Product details
Product Overview
- FCST1030ZF is a digital mass flow controller from Fujikin.
- It belongs to the FCST T1000 Series (FCS-T1000Z MGMR).
- The unit covers 3,001 to 30,000 SCCM full-scale flow (N2 equivalent, Bin 6-7).
- MGMR design stores up to 8 gas and flow tables in one body.
- Ranges span 10 SCCM to 50 SLM across those tables.
- Accuracy holds at ±1% of set point from 25 to 100% SP.
- Low-end accuracy is ±0.25% of full scale from 2 to 25%.
- Response time stays at or under 1 second.
- The Hastelloy C sensor resists halogen and corrosive gases.
- Gas tables cover N2, Ar, He, H2, O2, SiH4, CH4, SF6, Cl2 and NH3.
- The body fits CVD, PVD, etching and diffusion tools.
- It also suits gas cabinets and thin-film deposition lines.
- This is the standard unheated version.
Technical Data
- Brand: Fujikin
- Model: FCST1030ZF
- Series: FCST T1000 Series (FCS-T1000Z MGMR)
- Module type: Digital mass flow controller with MGMR
- Full-scale flow range: 3,001 to 30,000 SCCM (N2 equivalent, Bin 6-7)
- Accuracy: ±1% S.P. (25-100% of set point); ±0.25% FS (2-25%); guaranteed 15-35°C
- Repeatability: ±0.2% FS
- Frequency response: at or under 1 second
- Control range / turndown: 2-100% FS
- Linearity: folded into the ±1% S.P. accuracy spec
- Sensitivity: Hastelloy C sensor holds signal in corrosive gas
- Resolution: digital control across 8 gas and flow tables
- Gas type: multi-gas/multi-range (MGMR); up to 8 tables from 10 SCCM to 50 SLM
- Gases: N2, Ar, He, H2, O2, SiH4, CH4, SF6, Cl2, NH3 and other process gases
- Operating pressure: max 400 kPaG (Ar: 500 kPaG)
- Differential pressure: 50-300 kPa required
- Operating temperature: 5-50°C
- Environmental resistance: EP surface finish on metal type
- Interference resistance: metal seal blocks outside contamination
- Wetted materials: SUS316L stainless steel, Hastelloy C sensor, PCTFE seats
- Seals: metal seal (M) or rubber FKM (F); order code sets the type
- Valve type: bellows-sealed diaphragm valve (N/O or N/C)
- Leak integrity: at or under 1×10⁻¹¹ Pa·m³/s He (metal); at or under 1×10⁻⁷ Pa·m³/s He (rubber)
- Dimensions: 125 (H) × 124 (W) × 77 (D) mm
- Power supply: ±15 VDC (0-5 VDC analog); +24 VDC (0-5 VDC or 4-20 mA)
Electrical Interface and Compatibility
- Analog: 0-5 VDC (±15 VDC or +24 VDC)
- Current loop: 4-20 mA (+24 VDC)
- Digital: RS-485, DeviceNet, EtherCAT (metal seal only)
- Compatibility: field gas and range changes run through setup software
- One body can cover several tools, which trims spare stock.
- Check the seal type before you pick a digital bus option.
Installation Guide
- Keep inlet pressure at or below 400 kPaG; Ar up to 500 kPaG.
- Set the pressure drop between 50 and 300 kPa.
- Flush the line before you fit the controller.
- Match the gas table to the line gas before startup.
- Tighten fittings to the maker’s torque values.
- Wire power and signal lines per the chosen option.
- Run a zero check after warm-up and before the first run.
Setup and Maintenance
- MGMR software lets you change gas and full-scale flow on site.
- You swap a table instead of a whole unit.
- The Hastelloy sensor cuts corrosion damage in halogen service.
- Metal seals suit ultra-clean lines; rubber seals suit general duty.
- Keep gas dry and clean to protect seats and the sensor.
- Check zero and span at each service visit.
- Log each table change for faster future setup.
Certification and Packaging
- Compliance: RoHS compliant; CE
- Surface finish: EP finish on the metal type
- Packaging list: one FCST1030ZF mass flow controller
- One setup software and wiring guide
- One calibration certificate
- Fitting hardware as ordered
- Seal and interface options ship per order
FAQ
- Can I change the gas after the unit ships?
- Yes. MGMR software lets you switch tables on site.
- How many gas and flow tables fit in one body?
- Up to 8 tables, from 10 SCCM to 50 SLM.
- How fast does the flow settle?
- It settles in 1 second or less.
- Which seal should I pick for chlorine service?
- Choose the metal seal and the Hastelloy sensor option.
- Can I use EtherCAT with a rubber seal unit?
- No. EtherCAT needs the metal seal type.
- What pressure drop does the valve need?
- Keep the drop between 50 and 300 kPa.
- In practice, what saves the most time during a tool change?
- Save each gas table as a file and reload it fast.
- What causes most accuracy drift in the field?
- Low differential pressure and dirty gas cause most drift.
- How do I spot a seal leak early?
- Watch for rising zero offset or slow shutoff at the valve.