Product details
FCST2005 Fujikin Piezo Actuator Flow Controller for Reactive Gases
The FCST2005 from Fujikin belongs to the FCST T2000 Series. It is a piezo-actuated flow controller built for high-reactivity and low-stability gases. The diaphragm valve uses a gold-gasketed metal seal. This design limits particle generation and suits demanding semiconductor processes. The unit covers 5 SCCM to 5 SLM (N2 equivalent). A special 1-3 SCCM micro-flow option is also available. Accuracy reaches ±1% S.P. across 25-100% of set point. Analog 0-5 VDC and digital RS-485 or DeviceNet interfaces support easy integration. The standard version ships unheated for ambient operation.
Technical Data
- Brand: Fujikin
- Model: FCST2005
- Series: FCST T2000 Series (FCS-T2000 Piezo Actuator)
- Full-scale flow range: 5 SCCM to 5 SLM (N2 equivalent)
- Accuracy: ±1% S.P. (25-100% of set point); ±0.25% FS (2-25%)
- Repeatability: ±0.2% FS
- Response time: ≤1 sec
- Control range (turndown): 2-100% FS
- Operating pressure: Max 300 kPaG; required differential pressure 50-300 kPa; proof pressure 1 MPaG
- Wetted materials: SUS316L stainless steel, PCTFE
- Seals: Metal seal (Au gold gasket)
- Valve type: Piezo actuator diaphragm valve, N/O or N/C
- Electrical interface: Analog 0-5 VDC (±15 VDC supply); Digital RS-485, DeviceNet
- Power supply: ±15 VDC; +15 VDC approx. 100 mA, -15 VDC approx. 50 mA
- Operating temperature: 5-50°C
- Heated option: No (standard unheated version)
- Dimensions: 131 (H) × 124 (W) × 71 (D) mm
- Leak integrity: ≤1×10⁻¹¹ Pa·m³/s He (external leak)
- Gas types: O3, halogen and reactive process gases; N2, Ar, He, H2 and semiconductor gases; special 1-3 SCCM micro-flow option
- Compliance: RoHS compliant; CE; EP surface finish
Key Performance Notes
- Measurement range: 5 SCCM to 5 SLM covers micro and standard flows.
- Response: Settles within one second for fast process steps.
- Linearity and repeatability: ±1% S.P. accuracy and ±0.2% FS repeatability give stable dosing.
- Resolution: Wide 2-100% FS control range supports fine adjustment.
- Temperature range: 5-50°C suits cleanroom and cabinet installs.
- Environmental tolerance: Metal seals and SUS316L resist corrosive and oxidizing media.
- Interference resistance: RS-485 digital signaling limits noise pickup in tool racks.
Installation Guide
- Mount the unit on a clean, dry gas panel. Keep the base flat.
- Keep differential pressure between 50 and 300 kPa for stable control.
- Do not exceed 300 kPaG operating pressure or 1 MPaG proof pressure.
- Use compatible fittings. Flush lines before connection.
- Wire the ±15 VDC supply with correct polarity.
- Connect RS-485 or DeviceNet for digital control.
- Purge with dry N2 before reactive gas service.
Setup and Maintenance Ease
- Zero and span checks run quickly through the analog interface.
- RS-485 allows remote setup and diagnostics.
- Metal-sealed diaphragm design reduces wear parts.
- Few components mean short service downtime.
- No heater keeps cabling and service simple.
- EP surface finish supports particle-sensitive lines.
Compatibility Notes
- Works with O3, halogens, and other reactive process gases.
- Handles N2, Ar, He, H2, and common semiconductor gases.
- Supports analog 0-5 VDC and digital RS-485 or DeviceNet hosts.
- Fits CVD, etch, flat panel display, and solar panel tools.
- PCTFE and SUS316L wetted parts match most corrosive gas lines.
Certification Information
- RoHS compliant for restricted substance limits.
- CE marked for European market use.
- EP surface finish for high-purity gas paths.
- External leak rate meets ≤1×10⁻¹¹ Pa·m³/s He.
Packing List
- 1 × FCST2005 flow controller
- 1 × calibration certificate
- 1 × operation manual
- 1 × connector kit for power and signal
- 1 × protective port caps
FAQ
Q: Which gases can this controller handle?
A: It suits O3, halogens, and reactive process gases. It also works with N2, Ar, He, H2, and common semiconductor gases.
Q: What flow range does the FCST2005 cover?
A: The standard range is 5 SCCM to 5 SLM (N2 equivalent). A 1-3 SCCM micro-flow option exists for low-flow work.
Q: How accurate is the dosing?
A: Accuracy is ±1% S.P. from 25-100% of set point. From 2-25% it is ±0.25% FS. Repeatability is ±0.2% FS.
Q: Does it need a heated jacket?
A: No. The standard FCST2005 is unheated and runs at 5-50°C.
Q: What pressure does it need?
A: Keep differential pressure between 50 and 300 kPa. Maximum operating pressure is 300 kPaG.
Q: How do I connect it to my tool?
A: Use the analog 0-5 VDC interface or digital RS-485 or DeviceNet. Supply is ±15 VDC.
Q: What does field experience show about uptime?
A: Users report stable control in O3 and etch lines. The metal seal and piezo drive limit drift. Most sites schedule annual zero checks and seal inspection.
Q: How do I handle a reactive gas line safely?
A: Purge with dry N2 before and after reactive service. Verify leak integrity at ≤1×10⁻¹¹ Pa·m³/s He before restart.















There are no reviews yet.