Product details
MDX91A-1770-503-4-T00 | SEW-EURODRIVE MOVIDRIVE Modular Multi-Axis Inverter
MDX91A-1770-503-4-T00 is a book-style multi-axis inverter from the SEW-EURODRIVE MOVIDRIVE modular system. It delivers 177.0 A rated output at 4 kHz PWM. It connects directly to a 3~AC 380-500 V line. Frame size 7 supports 4-quadrant operation. The unit fits control-cabinet multi-axis applications that need high current in a compact footprint.
Technical Data
- Brand: SEW-EURODRIVE
- Model: MDX91A-1770-503-4-T00
- Series: MOVIDRIVE modular Multi-Axis Inverter (MDX91A)
- Module type: Multi-axis application inverter, book-style control-cabinet unit
Electrical Specifications
- Supply voltage: 3 x AC 380-500 V nominal, 50-60 Hz
- Line frequency tolerance: 50-60 Hz ±5%
- Nominal line current: 159.0 A
- Rated output current: 177.0 A at f_PWM = 4 kHz
- Recommended motor power (ASM): 90 kW
- Apparent output power S_N: 110.7 kVA
- Overload capacity: 200% of I_N at 4 kHz PWM; continuous 100% x I_N at 4 kHz PWM
- Continuous output current at 0 Hz: 159 A (I_N x 0.9)
- PWM frequency: 4 kHz and 8 kHz
- Max output frequency: U/f 599 Hz; VFCplus 250 Hz; CFC 500 Hz; ELSM 500 Hz
- Nominal DC link voltage: DC 560 V
- Minimum braking resistance R_BRmin: 2.3 Ω
- Brake chopper continuous power: 110.7 kW; peak power 200% x S_N
- Power section nominal power loss: Not published by manufacturer for this frame size
- EMC variant: Basic interference suppression integrated
Control and Communication
- Control modes:
- U/f
- VFCplus
- CFC (field-oriented current controller)
- ELSM (extended synchronous motor control)
- Built-in system bus: EtherCAT / CiA402 (MOVIDRIVE technology variant, fieldbus control)
- Fieldbus option cards:
- /CFN21A PROFINET IO
- /DFE32B EtherNet/IP
- /DFI11B PROFIBUS DPV1
- Communication expansion cards:
- /CES11A multi-encoder
- /CID21A encoder interface
- /CIO21A I/O expansion
- /CS..A MOVISAFE safety card
- /L conformal-coated PCB
Environmental Tolerance and Interference Resistance
- Operating temperature: 0 to +40 °C without derating; +40 to +60 °C with derating
- Storage temperature: -25 to +70 °C (EN 60721-3-1 class 1K2, non-condensing)
- Transport temperature: -25 to +70 °C (EN 60721-3-2 class 2K3, non-condensing)
- Relative humidity: Non-condensing, no moisture condensation (EN 60721-3-3 class 3K3)
- Protection rating: IP10; optional IP20 with plastic terminal covers
- Pollution class: 2 (IEC 60664-1); overvoltage category III
- Installation altitude: Up to 1000 m without restriction; 1000-3800 m with I_N derating 1% per 100 m
- Interference resistance: Basic EMC interference suppression integrated
Hardware and Physical Data
- Frame size: 7
- Operation: 4-quadrant
- Integrated DC 24 V auxiliary power supply: 80 W, can be supplemented externally
- Integrated brake chopper: Yes; optional braking resistor BR..
- Line/motor terminals: M10 copper busbars
- Dimensions (H×W×D): Not published as a numerical table; see product manual section 2.7 dimension drawings
- Weight: Not published as a numerical table; shown in dimension drawings per size
Installation Guide
- Mount the MDX91A-1770-503-4-T00 vertically in a control cabinet with frame size 7 clearance.
- Use M10 copper busbars for line and motor connections.
- Keep the DC 24 V auxiliary supply within its 80 W limit, or add an external supply.
- Respect IP10 protection; add plastic terminal covers to reach optional IP20.
- Follow derating rules above +40 °C and above 1000 m altitude.
- Connect the braking resistor BR.. if braking energy must be dissipated.
Commissioning and Maintenance Convenience
- Control mode flexibility: One unit covers U/f, VFCplus, CFC and ELSM, so setup adapts to the motor type.
- Fieldbus control: Built-in EtherCAT / CiA402 support simplifies commissioning in networked systems.
- Option cards: Encoder, I/O and safety cards install via slots, so upgrades do not replace the inverter.
- Conformal coating option: /L PCB coating supports use in harsh environments with less maintenance risk.
- Diagnostics: MOVIDRIVE technology variant supports fieldbus-based monitoring and parameter access.
Compatibility Notes
- Works with SEW-EURODRIVE MOVIDRIVE modular system components and the MOVI-C platform.
- Matches 3~AC 380-500 V, 50-60 Hz supplies with ±5% frequency tolerance.
- Recommended for 90 kW ASM motors and synchronous motors via ELSM.
- Fieldbus cards support PROFINET IO, EtherNet/IP and PROFIBUS DPV1 networks.
- Encoder interfaces cover multi-encoder and single-encoder feedback options.
Certifications and Standards
- Pollution class 2 per IEC 60664-1; overvoltage category III.
- Storage per EN 60721-3-1 class 1K2; transport per EN 60721-3-2 class 2K3.
- Humidity per EN 60721-3-3 class 3K3.
- Safety card option /CS..A MOVISAFE supports machine safety functions.
Packing List
- MDX91A-1770-503-4-T00 inverter unit, frame size 7, 1 pc
- Product manual reference and dimension drawing note, 1 set
- Plastic terminal covers only if IP20 option ordered
- Braking resistor BR.. and fieldbus/encoder cards only if ordered
FAQ
Q: What is the rated output current of this inverter?
A: It delivers 177.0 A at 4 kHz PWM. Continuous current at 0 Hz is 159 A.
Q: Can I use it on a 400 V line?
A: Yes. The range is 3~AC 380-500 V, 50-60 Hz, with ±5% frequency tolerance.
Q: Which motor control modes are available?
A: U/f, VFCplus, CFC and ELSM. This covers standard induction and synchronous motors.
Q: Does it include a brake chopper?
A: Yes. A brake chopper is integrated, and you can add an optional BR.. resistor. Minimum resistance is 2.3 Ω.
Q: How do I connect it to PROFINET?
A: Add the /CFN21A option card. EtherNet/IP uses /DFE32B, and PROFIBUS uses /DFI11B.
Q: What happens at high altitude?
A: Up to 1000 m no derating applies. Above 1000 m, derate I_N by 1% per 100 m up to 3800 m.
Q: Is IP20 available?
A: Yes. Add plastic terminal covers to raise protection from IP10 to IP20.
Q: From experience, what should I check first during commissioning?
A: Verify the DC 24 V auxiliary load stays under 80 W. Then confirm bus wiring and motor rotation direction before full load.
Q: What do field engineers often overlook?
A: The derating above +40 °C and the R_BRmin value. A resistor below 2.3 Ω can stress the brake chopper.
Q: Can I upgrade encoders later?
A: Yes. The /CES11A and /CID21A cards add encoder interfaces without replacing the inverter.















There are no reviews yet.