XNX-AMSV-NNIV1 – Honeywell XNX Gas Detector

Reliable, ATEX-approved universal transmitter with HART® over 4-20mA. Designed for demanding industrial environments. Delivers precise methane detection.

Product Description

  • XNX-AMSV-NNIV1 is a universal transmitter by Honeywell.
  • It supports HART® communication over a 4-20mA output loop.
  • This model includes an MPD IR sensor for methane (0-100%LEL / 0-5%v/v).
  • Housed in painted 316 stainless steel, it withstands harsh conditions.
  • Entry type: 5 x M25 cable glands for flexible wiring.
  • Personality: mV version, compatible with MPD, Sensepoint, Model 705 HT, and PPM sensors.
  • Approval: ATEX/IECEx/INMETRO for global hazardous area use.

Technical Specifications

  • Brand: Honeywell
  • Model: XNX-AMSV-NNIV1
  • Product Type: XNX Universal Transmitter
  • Output: 4-20mA with HART®
  • Measurement Range: 0-100%LEL (or 0-5%Vol.) Methane
  • Sensor Type: MPD IR hydrocarbon (Methane)
  • Frequency Response: Fast T90 < 10 seconds
  • Sensitivity: Excellent low-level detection
  • Linearity: ±2% of full scale
  • Resolution: 0.1%LEL
  • Operating Temperature: -20°C to +60°C
  • Environmental Resistance: IP66/IP67 rated enclosure
  • Immunity: High resistance to RFI/EMI interference
  • Material: 316 stainless steel (painted)
  • Weight: 6.8 kg

Installation & Mounting

  • Use 5 x M25 cable entries for secure connections.
  • Wall or pole mount with included brackets.
  • Ensure sensor faces the potential gas source.
  • Follow ATEX wiring guidelines for safe installation.
  • Calibration required after installation.

Commissioning & Maintenance

  • Simple zero and span calibration via HART®.
  • Magnetic switch for non-intrusive adjustment.
  • Diagnostic LEDs indicate sensor status.
  • Sensor replacement takes less than 5 minutes.
  • Routine bump test recommended every 6 months.

Compatibility

  • Works with MPD, Sensepoint, and Model 705 HT sensors.
  • Supports PPM and HT sensor types.
  • Integrates with any 4-20mA input control system.
  • HART® compatible with handheld communicators.

Certifications

  • ATEX – Zone 1 & 2 hazardous areas
  • IECEx – International approval
  • INMETRO – Brazilian certification
  • CE marked for European compliance

What’s in the Box

  • XNX-AMSV-NNIV1 transmitter unit
  • MPD IR methane sensor (pre-installed)
  • Mounting bracket kit
  • Cable glands (5 x M25)
  • User manual and quick start guide
  • Calibration certificate

Warranty & Shipping

  • 12-month warranty against manufacturing defects.
  • Shipping within 12-24 hours of order confirmation.
  • Express delivery via FedEx, UPS, or DHL.
  • Tracking number provided immediately.

Expert Review – Manager’s Insight

“The XNX-AMSV-NNIV1 sets a benchmark for reliable methane detection. Its robust 316SS housing and ATEX approval make it ideal for offshore and petrochemical plants. The HART® integration simplifies troubleshooting, while the mV personality ensures compatibility with legacy sensors. A truly versatile transmitter.” – Senior Product Manager, Powergear X

Applications & Suitable Equipment

  • Oil and gas refineries
  • Chemical processing plants
  • Wastewater treatment facilities
  • Mining and tunnel monitoring
  • Pharmaceutical manufacturing
  • Used with control panels, PLCs, and DCS systems.

Frequently Asked Questions (FAQ)

  • Can I use this with a non-HART system?
    Yes, the 4-20mA analog output works without HART.
  • How often should I calibrate?
    Every 3 to 6 months, depending on the environment.
  • Is the sensor field-replaceable?
    Yes, you can swap it quickly without tools.
  • What is the maximum cable length?
    Up to 1000 meters with proper shielding.
  • Does it work in high humidity?
    Yes, IP66/IP67 protects against moisture.
  • Which gas does it detect?
    Specifically methane (0-100%LEL / 0-5%v/v).
  • Can I use it for other hydrocarbons?
    Only with a different MPD sensor head.

Experience & Selection Guide

  • For outdoor installations, choose the 316SS option for corrosion resistance.
  • If you need remote monitoring, use the HART® digital signal.
  • For fast response, position the sensor close to potential leak points.
  • Always verify the gas type and range before ordering.
  • Contact our support for custom sensor configurations.

Ordering & Contact

For bulk orders or technical questions, reach us at:
sales@powergearx.com
+86 18030005825 (WhatsApp)

Copyright © 2026 Powergear X Automation Limited. All rights reserved.

Original Source: https://www.powergearx.com/

Specifications

  • BrandHoneywell
  • Part NumberXNX-AMSV-NNIV1
  • ConditionOriginal Brand New

Customers Reviews

There are no reviews yet.

Be the first to review “XNX-AMSV-NNIV1 | Honeywell XNX Gas Detector | ATEX HART Transmitter”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart