Product details
Product Brief
- TM200HSC206DT belongs to the Modicon M238 logic controller series.
- This counter module offers 4 discrete outputs and 12 discrete inputs.
- It supports high-speed counting up to 60 kHz with 31‑bit + sign resolution.
- Designed for precise frequency, period, and axis‑following applications.
Key Features at a Glance
- High‑speed counting: 60 kHz max – handles incremental encoders and fast sensors.
- 8 configurable counting modes – up/down, frequency meter, period measurement, and more.
- Robust I/O – 12 inputs (type 1) + 4 outputs (0.5 A per channel).
- Built‑in protection – short‑circuit and overload with auto‑reset.
- Isolation 1500 V – between channels and internal logic for safety.
- Supports 2‑ and 3‑wire sensors as well as incremental encoders (15‑30 V source).
Technical Specifications
- Brand: Schneider Electric
- Model: TM200HSC206DT
- Series: Modicon M238
- Module type: High‑speed counter / application specific I/O
- Counting frequency: 60 kHz
- Resolution: 31 bits + sign
- Cycle time: 1 ms
- Discrete inputs: 12 (24 V DC, positive logic sink)
- Discrete outputs: 4 (24 V DC, 0.5 A, positive logic source)
- Input voltage range: 19.2 … 30 V DC
- State 1 guaranteed: 15‑30 V @ 5 mA
- State 0 guaranteed: ≤5 V @ ≤0.5 mA
- Output load: 2 A per module / 0.5 A per output
- Response time: ≤200 µs (energisation / de‑energisation)
- Leakage current: 0.1 mA max (state 0)
- Voltage drop: <3 V (state 1)
- Overload trip: 0.5 … 1.5 A with auto‑reset
- Load inductance: L = 0.5 / I²F
- Load capacitance: 50 µF
- Temperature range (ambient): 0 … +55 °C (operation)
- Environmental tolerance: IP20, resistant to vibration and humidity
- Immunity / EMC: meets EN/IEC 61131‑2 industrial standards
- Power consumption: ≤100 mA @ 24 V internal, ≤2 A @ 24 V external
- Mounting: 35 mm symmetrical DIN rail
- Wiring: 2 screw terminal blocks, shielded cable recommended
Installation & Commissioning
- DIN rail mount: snap‑on 35 mm rail – no tools required.
- Wiring: use shielded cables for encoder inputs to reduce noise.
- Configuration: set counting modes via software (8 modes).
- Fallback: each channel holds last value or preset (0/1).
- Diagnostics: local LED display block for quick status check.
- Maintenance: auto‑reset protection reduces downtime.
Compatibility & Certifications
- Compatible with: Modicon M238 base (up to 3 counter modules).
- Encoders: incremental signals with 15‑30 V source outputs.
- Sensors: 2‑wire and 3‑wire DC (24 V) sensors.
- Standards: EN/IEC 61131‑2 type 1 inputs.
- Isolation: 1500 V for 1 minute (channel‑to‑logic).
- Certifications: CE, UL, CSA (industrial control equipment).
Package Contents
- 1 × TM200HSC206DT counter module
- 2 × screw terminal blocks (pre‑installed)
- Quick start guide (multilingual)
- Warranty card (12 months)
Shipping & Delivery
- Dispatch within 12‑24 hours after order confirmation.
- Carriers: FedEx, UPS, DHL – tracked & insured.
- Global delivery typically 3‑7 business days.
Expert Review – Manager’s Insight
- “The TM200HSC206DT excels in high‑speed motion control. Its 60 kHz count rate and 1 ms cycle time make it ideal for synchronised axes.”
- “Built‑in auto‑reset protection and fallback logic reduce maintenance efforts in harsh factory floors.”
- “We recommend pairing it with incremental encoders for precise speed or position feedback.”
- “For new installations, the 35 mm DIN rail and screw terminals simplify panel integration.”
Typical Applications
- Packaging machines – high‑speed counting and batch control
- Conveyor systems – axis following and frequency monitoring
- Textile machinery – period measurement for tension control
- Automated test equipment – frequency generator and pulse capture
- Material handling – downcounting for position tracking
Frequently Asked Questions (FAQ)
- What is the maximum counting frequency?
60 kHz. It supports high‑speed incremental encoders and fast sensors. - How many modules can I install on one base?
Up to 3 counter modules per TM238 base. - Can I use this with NPN sensors?
No. It accepts positive logic (sink) inputs. Use PNP or source‑type sensors. - What happens if an output shorts?
The module automatically resets after the fault clears. No manual fuse replacement. - Is the module isolated from the logic side?
Yes. 1500 V isolation for 1 minute ensures safety. - What is the default fallback state?
Each channel can hold its last value or be preset to 0/1. Faulty channels default to 0. - Which encoders are compatible?
Incremental encoders with 15‑30 V source (push‑pull) outputs. Shielded cable required. - Can I measure frequency and period simultaneously?
Yes. Use configurable modes to switch between frequency, period, up/down, etc.
Purchasing Guide – What to Consider
- Check your encoder type: this module works with 15‑30 V source outputs only.
- Ensure your PLC base has free slots (max 3 counter modules).
- For harsh environments, verify the temperature range (0‑55 °C) and IP20 rating.
- Consider external power: the module draws up to 2 A @ 24 V DC for outputs.
- Use shielded cables to maintain signal integrity at 60 kHz.
Contact & Support
- For technical inquiries or bulk orders, email us at sales@powergearx.com
- Call or WhatsApp: +86 18030005825
- Our team responds within 2 business hours.
Copyright © 2026 Powergear X Automation Limited. All rights reserved.