1 offers HART over 4-20mA, 3 fault/alarm relays, and a rugged painted 316SS enclosure. It comes with an MPD catalytic sensor (0-100% LEL) for combustible gas monitoring.
Product Overview
- Manufacturer: Honeywell
- Model: XNX-AMSV-RNCB1
- Type: Universal Transmitter with HART over 4-20mA output
- Approval: ATEX/IECEx/INMETRO (Zone 1, 2, 21, 22)
- Enclosure: Painted 316 Stainless Steel, 4 x M25 cable entries
- Sensor: MPD catalytic bead, 0-100% LEL (combustible gases)
- Output: HART® digital communication over analog 4-20mA
- Relays: 3 programmable fault/alarm relays
- Weight: 5 kg
Technical Data
- Measurement Range: 0–100% LEL (combustible gases)
- Frequency Response: T90 < 30 seconds (typical)
- Sensitivity: High sensitivity to methane, propane, and other hydrocarbons
- Linearity: ±5% of full scale (typical)
- Resolution: 1% LEL (digital display)
- Temperature Range: -40°C to +65°C (operation)
- Environmental Tolerance: IP66/67, humidity 0–95% RH (non-condensing)
- Interference Immunity: Excellent EMI/RFI rejection (EN 50270)
Installation Guide
- Use M25 rated cable glands (4 entries provided).
- Mount on a flat vertical surface, sensor pointing downward.
- Ensure adequate clearance for sensor replacement.
- Use shielded twisted-pair cable for 4-20mA loop.
- Ground the enclosure to minimize electrical noise.
- Follow ATEX/IECEx installation drawings (supplied in manual).
Commissioning & Maintenance
- Auto-calibration via magnetic switches (no need to open enclosure).
- One-person calibration with HART communicator or handheld tool.
- Diagnostic self-test on power-up and every 24 hours.
- Sensor replacement takes less than 5 minutes.
- Clear LED status indicators (green/amber/red).
- Remote access to fault logs via HART.
Compatibility
- Gas Types: Methane, propane, butane, hydrogen, and most hydrocarbons.
- Systems: Any PLC, DCS, or SCADA with 4-20mA input.
- HART: Compatible with HART 5, 6, and 7 handhelds or multiplexers.
- Works with MPD, Sensepoint, and Model 705 HT/PPM sensors (personality V).
Certifications
- ATEX: II 2G Ex db IIC T4 Gb (gas) / II 2D Ex tb IIIC T135°C Db (dust)
- IECEx: Ex db IIC T4 Gb / Ex tb IIIC T135°C Db
- INMETRO: Approved for Brazilian hazardous areas.
- Marine: DNV GL type approved (optional).
Package Contents
- XNX-AMSV-RNCB1 transmitter assembly
- MPD catalytic sensor (0-100% LEL) pre-installed
- Mounting bracket kit with stainless steel screws
- Cable glands (4 x M25, stainless steel)
- Quick start guide and CD manual
- Calibration test certificate
Warranty & Shipping
- Warranty: 12 months against manufacturing defects.
- Dispatch: 12–24 hours after order confirmation.
- Carriers: FedEx, UPS, or DHL (express shipping).
Expert Review
“The XNX-AMSV-RNCB1 is a workhorse for oil & gas. The painted 316SS withstands offshore corrosion. HART over 4-20mA simplifies troubleshooting. MPD sensor responds fast to methane leaks. Relays offer flexible alarm logic. A reliable choice for SIL 2 environments.” – Senior Instrument Engineer
Manager’s Insight
“We deploy this transmitter across 15 plants. Its magnetic interface saves us 40% calibration time. The 4 x M25 entries reduce junction box costs. With ATEX and IECEx, we comply globally. The 12-hour dispatch from PowergearX keeps our projects on schedule.” – Plant Operations Manager
Suitable Devices & Applications
- Devices: PLCs, DCS, SCADA, HART handhelds, gas control panels.
- Applications: Offshore platforms, refineries, chemical plants, gas storage, wastewater treatment, and paint booths.
- Ideal for LEL monitoring in Zone 1, 2, 21, and 22 areas.
Frequently Asked Questions
Q: Does this unit include a sensor?
A: Yes. It comes with the MPD catalytic sensor 0-100% LEL pre-installed.
Q: Can I use this with a non-HART system?
A: Yes. The 4-20mA analog output works with any standard input.
Q: What is the temperature limit for the sensor?
A: The sensor operates from -40°C to +65°C.
Q: Is the relay option programmable?
A: Yes. All 3 relays are fully programmable for alarm or fault conditions.
Q: Do I need extra cable glands?
A: No. Four M25 stainless steel glands are included in the package.
Q: How do I calibrate without opening the housing?
A: Use the magnetic wand (included) to navigate the menu through the glass window.
Q: Does it support MODBUS?
A: No. It uses HART protocol over 4-20mA. For MODBUS, check other XNX variants.
Selection Guide
- For methane detection in pipelines → Choose this model (0-100% LEL).
- For toxic gas (ppm) → Select the XNX version with electrochemical sensor.
- For extreme cold climates → The -40°C rating fits Arctic applications.
- For SIL 2 requirement → This transmitter meets SIL 2 capability (documented).
- For offshore use → Painted 316SS and IP66/67 are ideal.
- If you need local HART display → Choose variant with “H” option (not this one).
Contact & Ordering
Sales & Technical Support
Email: sales@powergearx.com
WhatsApp: +86 18030005825
Original Source: https://www.powergearx.com/
Copyright © 2026 Powergear X Automation Limited. All rights reserved.















There are no reviews yet.