Product details
Product Overview
The Fujikin FCST2150 is a high-flow digital mass flow controller. It belongs to the FCST T2150 Series. This unit handles 51 to 150 SLM of N2 equivalent flow. A solenoid actuator drives the diaphragm valve. The valve is normally closed. A metal seal with a gold gasket protects gas purity. The body uses SUS316L stainless steel. This model suits high-flow semiconductor gas delivery, CVD chamber purge, and bulk gas distribution. The FCST2150 delivers ±2% FS accuracy and ±0.2% FS repeatability. Response time stays within one second. The design is compact and RoHS compliant. It also carries CE marking. Choose this model for stable, high-flow control in reactive gas lines.
Technical Specifications
- Brand: Fujikin
- Model: FCST2150
- Series: FCST T2150 Series (FCS-T2150 High Flow Piezo/Solenoid)
- Full-scale flow range: 51 to 150 SLM (N2 equivalent)
- Accuracy: ±2% FS
- Repeatability: ±0.2% FS
- Response time: ≤1 second
- Control range: 2 to 100% FS
- Gas types: N2, Ar, He, and semiconductor process gases
- Operating pressure: max 400 kPaG
- Required differential pressure: 200 to 350 kPa (51 to 100 SLM), 250 to 350 kPa (101 to 150 SLM)
- Proof pressure: 1 MPaG
- Wetted materials: SUS316L stainless steel, PCTFE, FKM
- Seals: metal seal with Au gold gasket
- Valve type: solenoid actuator, diaphragm valve, N/C only
- Electrical interface: analog 0 to 5 VDC, ±15 VDC supply
- Power draw: +15 VDC approx. 100 mA, -15 VDC approx. 200 mA
- Operating temperature: 5 to 50°C
- Heated option: no, standard unheated version
- Dimensions: 136 (H) x 163.4 (W) x 108 (D) mm
- Fittings: 3/8 UJR
- External leak integrity: ≤1×10⁻¹¹ Pa·m³/s He
- Surface finish: EP surface finish
Key Performance Notes
- Measurement range: wide 51 to 150 SLM span covers most high-flow tools.
- Frequency response: full stroke settles in one second or less.
- Linearity and sensitivity: ±2% FS accuracy supports repeatable process recipes.
- Resolution: 2 to 100% FS control range gives fine low-end trim.
- Temperature range: 5 to 50°C suits cleanroom and cabinet installs.
- Environmental tolerance: proof pressure of 1 MPaG adds safety margin.
- Noise immunity: analog 0 to 5 VDC signal works with shielded cabling.
Installation Guide
- Mount the FCST2150 in any stable orientation.
- Keep the unit level for best zero stability.
- Use 3/8 UJR fittings for leak-tight joints.
- Confirm differential pressure before power-up.
- Set 200 to 350 kPa for flows of 51 to 100 SLM.
- Set 250 to 350 kPa for flows of 101 to 150 SLM.
- Wire ±15 VDC to the correct pins.
- Route the analog signal away from power cables.
- Purge the line with dry N2 before first run.
- Check for external leaks after assembly.
Setup and Maintenance
- Zero the analog output at no flow.
- Calibrate against a certified flow standard.
- Log drift values during scheduled checks.
- Replace the Au gold gasket at service intervals.
- Keep the metal seal free of particles.
- Use dry, oil-free gas only.
- Store spare parts in clean bags.
- The compact body eases in-cabinet access.
Compatibility
- Works with standard 0 to 5 VDC analog controllers.
- Fits 3/8 UJR gas panels and manifolds.
- Handles N2, Ar, He, and common semiconductor gases.
- Matches Fujikin T2000 series gas panel layouts.
- Pairs with EP-finish tubing for purity loops.
Certification and Compliance
- RoHS compliant.
- CE marked.
- EP surface finish for high-purity service.
Packing List
- One Fujikin FCST2150 mass flow controller.
- One calibration certificate.
- One quick start guide.
- One fitting kit for 3/8 UJR ports.
- One protective cap set.
FAQ
- Q: Can I run this unit at 150 SLM with low inlet pressure?
A: No. You need 250 to 350 kPa differential pressure at that flow. - Q: Is the valve normally open?
A: No. The FCST2150 ships as N/C only. - Q: Does it come with a heater?
A: No. This is the standard unheated version. - Q: How often should I check zero drift?
A: Most fabs check monthly during the first year. - Q: What causes slow response in the field?
A: A clogged inlet filter or low differential pressure is the usual cause. - Q: Can I swap this unit with a T2000 low-flow model?
A: Check pressure and fitting match first. Flow span differs. - Q: Why does my reading drift after a gas change?
A: Gas correction factors differ. Recalibrate for the new gas. - Q: What is the most common install mistake?
A: Reversed flow direction and unshielded signal wiring.